S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
- Lyophilized components to ship without cold chain
- Highly specific detection profile and high priming efficiency
- Rapid detection of COVID-19 and does not detect other related coronavirus strains
Design of our COVID-19 was an intricate process using a dedicated team of expert bioinformaticians. Finding the right sequence is critical for not only assay specificity, but also sensitivity which can be inhibited by primer-dimer formation. These ultimately reduce the assay's ability to detect SARS-CoV-2 accurately. However, the right design will mitigate these risks and ensure a specific, sensitive and accurate test, as we have done.
Our surveillance program is in place to track the mutation of the virus. Our expert bioinformaticians analyze daily published virus sequences to ensure our test maintains a 100% detection profile. Each new mutation presents a risk to any COVID-19 kit detection and false negatives without surveillance programs in place. As of the 17th July 2020 our COVID-19 test has a 100% detection profile with the 42,655 full length, good quality SARS-CoV-2 sequences published on the GISAID-EpiCoV database.
Ensuring your COVID-19 test is stable during transit and storage is vital to prevent reagent degradation. Within our COVID-19 genesig® Real Time PCR assay we provide oasig components that are provided freeze dried which stabilizes the active components. This enables the reagents to be shipped at ambient temperature. This simplifies the logistics of shipping and is cost effective. If you're in a sophisticated laboratory or a mobile field hospital we can supply complete qPCR packages to your door quickly and cheaply via standard shipping methods without the need for dry ice or a cold chain of any sort.
The COVID-19 genesig® Real Time PCR assay was granted Emergency Use Authorization Only by the United States Food and Drug Administration (FDA).
- Increased ultraviolet output and intensity
- No light flicker
- Wider intensity range with variable selection (select models)
- Fast lamp start up
- Universal power supply
- Reduced electrical consumption
- Longer tube life
- Lighter weight
- Improved gel visualization and gel documentation
- UVP's patented 3UV Benchtop Transilluminator provides the selection of 365nm, 302nm and 254nm in one compact unit
- 2UV models offer 302nm and 365nm UV in one model
- Easily view gels under 365nm longwave UV for extended periods of time avoiding photonicking damage. Researchers can use the 302nm midrange to increase the fluorescence for photodocumentation. Shortwave 254nm UV is used to irradiate samples
- All Benchtop Transilluminator models are compact, lightweight units
- These 8-watt models provide a low cost alternative to the High Performance UV Transilluminators
- A variety of filter area work surface sizes are available
- Hinged, clear UV blocking cover, included with each transilluminator, is adjustable for access to the filter surface
- 2 year warranty
WARNING: Transilluminators are powerful sources of ultraviolet radiation which can cause serious damage to unprotected eyes and skin. Read the ultraviolet Caution Information before operating any transilluminators.
* Except M-10 which has standard ballast, 115V unit.
Intensity :
- Select models offer single intensity other models include variable intensity. Refer to the part numbers tab for information.
- Variable intensity settings-High/Medium/Low
- High setting allows for UV excitation of fluorophores on gels for routine photography. Medium is excellent for viewing and quick single-band excision. Low setting allows for positioning and preparation of gels, excising multiple bands, and focusing for photography.
UV Source: Refer to the Part Numbers tab for specific wavelengths for each model
Watts: 8 watts, except M-10 which is 6 watts
Dimensions:
- 3UV Models: 11D x 14W x 5.4H in. (279 x 356 x 137mm)
- 2UV Models: 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- Single UV/Variable Intensity Models (Except M-10): 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- M-10: 7.25D x 10.25W x 4.5H in. (184 x 260 x 114mm)
- Height includes UV blocking cover (all models)
Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.
Options- Gel Tools
- Converter Plates
- BioImaging Systems
95-0457-01 (115V) | M-26E | Single | 302nm | 8 watt | 21x26cm |
Single UV / Variable Intensity | |||||
95-0456-01 | M-15V | Variable | 302nm | 8 watt | 15x15cm |
95-0452-01 | M-20V | Variable | 302nm | 8 watt | 20x20cm |
95-0458-01 | M-26V | Variable | 302nm | 8 watt | 21x26cm |
95-0413-01 | M-26XV | Variable | 302 | 8 watt | 25x26cm |
2UV / Single Intensity | |||||
95-0449-01 | LM-20 | Single | 302/365nm | 8 watt | 20x20cm |
95-0459-01 | LM-26 | Single | 302/365nm | 8 watt | 21x26cm |
3UV / Single Intensity | |||||
95-0417-01 | LMS-20 | Single | 254/302/365nm | 8 watt | 20x20cm |
95-0414-01 | LMS-26 | Single | 254/302/365nm | 8 watt | 21x26cm |
- Increased ultraviolet output and intensity
- No light flicker
- Wider intensity range with variable selection (select models)
- Fast lamp start up
- Universal power supply
- Reduced electrical consumption
- Longer tube life
- Lighter weight
- Improved gel visualization and gel documentation
- UVP's patented 3UV Benchtop Transilluminator provides the selection of 365nm, 302nm and 254nm in one compact unit
- 2UV models offer 302nm and 365nm UV in one model
- Easily view gels under 365nm longwave UV for extended periods of time avoiding photonicking damage. Researchers can use the 302nm midrange to increase the fluorescence for photodocumentation. Shortwave 254nm UV is used to irradiate samples
- All Benchtop Transilluminator models are compact, lightweight units
- These 8-watt models provide a low cost alternative to the High Performance UV Transilluminators
- A variety of filter area work surface sizes are available
- Hinged, clear UV blocking cover, included with each transilluminator, is adjustable for access to the filter surface
- 2 year warranty
WARNING: Transilluminators are powerful sources of ultraviolet radiation which can cause serious damage to unprotected eyes and skin. Read the ultraviolet Caution Information before operating any transilluminators.
