S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
Actions
EasyScript cDNA Synthesis Kit
Order# |
Description |
Quantity |
Rxn |
G233 |
EasyScript cDNA Synthesis Kit |
5000U (25uL) |
25 rxns |
G234 |
EasyScript cDNA Synthesis Kit |
20,000U (100uL) |
100 rxns |
Application:
- First strand cDNA synthesis for PCR
- Construction of cDNA libraries
- Generation of probes for hybridization
EasyScript cDNA Synthesis Kit is a complete system for the efficient synthesis of first strand cDNA from RNA templates. The recombinant RNasin Ribonuclease Inhibitor, supplied with the kit effectively protects RNA template from degradation.
The kit is also supplied with both oligo(dT) and random primers. The oligo(dT) anneals selectively on the poly(A) tail of mRNA. Random primers do not require the presence of poly(A). Therefore, they can be used for transcription of the 5'-end regions of mRNA. Gene-specific primers may also be used with the kit. The first strand of cDNA can be directly used as a template in PCR.
EasyScript Reverse Transcriptase (RTase) within the kit is a genetically modified form of Moloney Murine Leukemia Virus Reverse Transcriptase (M-MLV). Both the EasyScript and EasyScript Plus are RNase H deficient (negative). The enzyme is purified from bacteria host as a single holoenzyme of 71 kDa with the capacity of first-strand cDNA synthesis of template up to 9kb and can be used for routine cDNA synthesis.
Kit Components:
Components |
EasyScript cDNA Synthesis Kit |
|
|
G233 |
G234 |
EasyScriptRTase (200U/µl) |
5,000U |
20,000U |
Oligo(dT) (10µM) |
40 µl |
160 µl |
Random Primers (10µM) |
40 µl |
160 µl |
5x RT buffer |
150 µl |
600 µl |
RNasin (40U/µl) |
15 µl |
60 µl |
dNTP (10mM) |
40 µl |
160 µl |
RNase-free H2O |
1 ml |
2x1 ml |
Size |
25 rxns |
100 rxns |
Storage Buffer:
50mM Tris-HCl (pH 8.3), 100 mM NaCl, 0.1 mM EDTA, 5 mM DTT, 0.1% (v/v) Triton X-100, and 50% (v/v) glycerol.
Storage:
Store at -20°C in a frost-free freezer. Multiple freezing and thawing of RNA should be avoided. Keep RNA on ice all the time. It is recommended that the first strand cDNA synthesis is carried out under conditions where RNase contamination has been eliminated.
General Protocol:
RT-PCR reactions should be assembled in a RNA-free environment. The use of "clean", automatic pipettes designated for PCR and aerosol resistant barrier tips are recommended.
1. Thaw template RNA and all reagents on ice. Mix each solution by vortexing, and centrifuge briefly to collect residual liquid from the sides of the tubes.
2. Prepare the following reaction mixture in a PCR tube on ice:
|
Volume |
Concentration (final 20µl) |
Total RNA, or poly(A)+RNA |
Variable |
0.5-5µg per reaction |
|
|
50ng-0.5µg per reaction |
Oligo(dT) (10µM) |
1µl |
0.5µM |
or Random Primer (10µM) |
1µl |
0.5µM |
or Sequence-specific Primer |
Variable |
10-15pM |
dNTP (10mM) |
1µl |
500µM |
5X RT Buffer |
4µl |
1X |
RNasin (40U/µl) |
0.5µl |
20U per reaction |
EasyScript RTase (200U/µl) |
1µl |
200U per reaction |
RNase-free H2O |
Variable |
- |
Final volume |
20µl |
- |
3. Incubate at 25°C for 10 minutes if random primer is used. Omit this step if Oligo(dT) primer or sequence specific primer are used.
4. Incubate the mixture at 42°C for 60 minutes.
5. Stop the reaction by heating at 85°C for 5 minutes.
6. Chill on ice. The newly synthesized first-strand cDNA now can be used directly for PCR amplification.
Notes:
1. Isolation of poly(A)+ RNA from total RNA is not mandatory; however, doing so may improve the yield and purity of the final product.
