View:


PR1MA™ Mini Gel Electrophoresis System

 

  • Complete system, includes gel box, power supply and casting sets
  • Quick and easy gel casting, no tape, clamps or spacers required
  • Compact design, footprint: 7 x 5.1 in.

 

The PR1MA™ Mini Gel electrophoresis system includes all of the equipment that you need to get up and running: gel tank, power supply, and two casting sets. Ideal for personal use, small laboratories, or the classroom, this gel box/power supply combination is compact and easy to use.

The mini gel box attaches directly to the power supply for a secure connection every time. Selectable parameters include 3 preset voltages – 35V, 50V or 100V – and a 99-minute timer. All are set using the membrane keypad.

 

The safety lid is vented to help dissipate heat generated during electrophoresis and features a viewing area above the gel. Current will only run through the system when the lid is properly in place on top of the gel box.

 

Trays and casting stands for both 10.5 x 6 cm and 5 x 6 cm gels are included with the PR1MA™ Mini system, as are double-sided combs. The smaller tooth combs are compatible with multi-channel pipettes. Casting is quick and easy – just place the tray in the casting stand and pour. The trays feature a dark contrast strip to help visualize wells while loading and lines that fluoresce under UV and blue light to track the progress of the run.

 


Specifications

Output Voltage35V, 50V or 100V
Timer0-99 min. or Continuous
SafetyLid interlock
Max. Buffer230 mL
Gel CapacityOne: 10.5 x 6 cm 
Two: 5 x 6 cm
Weight1 lbs | 0.45 kg
Dimensions7.5 x 5.1 x 2.1 in
Electrical115V or 230V, 50-60 Hz



 

Item#:
ASPCRELCTP25

myGel InstaView™ System | Complete System with Power Supply

  • View DNA migration and separation as it happens
  • Blue light illumination - won't damage DNA
  • Capture high-resolution images without removing the gel from the tank

The myGel InstaView comes complete with everything needed to cast, run, and view mini electrophoresis gels, including an integrated power supply. One large (10.5 x 10 cm) or small (10.5 x 6 cm) gel is accommodated by the gel tank. Gels are easily poured using the supplied trays, combs, and leak-proof casting stand. The power supply connects directly to the gel tank – no more leads to contend with. The connection is guaranteed to be right, every time.

 

Output voltage can be adjusted to 35V, 50V, or 100V and run time can be set for up to 99 minutes. A magnetic interlock between the gel tank and the lid prevents current from running through the system when the lid is not properly in place.

 

Once the myGel InstaView System is set up, simply slide the mini LED transilluminator into place under the tank and at any time turn it on to view the run in real-time. An array of blue LEDs emits bright blue light at a wavelength of 465 nm for optimal excitation of common green fluorescent stains such as SmartGlow, SYBYR Green, and Gel Green, without damaging DNA. An orange filter is incorporated into the lid for visualizing DNA bands without any additional equipment or special glasses. When it’s time to document results, place the included gel imaging enclosure over top of the myGel InstaView, and use the camera app on any smartphone to capture high-resolution images without removing the gel from the tank.

Images are easily shared via email or text message or printed.
 

Specifications

Output voltage35 V, 50 V or 100 V
Timer0-99 mins, continuous
SafetyMagnetic switch
Buffer Volume230 mL
Gel Capacity1-10.5 x 10 cm or 1-10.5 x 6 cm gel, 0.5 cm thick
TransilluminatorBlue LED, 465 nm
WxDxH (w/enclosure)10 x 8.25 x 5 in/25.5 x 21 x 14 cm
Weight2.3lb/1.04kg
Electrical115V, 60Hz or 230V, 50Hz
Warranty2-year

 

 

InstaView Gel Tank

 

For labs that prefer to use a separate power supply, the InstaView Gel Tank is the perfect choice for running, viewing, and documenting electrophoretic separations. The InstaView Gel Tank accommodates one large (10.5 x 10 cm) or one small (10.5 x 6 cm) gel tray and is supplied with trays, combs, and a leak-proof casting stand. The gel tank lid includes attached power leads which prevent the unit from operating without the lid properly in place.

