S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Minigel System w/ 4 comb slots, 12 cm x 14 cm
Horizontal gel electrophoresis system for 12cm x 14cm minigels. Includes gasketed UVT gel tray with fluorescent ruler, and (1) 12 and (1) 20 tooth comb, 1.5 mm thickness. Comb substitutions are available. Four year manufacturer warranty.System Description
This flexible system from Galileo is the perfect personal unit for a wide range of separation needs, and our most popular model.
Unit features RapidCast trays for quick in-unit gel casting of 12cm wide by 14cm long gels.
Choose a complete system or build your own custom unit from the many system components we offer. The NEBT-80-1214 gel system is supplied with a RapidCast™ gasketed gel tray for convenient gel casting directly in the buffer chamber. Choose from a wide variety of comb options. All are compatible with Owl Separation Systems B2A or similar devices. The teeth on combs marked as "microtiter" are uniformly spaced for easy loading with multichannel pipettors.System features
System Features
The Galileo 1214 complete system includes these features:
- Heavy duty lower buffer chamber
- Interlock safety lid with attached leads
- Gasketed (cast in place) 12cm wide x 14cm long UV-transparent gel tray with
- built-in fluorescent ruler and 2 comb slots.
- One 1.5mm x 12 tooth comb
- One 1.5mm x 20 tooth comb
System Options
The Galileo 1214 unit can be also be ordered with our new automatic buffer recirculation system (80-1214-R) or with installed buffer ports for connection to an external buffer recirculation system (80-1214-BEP)
Electrophoresis System Bundle
Package Includes:
- Complete PR1MA™ myGel™ Mini system (E1101; includes gel box, power supply, and casting sets)
- SmartDoc™ 2.0 Gel Viewing and Smart Phone Imaging System (E5001-SDB)
- SmartGlow DNA Stain, 1.0 mL (BE4500-PS or BE4500-LD)
- Agarose LE, 100 grams
Horizontal Gel System, 15cmW x 25cmL
Galileo large gel systems are designed for high resolution of complex analytes. All units feature long run lengths, with medium to high capacity units available. High quality 9mm thick rugged acrylic construction, resists cracking and warping.
Your safety ensured with interlocking lid, protected sockets and permanently attached power cords. Epoxy sealed electrode connections, resist corrosion and leaks. Gold plated banana plugs.
Meets or exceeds IEC1010-1 standards. Safe & Reliable UV transmissible gel trays with built-in fluorescent rulers.
Large units feature trays with multiple comb slots for veratility. Machined finger grooves on the tray sides for easy and sure handling. Wide range of comb configurations, including multi-channel capability. Selected units available with buffer recirculation capabilities. Combs specifications clearly marked on each comb. Optional casting methods for flexibility, convenience and speed.
Convenient & Versatile
- Exceptional resolution.
- Platinum electrodes configured to provide uniform field for straight runs.
- Multiple comb slot options for a wide range of sample and run-length configurations.
Buffer volume: 1200ml
The IB56000 HR2025 is a high resolution system ideal for separation of nucleic acids in agarose gels. It is also designed for rapid screening of PCR fragments, RFLP analysis or
plasmid screening, field inversion, genomic DNA separations and electrophoresis procedures requiring recirculation. Constructed of 3/8" cast acrylic to provide years of
trouble-free service. Withstands high voltage and high temperatures and will not warp or crack like molded units do.
This System Comes Complete with:
- Buffer Tank
- Patented Vented Lid
- IB56020 UVT Casting Tray
- IB56030 Casting Fixture
- Two, 2.0mm x 20-tooth combs
- Power Cords
- Bubble Level
- Buffer Ports
- 4 year warranty
Specifications: |
Unit Dimensions: 8.3cm(H) x 26.7cm(W) x 39.4cm(L) |
Gel Dimensions: 20cm x 25cm |
Maximum sample capacity: 160 samples (4 combs, 40 samples each) |
Buffer Capacity: 1200ml |
Distance between electrodes: 35cm |
Buffer volume: 1500ml
This high throughput system is designed to complete analysis of up to 200 samples
from microtiter plates and is ideal for running all types of precast gels. The large format
can run gels in less than 30 minutes.