2. RNA sample must be free of contaminating genomic DNA.
3. Unlike the oligo(dT) priming, which usually requires no optimization, the ratio of a random primer to RNA is critical in terms of the average length of cDNA synthesized in the reaction. Increasing the ratio of random primer/RNA will result in higher yield of shorter (~500 bp) cDNA, whereas decreasing this ratio will produce longer products.
4. The synthesized cDNA should be stored at -20°C.
EasyScript Reverse Transcriptase
Order# |
Description |
Quantity |
Rxn |
G231 |
EasyScript Reverse Transcriptase |
5000U (25uL) |
25 rxns |
G232 |
EasyScript Reverse Transcriptase |
20,000U (100uL) |
100 rxns |
Application:
- Synthesis cDNA froma single-stranded RNA or DNA primer extension
- Sequencing dsDNA
- cDNA library
- Template production for use in PCR
- 3'-end labeling of duplex DNA via end-filling reactions
EasyScript Reverse Transcriptase is a genetically modified form of Moloney Murine Leukemia Virus Reverse Transcriptase (M-MLV). Both the EasyScript and EasyScript Plus are RNase H deficient (negative). The enzyme is purified from bacteria h o s t as a single holoenzyme of 71 kDa with the capacity of first-strand cDNA synthesis of template up to 9kb and can be used for routine cDNA synthesis.
Kit Components:
Components |
EasyScript Reverse Transcriptase |
|
|
G231 |
G232 |
EasyScript RTase (200U/µl) |
5,000U |
20,000U |
5x RT buffer |
150 µl |
600 µl |
Size |
25 rxns |
100 rxns |
Storage Buffer:
50mM Tris-HCl (pH 8.3), 100 mM NaCl, 0.1 mM EDTA, 5 mM DTT, 0.1% (v/v) Triton X-100, and 50% (v/v) glycerol.
Storage:
Store at -20°C in a frost-free freezer. Multiple freezing and thawing of RNA should be avoided. Keep RNA on ice all the time. It is recommended that the first strand cDNA synthesis is carried out under conditions where RNase contamination has been eliminated.
General Protocol:
RT-PCR reactions should be assembled in a RNA-free environment. The use of "clean", automatic pipettes designated for PCR and aerosol resistant barrier tips are recommended.
1. Thaw template RNA and all reagents on ice. Mix each solution by vortexing, and centrifuge briefly to collect residual liquid from the sides of the tubes.
2. Prepare the following reaction mixture in a PCR tube on ice:
|
Volume |
Concentration (final 20µl) |
Total RNA, or poly(A)+RNA |
Variable |
0.5-5µg per reaction |
|
|
50ng-0.5µg per reaction |
Oligo(dT) (10µM) |
1µl |
0.5µM |
or Random Primer (10µM) |
1µl |
0.5µM |
or Sequence-specific Primer |
Variable |
10-15pM |
dNTP (10mM) |
1µl |
500µM |
5X RT Buffer |
4µl |
1X |
RNasin (40U/µl) |
0.5µl |
20U per reaction |
EasyScript RTase (200U/µl) |
1µl |
200U per reaction |
RNase-free H2O |
Variable |
- |
Final volume |
20µl |
- |
3. Incubate at 25°C for 10 minutes if random primer is used. Omit this step if Oligo(dT) primer or sequence specific primer are used.
4. Incubate the mixture at 42°C for 60 minutes.
5. Stop the reaction by heating at 85°C for 5 minutes.
6. Chill on ice. The newly synthesized first-strand cDNA now can be used directly for PCR amplification.
Notes:
1. Isolation of poly(A)+ RNA from total RNA is not mandatory; however, doing so may improve the yield and purity of the final product.
2. RNA sample must be free of contaminating genomic DNA.
3. Unlike the oligo(dT) priming, which usually requires no optimization, the ratio of a randomprimer to RNA is critical in terms of the average length of cDNA synthesized in the reaction. Increasing the ratio of random primer/RNA will result in higher yield of shorter (~500 bp) cDNA, whereas decreasing this ratio will produce longer products.