 

Any standard power supply can be connected, including the Accuris myVolt Mini and myVolt Touch. The InstaView Gel Tank is shaped to allow the mini-LED transilluminator (included) to slide underneath. Blue light, at a wavelength of 465 nm, provides excitation of common green fluorescent stains such as SmartGlow, SYBR Green, and GelGreen. An orange filter is incorporated into the gel tank lid for visualizing the DNA in the gel box without any additional equipment or glasses. The transilluminator can be turned on at any time during a run to track progress and automatically shuts off after 5 minutes.

 

After electrophoresis, simply place the included imaging enclosure over the InstaView Gel Tank to capture high-resolution images with a smartphone. Images are easily printed or shared via email or text message.

 

Specifications 
SafetyPhysical interlock between lid and tank
Buffer Volume230 mL
Gel Capacity1-10.5 x 10 cm or 1-10.5 x 6 cm gels, 0.5 cm thick
TransilluminatorBlue LED, 465 nm
WxDxH (w/enclosure)7.5 x 8.25 x 5 in /19 x 21 x 14 cm
Weight1.65lb/0.75kg
Electrical115V, 60Hz or 230V, 50Hz
Warranty2-year

  

System & Accessories

E1201myGel InstaView™ Complete Electrophoresis System with Blue LED Illuminator
E1200myGel InstaView™ Gel Tank with Blue LED Illuminator
E1200-CS1Extra casting set for 10.5 x 10 cm and 10.5 x 6 cm gels. Includes stand, trays, E1101-COMB1 double-sided combs
E1101-COMB1Extra double-sided combs, 22/12 teeth, for E1200-CS1 Casting Set, pk of 2
E1200-OCOrange filter cover for mini LED transilluminator
E4000-VG1SmartView Viewing Glasses
Item#:
ASMYGELINST

Double sided water cooled vertical system, 10cm x 10cm


Reflection double sided water cooled vertical system, 10cm x 10cm with or without casting base, two pack each of plain and notched glass, one acrylic blocker plate, (2) 10-well 0.8mm thickness combs, (4) 0.8 mm spacers. Four year warranty.

System Description
 
Run either one or two gels simultaneously on these versatile separation systems. The 10x10cm size of the system also accomodates most pre-cast gels.

Complete double sided vertical system for running one or two gels, in a 10 x 10 cm format. Unique casting bases allows both casting and running of gels without unclamping from the upper buffer chamber, providing for safer and more convenient gel handling. In addition the 1010 device will accommodate most precast gel cassettes on the market.

Water cooling feature is included for protocols that require it. Connections are easily made by attaching standard tubing over the 3/8" barbed in/out ports provided on the device. Water may be provided by tap or other temperature controlled water source. Optional alumina backer plates may be used to facilitate cooling efficiency and uniformity, and are available in the accessories list below.

System Features
 
The Galileo Reflection™ 85-1010 complete system includes these features:

  • Heavy duty upper buffer chamber with cooling port connections.
  • Lower buffer chamber.
  • Interlock safety lid with attached leads.
  • Casting base.
  • Two-pack each of plain & notched glass plates.
  • One acrylic blocker plate (used when running only one gel).
  • Ttwo 10-well, 0.8mm thick combs
  • Four 0.8mm thick side spacers.
  • System Accessories
  • Choose amoung these accessories to customize each system for your specific needs.
  • Alumina cooling plate.
  • For use with cooling systems.
  • This plate can be sandwiched between the gel and the inner buffer chamber to improve overall temperature uniformity.
  • Casting base.
  • For quick, efficient and leak-proof casting.
  • Multiple gradient caster.
Item#:
ASDOUBSIDEWAT10C

Extra Wide Large Format Gel System, 23.5cmW x 40cm

 
Extra wide large format gel system, 23.5cmW x 40cmL gel size with buffer exchange ports, UVT gel tray with fluorescent ruler and 12 tray slots, (2) 25 teeth combs, 1.5 mm thickness and (2) 50 teeth combs, 1.5 mm thickness.
System Description

For long run lengths, maximum resolution, and really large sample capacity, look no further than the Galileo 2340 device. This unit also features the Galileo ExpressCast system for quick tape-less gel pouring.