* Except M-10 which has standard ballast, 115V unit.
Intensity :
- Select models offer single intensity other models include variable intensity. Refer to the part numbers tab for information.
- Variable intensity settings-High/Medium/Low
- High setting allows for UV excitation of fluorophores on gels for routine photography. Medium is excellent for viewing and quick single-band excision. Low setting allows for positioning and preparation of gels, excising multiple bands, and focusing for photography.
UV Source: Refer to the Part Numbers tab for specific wavelengths for each model
Watts: 8 watts, except M-10 which is 6 watts
Dimensions:
- 3UV Models: 11D x 14W x 5.4H in. (279 x 356 x 137mm)
- 2UV Models: 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- Single UV/Variable Intensity Models (Except M-10): 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- M-10: 7.25D x 10.25W x 4.5H in. (184 x 260 x 114mm)
- Height includes UV blocking cover (all models)
Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.
Options- Gel Tools
- Converter Plates
- BioImaging Systems
95-0457-01 (115V) | M-26E | Single | 302nm | 8 watt | 21x26cm |
Single UV / Variable Intensity | |||||
95-0456-01 | M-15V | Variable | 302nm | 8 watt | 15x15cm |
95-0452-01 | M-20V | Variable | 302nm | 8 watt | 20x20cm |
95-0458-01 | M-26V | Variable | 302nm | 8 watt | 21x26cm |
95-0413-01 | M-26XV | Variable | 302 | 8 watt | 25x26cm |
2UV / Single Intensity | |||||
95-0449-01 | LM-20 | Single | 302/365nm | 8 watt | 20x20cm |
95-0459-01 | LM-26 | Single | 302/365nm | 8 watt | 21x26cm |
3UV / Single Intensity | |||||
95-0417-01 | LMS-20 | Single | 254/302/365nm | 8 watt | 20x20cm |
95-0414-01 | LMS-26 | Single | 254/302/365nm | 8 watt | 21x26cm |
New electronic ballast and cutting-edge construction offers:
- Increased ultraviolet output and intensity
- No light flicker
- Wider intensity range with variable selection (select models)
- Fast lamp start up
- Universal power supply
- Reduced electrical consumption
- Longer tube life
- Lighter weight
- Improved gel visualization and gel documentation
- High performance 25-watt UV tubes for high fluorescence and sensitivity on stained gels
- Stainless steel cover frame provide an easy clean surface and reduces cross contamination of samples
- Uniform, brilliant back-lit fluorescence illumination is enhanced with UVP's unique background uniformity screen and UVG long-life filter
- Uniformity screen is available on units with midrange or longwave UV
- The transilluminator's powerful cooling fan maintains a low filter surface temperature to prevent sample damage and maintains a constant UV intensity
- The removable and adjustable protective UV blocking cover is included with each transilluminator
- Transilluminators carry a two-year warranty
- 2 year warranty
WARNING: Transilluminators are powerful sources of ultraviolet radiation which can cause serious damage to unprotected eyes and skin. Read the ultraviolet Caution Information before operating any transilluminators.
Intensity:- Select models offer single intensity other models include variable intensity. Refer to the part numbers tab for information.
- Variable intensity settings - High/Medium/Low
- High setting allows for UV excitation of fluorophores on gels for routine photography. Medium is excellent for viewing and quick single-band excision. Low setting allows for positioning and preparation of gels, excising multiple bands, and focusing for photography.
UV Source: 254nm, 302nm or 365nm
Watts: 25 watts
Dimensions: All Benchtop models : 13.25D x 19.13W x 5.63H in.
- Height includes UV blocking cover
- Weight: 21 lb. (9.6 kg)
Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.