4. The synthesized cDNA should be stored at -20°C.
ENDURO VE20 Vertical Gel Electrophoresis System
Enduro VE20 Vertical Electrophoresis System (20 x 20 cm), includes glass plates, 2 x 24 well combs, cooling coil and casting base
- Large format vertical gel system
- Electroblotting and gel electrophoresis in same universal gel tank
- Quick assembly system for ease of use
- Complete system allows casting of gels and running of gels at same time increasing efficiency
The ENDURO VE20 is Labnet's new large format vertical gel electrophoresis system. It distinguishes itself in its flexibility of applications and ease of gel casting and set-up requiring only 4 screws to secure 4 gels. The same gel tank can house a large format electroblotting assembly sold separately. This system is ideal for first- and second dimension SDS-PAGE, native, preparative, gradient and high-resolution nucleic acid electrophoresis.
Innovative screw-clamp technology consists of only four screws to secure up to four 20 x 20cm gels. This vertical screw clamp technology distributes pressure evenly along the height of gel rather than in the center to eliminate plate bowing and gel compression, while maintaining a leak-proof seal during casting.
NO TANK TOP ASSEMBLY
A built-in inner buffer chamber within the PAGE insert allows set up to be completed without inclusion of an upper buffer chamber.
CASTING ADVANTAGES
- Dual purpose PAGE insert eliminates time consuming transfer of glass plates between separate casting and gel running components.
- Glass plates with bonded spacers assure clean well formation, correct alignment for leak-free casting and eliminates manually aligning spacers.
- Casting stand design ensures leak-free casting even if glass plates are misaligned.
Specifications:
Plate Dimensions (w x h x t) |
20 x 20 x 0.4 cm |
Standard Spacer (w x h) |
2 x 20 cm |
IPG Spacer (w x h) |
0.6 x 20 cm |
Unit (w x d x h) |
30 x 18 x 27 cm |
Unit weight |
5.5 lbs |
Number of gels |
4 |
Total volume inner buffer chamber |
640 mL |
Total buffer volume for 2 gels |
5.3 L |
Total buffer volume for 4 gels |
4.8 L |
Standard run time for SDS-PAGE without coolling |
4-5 hr |
Standard run time for SDS-PAGE with coolling |
3-4 hr |
Order# |
Description |
E2020 |
Enduro VE20 Vertical Electrophoresis System (20 x 20 cm), includes glass plates, 2 x 24 well combs, cooling coil and casting base |
E2020-CU |
Enduro VE20 Dual Casting System, includes 20 x 20 cm Dual, 2 sets of glass plates, 1 mm think bonded spacers, 2 x 24 sample, 1 mm thick combs, cooling coil, dummy plate; also includes caster and external casting |
E2020-IEF |
Enduro VE20 IEF Conversion Kit for 18 cm IPG strips and Tube gels |
E2020-TB |
Enduro VE20 Blotting System, 20 x 20 cm System Including tank and lid, 4 cassettes, 18 fibre pads, cooling coil |
ENDURO™ Semi Dry Blotter
- Western, Southern, and Northern Blots
- Rapid transfer times
- Uniform head dispersion
- Variable gel thickness
- Minimal buffer volume
The ENDURO™ Semi-Dry Blotter provides great flexibility in a lab since it can be used for all types of blotting: Western, Southern, and Northern. Blotting with the ENDURO™ Semi Dry Blotter typically can be done in 15 to 30 minutes making it a fast and easy way to do all your blotting applications. Set up procedures are easy and economical with little buffer needed. The screw down lid adjusts to varying gel thicknesses and sizes while the platinum coated electrodes provide uniform pressure ensuring even transfers. To provide your lab with total blotting solutions use with our ENDURO™ 250V, 3000mA high current power supply.
Specifications
Dimensions |
32.5
x 25 x 5.5 cm | 12.8 x 9.8 x 2.2 in |
Buffer Volume |
20 mL |
Sample Capacity |
4
Blots: 8 x 8.5 cm | 2 Blots: 16 x 8.5 cm | 1 Blot: 16 x 17.5 cm |
Semi-Dry Blotting Systems, 10cm x 10cm
Choose Galileo Insight™ semi-dry sytems for rapid and efficient molecular transfer.