The 2340 is our maximum capacity system. With a maximum run length of 25cm, the unit can provide very high resolution of complex analytes. Or, fitted with maximum capacity combs in all of the tray's 12 comb slots, the unit can handle up to 600 samples. The 2340 features the Galileo ExpressCast gel casting system for quick, tape-free gel casting and includes a built-in bubble level and leveling screws for convenient level adjustment. You may choose from a wide variety of comb options to customize your order.
System Features

The Galileo 2340 complete system includes these features:

  •     Heavy duty lower buffer chamber
  •     Interlock safety lid with attached leads
  •     End gated 23cm wide x 40cm long ExpressCast™ UV-transparent gel tray with built-in fluorescent ruler and 12 comb slots.
  •     Two 1.5mm x 25 tooth combs
  •     Two 1.5mm x 50 tooth combs
Item#:
ASEXTRAWIDELGFOR23

Extra Wide Format Gel System, 23.5cmW x 25cmL


 ExpressCast extra wide format gel gystem for 23.5cmW x 25cmL gel size. Includes UVT gel tray with fluorescent rulers and 14 comb slots, (2) 25 tooth combs, 1.5 mm thickness, and (2) 50 tooth combs, 1.5 mm thickness and gasketed end-gates.
System Description

Need long run lengths for maximum resolution, and large sample capacity too? Look at the features of the Galileo 2325 unit and we think you will find just what you need.

The 2325 is a full sized large capacity system. With a maximum run length of 25cm, the unit can provide high resolution of complex analytes. Or, fitted for maximum capacity, the unit can handle up to 500 samples. The 2325 features the Galileo ExpressCast gel casting system for quick, tape-free gel casting and includes a built-in bubble level and leveling screws for convenient level adjustment. You may choose from a wide variety of comb options to customize your order.
System Features

The Galileo 2325 complete system includes these features:

  •     Heavy duty lower buffer chamber
  •     Interlock safety lid with attached leads
  •     End gated 23cm wide x 25cm long ExpressCast™ UV-transparent gel tray with built-in fluorescent ruler and 14 comb slots.
  •     Two 1.5mm x 25 tooth combs
  •     Two 1.5mm x 50 tooth combs
Item#:
ASEXTRAWIDEFOR23

Double sided water cooled vertical system, 20cmW x 10cm


The Galileo Bioscience Reflection 2010 is a wide, high capacity gel electrophoresis separation system that allows users to run up to two protein gels simultaneously on a 20 cm wide x 10 cm tall format.  The large gel format makes this unit ideal for users who have a large number of protein samples to run simultaneously.  Galileo's unique casting base allows users to both cast and run gels without ever having to unclamp the upper buffer chamber.  This makes handling gels safer and more convenient, especially for those who may be prone to ripping their gels between the two activities. 

The 2010 vertical gel box also includes a water cooling feature for electrophoresis protocols that require lower temperature.  This water can be provided by the tap or other temperature controlled source and is easily connected by attaching standard tubing over the 3/8" barbed in/out ports on the device.  Users may also facilitate cooling efficiency and uniformity using Galileo's optional alumina backer plates (see accessories below).

System Features

Each Reflection 85-2010-V vertical system includes the following features:

  • Heavy duty upper buffer chamber with cooling port connections
  • Lower buffer chamber
  • Interlock safety lid with attached leads
  • Casting base
  • Four-pack each of plain and notched glass plates
  • One acrylic blocker plate (used when only one gel is being run)
  • Eight 0.8mm thick side spacers
  • Four combs of your choice
  • System Accessories

Alumina cooling plate for use with cooling systems. This plate can be sandwiched between the gel and the inner buffer chamber to improve overall temperature uniformity.
 