Specifications: |
Unit Dimensions: 8.3cm(H) x 26.7cm(W) x 39.4cm(L) |
Gel Dimensions: 25cm x 25cm |
Maximum sample capacity: 300 samples (6 combs, 50 samples each) |
Buffer Capacity: 1500ml |
Distance between electrodes: 35cm |
This System Comes Complete with:
- Buffer Tank
- Patented Vented Lid
- IB57020 UVT Casting Tray
- IB57030 Casting Fixture
- Four, 2.0mm x 50-tooth combs
- Power Cords
- Bubble Level
- Buffer Ports
- 4 year warranty
Gel Size: 10cm(W) x 15cm(L)
Buffer volume: 500ml
The MP-1015 is the ideal Multi-Purpose gel box for both extended high resolution, linear runs, and economical quick screens. The MP-1015 contains buffer recirculation ports for long runs requiring recirculation. The MP-1015 is constructed of 3/8" thick, cast acrylic, to withstand high voltages and temperature extremes. Unlike single piece molded units, the MP1015 will NOT warp or crack during extended use. This unit is designed to provide years of continuous operation.
Specifications: |
Construction: Buffer tank is constructed of 3/8" thick, cast acrylic. Casting tray bottom is constructed of UV transmittance cast acrylic to allow viewing of the gel with a UV light source |
Unit Dimensions: 7cm(H) x 16.5cm(W) x 30.5cm(L) Gel Dimensions: 10cm x 15cm |
Shipping weight: 4.5 Lbs. |
Distance between the electrodes: 27cm |
Maximum Sample Capacity: 80 samples (4 combs, 20 samples each) |
Buffer Capacity: 500ml |
The maximum suggested applied voltage for the electrophoresis of DNA in agarose gels using the IB53000-MP1015 is 140 volts. In a 1% TBE gel, this translates into a run time of approx. 1 hour. Lower voltages can be used of course, and as a general rule a 70 volt run will take twice as long as a 140 volt run. Higher voltages can be used to decrease run time however, higher voltages can produce excessive heat and decrease sample resolution. |
Complete System Includes:
-
Buffer Tank
-
Patented Vented Lid
-
IB53020 UVT Casting Tray
-
IB53030 Casting Fixture
-
Two, 2.0mm x 16-tooth combs
-
Power Cords
-
Bubble Level
-
Buffer ports
- 4 year Warranty
Gel Size: 7cm(W) x 10cm(L)
Buffer volume: 250ml
Designed for Quick Screening and rapid, linear separation of nucleic acids. The QS710 requires
minimal set-up and provides excellent band resolution and consistent lane-to-lane mobility
for accurate results. A versatile system great for applications requiring quick screens such as
fragment analysis and recombinant screening.
Specifications: |
Construction: Buffer tank is constructed of 3/8" cast acrylic. |
Casting Tray bottom is constructed of UV Transmittance cast acrylic to |
Unit Dimensions: 6.4cm(H) x 11.4cm(W) x 22.2cm(L) |
Gel Dimensions: 7cm x 10cm |
Distance between the electrodes = 19.3cm |
Maximum sample capacity = 30 samples (2 combs / 15 samples ea) |
Buffer Capacity = 250ml |
Shipping weight = 3.0 lbs. |
The maximum suggested applied voltage for the electrophoresis of DNA in agarose gels using the QS710 is 100 volts. In a 1% TBE gel, this translates into a run time of approx. 1 hour. Lower voltages may be used, of course, and as a general rule, a 50 volt setting will take twice as long as a 100 volt setting. |
The suggested run parameters for the electrophoresis of RNA in agarose gels containing formaldehyde are 60 - 80 volts. |
Complete System Includes:
- Buffer Tank
- Patented Vented Lid
- IB51020 UVT Casting Tray
- IB51025 Casting Fixture
- Two, 1.5mm x 8-tooth combs
- Power Cords
- Bubble Level
- 4 year warranty
The IBI "Lab-Pal" has been designed with the teaching lab in mind. The IB50000 utilizes
two glass slides, measuring 2" x 3", for casting the agarose. The small glass slide
format is ideal for minimizing agarose use while still being an excellent teaching tool
for students just learning about the separation of DNA molecules.
Agarose slides can be cast days in advance and stored in buffer for later use. This helps maximize
class time
System Includes:
- Vented lid
- Dual casting fixture
- 4 glass casting slides
- (2) 1.5mm x 5-tooth combs
- Bubble level
- Power cords
- 4 year warranty
Large Tank Blotter with two cassettes, 20 x 20cm
- Designed to optimally transfer very large and difficult proteins.