MAIN FEATURES
ColonyDoc-It - Fast, Accurate Colony Counting - Innovative Colony Counter Design
Capture the Colonies
-
DigiCam 130 digital color camera with 17.9 megapixel resolution
-
Select from several light sources for illuminating a wide range of stained media
-
Slide the filter selector to one of two positions
-
A wide range of emission filters are available
-
The plate alcove accommodates pour, spread and spiral plates and filters with sizes from 33mm to 150mm
-
Capture colony sizes as small as 0.08mm
-
Generate fast automatic and accurate colony counting with detailed statistics
-
Define parameters including eight color differentiation, split or merge, filter by group or size
-
Attach the door (not shown) to create a darkroom environment when imaging colonies with GFP fluorescence
Select from Several Light Sources
When colony samples require different light sources, the ColonyDoc-It enables the easy selection of bright LED lighting. The white light and fluorescent sources visualize a wide array of bacterial, yeast and mold colonies with samples found in air, water, food and cosmetics. The blue light is used for colonies stained with green fluorescent protein (GFP). Doors (detachable) create a darkroom environment when imaging colonies with GFP. Select from:
-
Darkfield
-
Epi and transillumination white light
-
Epi blue light
High Resolution Camera
The integrated 17.9 megapixel digital color camera lets you quickly capture and see all of the details in your colony sample. The high resolution capabilities allow capture of images down to 0.08mm. No need to adjust camera buttons, since the camera is easily controlled by the software.
Colony Counter Software
The ColonyDoc-It software loads on your computer* for camera control, image capture and analysis. The software enables automatic and manual colony counting capabilities. Users can define specific counting parameters including color differentiation, splitting or merging colonies, identifying filters by group or size. Users can create templates for specific camera settings and analysis functions, allowing the same settings to be selected each time an experiment is run.
Generate Reports
The accurate count and statistical reporting functions enable researchers to immediately identify and determine experimental parameters that are critical for colony growth and inhibition. The software generates statistics and displays the most critical information about the colony area, perimeter, average diameter and circularity. The data is easily exported into Excel.
* Computer ordered separately.PR1MA™ Reverse Transcriptase, RNase H -
PR1MA™ reverse transcriptase (RT) is an RNA-dependent DNA polymerase ideal for use in RT-PCR and first-strand synthesis of complementary DNA (cDNA) for generation of cDNA libraries from single-stranded RNA, DNA, or RNA:DNA hybrids.
- Decreased RNase H activity enables longer cDNA synthesis (>5 kb).
- Lacks 3’ to 5’ exonuclease activity
- Optimal temperature at 42°C
- Temperature range: 40 to 50°C
- Heat inactivation: 70°C for 20 minutes
- Storage temperature: -20°C
- 10X reaction buffer included
Buffer composition
- 50% glycerol
- 50 mM Tris-HCl
- 50 mM KCl
- 1 mM DTT
- 0.1 mM EDTA
- pH = 7.5
*These products are intended for research use only, not for therapeutic or diagnostic purposes in humans or animals. The safety and efficacy of these products in diagnostic or other clinical uses has not been established.
Our Owl EC-1000XL Compact Power Supply is simple-to-use, multi-purpose and lightweight. The supply features a power-off memory to retain settings after shut-down as well as a stackable design to save benchtop space. It also has a soft-touch key pad and 4 jacks. 3 year warranty
Max. Voltage: 1000 V
Max. Current: 500 mA
Max. Power: 250 W
Great for DNA / RNA, Protein and Blotting electrophoresis.
New electronic ballast and cutting-edge construction offers:
- Increased ultraviolet output and intensity
- No light flicker
- Wider intensity range with variable selection (select models)
- Fast lamp start up
- Universal power supply
- Reduced electrical consumption
- Longer tube life
- Lighter weight
- Improved gel visualization and gel documentation
- 2 year warranty
Models available include:
- 365nm longwave UV and white light
- 302nm midrange UV and white light or
- Combination 2UV 365nm longwave, 302nm midrange and white light
- Easily switch among the light sources with the rocker switch on the front of the unit
- Each UV and white light surface area measures 20 x 20cm
- Hinged, clear UV blocking cover, included with each transilluminator, is height adjustable for access to the filter surface
- All transilluminators carry a two-year warranty
Specifications
Light Source: | 365nm or 302nm UV White Light |
---|---|
Watts: | 8 watts |
Dimensions: |
13.25D x 19.13W x 5H in. (279 x 356 x 143mm) Height includes UV blocking cover |
Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.