Casting base for quick, efficient and leak-proof gel casting.
Item#:
ASDOUBLESIDEWATVER20

Double sided non cooled vertical system, 20cmW x 10cm


 The Galileo Bioscience Reflection 2010 is a wide, high capacity gel electrophoresis separation system that allows users to run up to two protein gels simultaneously on a 20 cm wide x 10 cm tall format.  The large gel format makes this unit ideal for users who have a large number of protein samples to run simultaneously.  Galileo's unique casting base allows users to both cast and run gels without ever having to unclamp the upper buffer chamber.  This makes handling gels safer and more convenient, especially for those who may be prone to ripping their gels between the two activities.

The 2010 vertical gel box also includes a water cooling feature for electrophoresis protocols that require lower temperature.  This water can be provided by the tap or other temperature controlled source and is easily connected by attaching standard tubing over the 3/8" barbed in/out ports on the device.  Users may also facilitate cooling efficiency and uniformity using Galileo's optional alumina backer plates (see accessories below).

System Features

Each Reflection 85-2010-V vertical system includes the following features:

  •     Heavy duty upper buffer chamber with cooling port connections
  •     Lower buffer chamber
  •     Interlock safety lid with attached leads
  •     Casting base
  •     Four-pack each of plain and notched glass plates
  •     One acrylic blocker plate (used when only one gel is being run)
  •     Eight 0.8mm thick side spacers
  •     Four combs of your choice

System Accessories

  •     Alumina cooling plate for use with cooling systems. This plate can be sandwiched between the gel and the inner buffer chamber to improve overall temperature uniformity.
  •     Casting base for quick, efficient and leak-proof gel casting.
Item#:
ASDOUBLESIDENONCO20

ENDURO VE20 Vertical Gel Electrophoresis System


Enduro VE20 Vertical Electrophoresis System (20 x 20 cm), includes glass plates, 2 x 24 well combs, cooling coil and casting base

  • Large format vertical gel system
  • Electroblotting and gel electrophoresis in same universal gel tank
  • Quick assembly system for ease of use
  • Complete system allows casting of gels and running of gels at same time increasing efficiency

The ENDURO VE20 is Labnet's new large format vertical gel electrophoresis system. It distinguishes itself in its flexibility of applications and ease of gel casting and set-up requiring only 4 screws to secure 4 gels. The same gel tank can house a large format electroblotting assembly sold separately. This system is ideal for first- and second dimension SDS-PAGE, native, preparative, gradient and high-resolution nucleic acid electrophoresis.


Innovative screw-clamp technology consists of only four screws to secure up to four 20 x 20cm gels. This vertical screw clamp technology distributes pressure evenly along the height of gel rather than in the center to eliminate plate bowing and gel compression, while maintaining a leak-proof seal during casting.

NO TANK TOP ASSEMBLY
A built-in inner buffer chamber within the PAGE insert allows set up to be completed without inclusion of an upper buffer chamber.

CASTING ADVANTAGES

  • Dual purpose PAGE insert eliminates time consuming transfer of glass plates between separate casting and gel running components.
  • Glass plates with bonded spacers assure clean well formation, correct alignment for leak-free casting and eliminates manually aligning spacers.
  • Casting stand design ensures leak-free casting even if glass plates are misaligned.

Specifications:


Plate Dimensions (w x h x t)

20 x 20 x 0.4 cm

Standard Spacer (w x h)

2 x 20 cm

IPG Spacer (w x h)

0.6 x 20 cm

Unit (w x d x h)

30 x 18 x 27 cm

Unit weight

5.5 lbs

Number of gels

4

Total volume inner buffer chamber

640 mL

Total buffer volume for 2 gels

5.3 L

Total buffer volume for 4 gels

4.8 L

Standard run time for SDS-PAGE without coolling

4-5 hr

Standard run time for SDS-PAGE with coolling

3-4 hr

 

Order#

Description

E2020

Enduro VE20 Vertical Electrophoresis System (20 x 20 cm), includes glass plates, 2 x 24 well combs, cooling coil and casting base

E2020-CU

Enduro VE20 Dual Casting System, includes 20 x 20 cm Dual, 2 sets of glass plates, 1 mm think bonded spacers, 2 x 24 sample, 1 mm thick combs, cooling coil, dummy plate; also includes caster and external casting