Part Numbers | |||||
---|---|---|---|---|---|
100-115V | 230V | Model | Intensity Style | Wavelength | Filter Size |
Variable UV Intensity | |||||
95-0420-01 | 95-0420-02 | TFL-40V | Variable | 365nm | 20x40cm |
95-0423-01 | 95-0423-02 | TFM-20V | Variable | 302nm | 20x20cm |
95-0422-01 | 95-0422-02 | TFM-26V | Variable | 302nm | 21x26cm |
95-0424-01 | 95-0424-02 | TFM-30V | Variable | 302nm | 25x30cm |
95-0421-01 | 95-0421-02 | TFM-40V | Variable | 302nm | 20x40cm |
95-0427-01 | 95-0427-02 | TFS-20V | Variable | 254nm | 20x20cm |
95-0428-01 | 95-0428-02 | TFS-26V | Variable | 254nm | 21x26cm |
95-0429-01 | 95-0429-02 | TFS-30V | Variable | 254nm | 25x30cm |
95-0430-01 | 95-0430-02 | TFS-40V | Variable | 254nm | 20x40cm |
2UV | |||||
95-0431-01 | 95-0431-02 | TFML-20 | Single | 302/365nm | 20x20cm |
95-0432-01 | 95-0431-02 | TFML-30 | Single | 302/365nm | 25x30cm |
95-0425-01 | 95-0425-02 | TFML-26 | Single | 302/365nm | 21x26cm |
95-0426-01 | 95-0426-02 | TFML-40 | Single | 302/365nm | 20x40cm |
Replacement Tubes |
Replacement Tube | 34-0073-01 | 25-watt, 254nm | |||
---|---|---|---|---|---|
Replacement Tube | 34-0072-01 | 25-watt, 302nm | |||
Replacement Tube | 34-0060-01 | 25-watt, 365nm |
- Small footprint for benchtop use
- Preset and manual controls for ultraviolet or time exposures. Preset exposure delivers 120,000 microjoules or five minutes of exposure
- Microprocessor measures and control UV output, ensuring maximum energy efficiency
- Large LED display and touch panel which displays time or energy settings
- Window on the door allows viewing of the process yet blocks out the UV radiation
- Select from models with 302nm midrange UV, 365nm longwave UV or 254nm shortwave UV Interior: 12 deep x 10 wide x 5 high inches (305 x 254 x 127mm)
- Overhead UV supplies uniform UV
- Shortwave UV model is available with choice of door (CL-1000) or drawer (CX-2000) styles
- Built-in UV sensor is calibrated at the UVP factory to ensure accuracy and reliability
- Crosslinking for attaching nucleic acids to a membrane takes seconds as compared to oven baking
CL-1000 Dimensions: Exterior: 13.7 deep x 15.6 wide x 8.75 high inches (248 x 396 x 222mm)
CX-2000 Dimensions:
Exterior: 17.5"W x 15"D x 9.75"H (445 x 381 x 248mm)
Interior: 11.4"W x 11.3"D x 3.6"H (290 x 287 x 91mm)
Depth of sample tray 11.25 Width of sample tray 11.5
Sample surface to lamp approximately 3.5 in. (89mm)
1 year warranty
|
Cutting-edge construction of UVP transilluminators includes an electronic ballast for increased stability and reduced power consumption. They also have a compact size to fit conveniently in small laboratory spaces. Benchtop UV transilluminators feature a fast lamp start-up with no light flicker. The FirstLight UV Illuminators offer high sensitivity and <5% coefficient of variance (CV) across the full filter area for consistency across the entire illuminated surface.
The FirstLight® UV Illuminator represents a unique highly uniform excitation source for quantitative fluorescent imaging in a wide range of genomic and proteomic applications:
- Electrophoretic separation and quantiation of 1D and 2D protein separations
- Solid phase immunoassay
- DNA quantitation
- RNA quantitation
Specifications: |
|
UV Source: |
UV Grid |
Wavelength: |
302 nm |
Intensity: |
Single |
UV Blocking Cover: |
Included |
Dimensions (WxDxH): |
14x11x5.63 inches |
Warranty: |
2 year |
- Lamps are lightweight.
- Models available include shortwave, longwave UV or a combination shortwave/longwave version
- Combination version comes with a snap-on wavelength selector for switching between wavelengths
- Use these lamps with the J-129 Lamp Stand (pictured) or the C-10 Cabinet
- 1 year warranty
Handheld Lamp Dimensions:
14.9"L x 3.2"W x 2.5"H
Lamp Stand Dimensions: 9.5"H x 13"L
Shortwave XX Series Lamps use ultraviolet radiation as a reliable and effective tool for sterilization and sanitation applications in hospitals, laboratories, pharmaceutical companies, and clinics. Work surfaces and equipment can become contaminated with bacteria which may be passed through the air or by hand infecting research projects and workers. In addition to bacteria, yeast, mold spores, germs, and viruses may also be present. Shortwave XX Series UV Lamps can kill up to 99% of these organisms. Decontaminate work surfaces with UV prior to PCR to reduce air-borne contamination during DNA sequencing. UV sterilization is particularly useful for temperature sensitive applications due to low operating lamp temperatures.