Part Numbers | |||||
---|---|---|---|---|---|
110 - 115V | 230V | Model | Intensity Style | Wavelength | Filter Size |
95-0415-01 | 95-0415-02 | TLW-20 | Single | 365nm/White | 20x20cm two sides |
95-0415-04 | 95-0415-05 | TMW-20 | Single | 302nm/White | 20x20cm two sides |
95-0418-01 | 95-0418-02 | LMW-20 | Single | 365/302nm/White | 20x20cm two sides |
Replacement Tubes |
Replacement Tube | 34-0056-01 | 8 watt, White | |||
---|---|---|---|---|---|
Replacement Tube | 34-0006-01 | 8 watt, 365nm | |||
Replacement Tube | 34-0042-01 | 8 watt, 302nm |
UltraBright LED Transilluminator
- Safer to use that standard UV transillumiators
- NO UV hazard to skin and eyes.
- NO DNA damage inherent to UV - No worries when cutting out bands for elution.
- Easy for use and gel cutting
- NO need to wear amber glasses.
- Adjustable intensity: from 100% down to 50%.
- The THINNEST blue LED illuminator in the world.
- Strong blue LED for excitation.
- Uniform: <5% coefficient of variance (CV) across the full filter area.
- Compact and Light: 30 mm in height
- Wide applications other than DNA/RNA gel visualization, such as fluorescent proteins.
- Sensitive for a wide range of fluorphores: DNA SafeStain, GelGreen, GelRed, EthBr, SYBR® Safe, SYBR Gold, SYBR Green I® & II, SYPRO® Rudy, SYPRO® Orange, Coomassie Fluor Orange stains, and Lumitein Protein Gel Stain.
The UltraBright LED Transilluminator is ultra-bright and provides safer blue LEDs and easy gel cutting amber filter. Higher sensitivity leads to compatibility with most stains. Full size viewing surface is 160mm x 200 mm.
Accuris MyVolt™ Mini Power Supply
- Compact and simple
- Choose constant 100 V or 200 V output
- Two pairs of output terminals
The Accuris MyVolt Mini is a compact electrophoresis power supply ideal for basic, constant voltage applications. Users can select constant 100 V or 200 V output, and the current can reach a maximum of 200 mA.
Two sets of output jacks are available to connect up to 2 gel rigs and these small power supplies can securely be stacked for use with additional gel rigs.
Specifications
Output Voltage | 100V/200V constant |
Current Output | Max. 200mA |
Max Wattage | 40W |
Output Terminals | 2 pairs |
Weight | 0.9 lbs / 0.4 kg |
Dimensions | 6.25 x 4.5 x 2.3 in. 16 x 11.5 x 5.7 cm |
Electrical | 100 - 240V, 50-60Hz |
Wide Format Gel System 23.5 cm x 14 cm
Horizontal Wide Format Gel System for 23.5cm x 14cm gels. Includes UVT gel tray four comb slots and end gates & (4) 50 Tooth combs, 1.5 mm thickness.
System Description
A high-capacity system in a mini-gel size, the Galileo 2314 unit enables rapid separation of large numbers of samples.
The 2314 wide format system accomodates up to 200 samples per run, for quick separation and high thru-put. Because of the wide format of the Galileo 2314 unit, the 23cm wide by 14cm long tray is non-gasketed. Gel casting can be accomplished by taping, or we recommend the G-80-WADJ-CST multi-casting unit for even quicker and more convenient gel casting. The gel tray is UV transmissible, includes an imprinted fluorescent ruler, and has 4 comb slots. Choose from a wide variety of comb options, all with micro-titer spacing for easy loading with multi-channel pipets.
System Features
The Galileo 2314 complete system includes these features:
- Heavy duty lower buffer chamber
- Interlock safety lid with attached leads
- Non-gasketed 23cm wide x 14cm long UV-transparent gel tray with built-in fluorescent ruler and 4 comb slots.
- Four 1.5mm x 50 tooth combs
- Opaque well visualization plate.