- Reproducible transfer results thanks to the plate electrodes made
- of platinum-plated titanium (anode) and stainless steel (cathode).
- Efficient cooling system: Water circulation system with alumina
- ceramic wall located at the chamber base for effective heat
- removal.
- Safety lid: asymmetrical configuration of electrical contacts
- prevents mismatching of electrodes.
Double sided water cooled vertical system, 16cmW x 14cm
With its 16 cm wide x 14 cm tall format, the Reflection 1614 large-format, dual-gel vertical electrophoresis unit is great for separating complex protein samples. Run either one or two electrophoresis gels in this vertical gel box that provides both long run lengths and high separation capacity. With Galileo's unique casting base, users are able to both cast and run gels without ever having to unclamp the upper buffer chamber. This allows for safer and more convenient gel handling, especially for those who may be prone to ripping their gels between the two activities.
This vertical gel box includes a water cooling feature for electrophoresis protocols that require lower temperature. This water can be provided by the tap or other temperature controlled source and is easily connected by attaching standard tubing over the 3/8" barbed in/out ports on the device. Users may also facilitate cooling efficiency and uniformity using Galileo's optional alumina backer plates (see accessories below).
System Features
Each Reflection 85-1614 vertical system includes the following components:
- Heavy duty upper buffer chamber with cooling port connections
- Lower buffer chamber
- Interlock safety lid with attached leads
- Casting base
- Four-pack each of plain and notched glass plates
- One acrylic blocker plate (used when only one gel is being run)
- Eight 1.5mm thick side spacers
- Four combs of your choice
System Accessories
- Alumina cooling plate for use with cooling systems. This plate can be sandwiched between the gel and the inner buffer chamber to improve overall temperature uniformity.
- Casting base for quick, efficient and leak-proof gel casting.
Minigel System 7cm x 8 cm & (1) 6 and (1) 10 tooth comb
Perfectly sized for rapid analysis of small analytes like PCR and RE fragments. This unit features a RapidCast gasketed tray for quick in-unit gel casting.
System Description
Horizontal gel electrophoresis minigel system for 7cm x 8cm minigels. Includes gasketed UVT gel tray with fluorescent ruler, and (1) 6 and (1) 10 tooth comb, 1.5 mm thickness. Comb substitutions are available. Four year manufacturer warranty.
The standard 0708 mini gel system includes a RapidCast™ gasketed gel tray for convenient gel casting right in the buffer chamber.
System features
The 0708 complete system includes these features:
- Heavy duty lower buffer chamber
- Interlock safety lid with attached leads
- Gasketed (cast in place) 7cm wide x 8cm long UV-transparent gel tray with built-in fluorescent ruler and 2 comb slots.
- One 1.5mm x 6 tooth comb
- One 1.5mm x 10 tooth comb
Horizontal Electrophoresis System, 20 cm x 25 cm
Horizontal Large Gel Electrophoresis System for 20cmW x 25cm gel. Includes 20cm x 25cm UVT Gel Tray w/ end gates & (1) 16, (1) 24 and (1) 36 Tooth, 1.5 mm thickness. Includes four year warranty.The 81-2025 is a medium capacity system. With a maximum run length of 25cm, the unit can provide high resolution of complex analytes. Or, fitted with maximum capacity combs in all of the tray's 6 comb slots, the unit can handle up to 168 samples. The 2025 features the Galileo ExpressCast gel casting system for quick, tape-free gel casting and includes a built-in bubble level and leveling screws for convenient level adjustment. You may choose from a wide variety of comb options to customize your order.
- Heavy duty lower buffer chamber
- Interlock safety lid with attached leads
- End gated 20cm wide x 25cm long ExpressCast™ UV-transparent gel tray with built-in fluorescent ruler and 6 comb slots.
- One 1.5mm x 16 tooth combs, one 1.5mm x 24 tooth combs, one 1.5mm x 36 tooth combs
The system is simple and self contained. A trapping system captures hydrogen bubbles created by electrolysis of the buffer at the cathode (-) end of the unit. As these bubbels move up the canted recirculation tube, they carry buffer along with them and provide a gentle and reliable recirculation system. This system is self regulating and no additional tubing or pumps are required.