Shortwave Lamps can be used in an upward facing position for purifying the air or in a downward position for sanitizing work surfaces. Hanging the lamp (brackets provided) reduces the space required on laboratory benchtops. Longwave UV Bulbs (365nm) also available for all models. 1 year warranty
Dimensions
XX-15: 19.75"L x 6"W x 4.25"H
XX-20: 24"L x 6"W x 4.25"H
XX-40: 49.6"L x 6"W x 4.25"H
Exposure Stand: 20"L x 6"W x 13"H
Large Tank Blotter with two cassettes, 20 x 20cm
- Designed to optimally transfer very large and difficult proteins.
- Reproducible transfer results thanks to the plate electrodes made
- of platinum-plated titanium (anode) and stainless steel (cathode).
- Efficient cooling system: Water circulation system with alumina
- ceramic wall located at the chamber base for effective heat
- removal.
- Safety lid: asymmetrical configuration of electrical contacts
- prevents mismatching of electrodes.
Double sided water cooled vertical system, 16cmW x 14cm
With its 16 cm wide x 14 cm tall format, the Reflection 1614 large-format, dual-gel vertical electrophoresis unit is great for separating complex protein samples. Run either one or two electrophoresis gels in this vertical gel box that provides both long run lengths and high separation capacity. With Galileo's unique casting base, users are able to both cast and run gels without ever having to unclamp the upper buffer chamber. This allows for safer and more convenient gel handling, especially for those who may be prone to ripping their gels between the two activities.
This vertical gel box includes a water cooling feature for electrophoresis protocols that require lower temperature. This water can be provided by the tap or other temperature controlled source and is easily connected by attaching standard tubing over the 3/8" barbed in/out ports on the device. Users may also facilitate cooling efficiency and uniformity using Galileo's optional alumina backer plates (see accessories below).
System Features
Each Reflection 85-1614 vertical system includes the following components:
- Heavy duty upper buffer chamber with cooling port connections
- Lower buffer chamber
- Interlock safety lid with attached leads
- Casting base
- Four-pack each of plain and notched glass plates
- One acrylic blocker plate (used when only one gel is being run)
- Eight 1.5mm thick side spacers
- Four combs of your choice
System Accessories
- Alumina cooling plate for use with cooling systems. This plate can be sandwiched between the gel and the inner buffer chamber to improve overall temperature uniformity.
- Casting base for quick, efficient and leak-proof gel casting.
UltraSlim® LED Illuminator
- Safer to use that standard UV transillumiators
- NO UV hazard to skin and eyes.
- NO DNA damage inherent to UV - No worries when cutting out bands for elution.
- Easy for use and gel cutting
- NO need to wear amber glasses.
- The THINNEST blue LED illuminator in the world.
- Strong blue LED for excitation.
- Uniform: <10% coefficient of variance (CV) in the central viewing area.
- Compact and Light: 30 mm in height
- Wide applications other than DNA/RNA gel visualization, such as fluorescent proteins.
- Sensitive for a wide range of fluorphores: DNA SafeStain, GelGreen, GelRed, EthBr, SYBR® Safe, SYBR Gold, SYBR Green I® & II, SYPRO® Rudy, SYPRO® Orange, Coomassie Fluor Orange stains, and Lumitein Protein Gel Stain.
The UltraSlim® LED Illuminator is designed for viewing stained gels on the laboratory bench, or within gel documentation systems. Safer lighting from the LED source inside the instrument produces blue light with a narrow emission peak centered at approximately 470 nm, which is more effective for the excitation of most nucleic acid and protein stains. Viewing surface is 120mm x 70mm.
Minigel System 7cm x 8 cm & (1) 6 and (1) 10 tooth comb
Perfectly sized for rapid analysis of small analytes like PCR and RE fragments. This unit features a RapidCast gasketed tray for quick in-unit gel casting.
System Description
Horizontal gel electrophoresis minigel system for 7cm x 8cm minigels. Includes gasketed UVT gel tray with fluorescent ruler, and (1) 6 and (1) 10 tooth comb, 1.5 mm thickness. Comb substitutions are available. Four year manufacturer warranty.
The standard 0708 mini gel system includes a RapidCast™ gasketed gel tray for convenient gel casting right in the buffer chamber.
System features
The 0708 complete system includes these features:
- Heavy duty lower buffer chamber
- Interlock safety lid with attached leads
- Gasketed (cast in place) 7cm wide x 8cm long UV-transparent gel tray with built-in fluorescent ruler and 2 comb slots.
- One 1.5mm x 6 tooth comb
- One 1.5mm x 10 tooth comb