E2020-IEF

Enduro VE20 IEF Conversion Kit for 18 cm IPG strips and Tube gels

E2020-TB

Enduro VE20 Blotting System, 20 x 20 cm System Including tank and lid, 4 cassettes, 18 fibre pads, cooling coil

Item#:
ASPCRELCTP23

ENDURO™ Semi Dry Blotter

  • Western, Southern, and Northern Blots
  • Rapid transfer times
  • Uniform head dispersion
  • Variable gel thickness
  • Minimal buffer volume

The ENDURO™ Semi-Dry Blotter provides great flexibility in a lab since it can be used for all types of blotting: Western, Southern, and Northern. Blotting with the ENDURO™ Semi Dry Blotter typically can be done in 15 to 30 minutes making it a fast and easy way to do all your blotting applications. Set up procedures are easy and economical with little buffer needed. The screw down lid adjusts to varying gel thicknesses and sizes while the platinum coated electrodes provide uniform pressure ensuring even transfers. To provide your lab with total blotting solutions use with our ENDURO™ 250V, 3000mA high current power supply.


Specifications

Dimensions

32.5 x 25 x 5.5 cm | 12.8 x 9.8 x 2.2 in

Buffer Volume

20 mL

Sample Capacity

4 Blots: 8 x 8.5 cm | 2 Blots: 16 x 8.5 cm | 1 Blot: 16 x 17.5 cm

Item#:
ASDRYBLOT

Semi-Dry Blotting Systems, 10cm x 10cm


Choose Galileo Insight™ semi-dry sytems for rapid and efficient molecular transfer.
Galileo semi-dry electroblotters provide quick and efficient transfer of nucleic acids and proteins from agarose or acrylamide gels. Since only the tranfer "sandwich" of gel, membrane and blotting papers must be kept wet, much less buffer is required than traditional tank transfer systems. Solid plate style electrodes (stainless steel cathode and platinum anode) assure even and complete molecular transfer.

Item#:
ASSEMIDRYELECT1010

Wide Format Gel System 23.5 cm x 14 cm


 Horizontal Wide Format Gel System for 23.5cm x 14cm gels. Includes UVT gel tray four comb slots and end gates & (4) 50 Tooth combs, 1.5 mm thickness.
System Description

A high-capacity system in a mini-gel size, the Galileo 2314 unit enables rapid separation of large numbers of samples.

The 2314 wide format system accomodates up to 200 samples per run, for quick separation and high thru-put. Because of the wide format of the Galileo 2314 unit, the 23cm wide by 14cm long tray is non-gasketed. Gel casting can be accomplished by taping, or we recommend the G-80-WADJ-CST multi-casting unit for even quicker and more convenient gel casting. The gel tray is UV transmissible, includes an imprinted fluorescent ruler, and has 4 comb slots. Choose from a wide variety of comb options, all with micro-titer spacing for easy loading with multi-channel pipets.
System Features

The Galileo 2314 complete system includes these features:

  •     Heavy duty lower buffer chamber
  •     Interlock safety lid with attached leads
  •     Non-gasketed 23cm wide x 14cm long UV-transparent gel tray with built-in fluorescent ruler and 4 comb slots.
  •     Four 1.5mm x 50 tooth combs
  •     Opaque well visualization plate.
Item#:
ASWIDEFORGELSY23

Minigel System 9cm x 11cm & (1) 10 and (1) 14 tooth comb


Horizontal gel electrophoresis minigel system for 9cm x 11cm minigels. Includes gasketed UVT gel tray with fluorescent ruler, and (1) 10 and (1) 14 tooth comb, 1.5 mm thickness. Comb substitutions are available. Four year manufacturer warranty.

System description

The standard 0911 mini gel system includes a RapiCast™ gasketed gel tray for convenient gel casting right in the buffer chamber.

System features

The 0911 complete system includes these features:

  •     Heavy duty lower buffer chamber
  •     Interlock safety lid with attached leads
  •     Gasketed (cast in place) 9cm wide x 11cm long UV-transparent gel tray with built-in fluorescent ruler and 2 comb slots.
  •     One 1.5mm x 10 tooth comb
  •     One 1.5mm x 14 tooth comb
Item#:
ASMINGEL9AND11S
View: