View:

Cytiva 3MM Chr paper is the world's most widely used blotting paper.

This acceptance and usage reflect the high quality, purity and consistency that are relied upon by researchers doing Southern, Northern and Western transfers. 3MM Chr paper is now available in the most widely used sizes. A medium thickness paper (0.34 mm) used extensively for blotting in electrophoresis for lifting of sequencing gels.

GB004
A thick gel blotting paper (1.0 mm), used for wicking purposes only. Provides higher absorbency and more consistent wicking than paper towels. Recommended for applications where fewer layers of gel blotting paper must still ensure a high capacity. Fewer layers of blotting paper reduce the risk of trapping air bubbles. Recommended for capillary blotting of nucleic acids.

GB005
An extra-thick (1.2 mm ), highly absorbent paper recommended for applications where fewer layers of blotting paper must siill ensure a high capacity. Recommended for semi-dry blotting of proteins.

17 Chr
A thick (0.92 mm) and highly absorbent paper.

31 ET
An extremely fast and thick paper (0.5 mm) with a fairly soft surface.

Features and Benefits

  • Pure cellulose produced entirely from the highest quality cotton linters with no additives of any kind. Ensures that no contamination will occur during the transfer steps
  • Manufactured and tested specifically for chromatographic techniques. This ensures the wicking capability and uniformity of capillary action that is important in obtaining clean and even transfers during blotting
  • Cytiva 3MM Chr is considered the industry standard for blotting procedures
  • Convenient sizes available in sheets precisely cut to the most popular gel and transfer membrane sizes. Allows "out-of-the-box" usage and eliminates sheet-to-sheet variations
Item#:
ASBLOTPAP4

3MW is used widely in nucleic acid and protein research for blotting, wicking, spacers, and gel drying due to its purity, quality and consistent results. Uniform capillary action provides even wicking and enables gel transfers to be lifted RELIABLY from glass supports.

Item#:
ASBLOTPAP1

Cytiva 3MM Chr paper is the world's most widely used blotting paper.

This acceptance and usage reflect the high quality, purity and consistency that are relied upon by researchers doing Southern, Northern and Western transfers. 3MM Chr paper is now available in the most widely used sizes. A medium thickness paper (0.34 mm) used extensively for blotting in electrophoresis for lifting of sequencing gels.

GB004
A thick gel blotting paper (1.0 mm), used for wicking purposes only. Provides higher absorbency and more consistent wicking than paper towels. Recommended for applications where fewer layers of gel blotting paper must still ensure a high capacity. Fewer layers of blotting paper reduce the risk of trapping air bubbles. Recommended for capillary blotting of nucleic acids.

GB005
An extra-thick (1.2 mm ), highly absorbent paper recommended for applications where fewer layers of blotting paper must siill ensure a high capacity. Recommended for semi-dry blotting of proteins.

17 Chr
A thick (0.92 mm) and highly absorbent paper.

31 ET
An extremely fast and thick paper (0.5 mm) with a fairly soft surface.

Features and Benefits

  • Pure cellulose produced entirely from the highest quality cotton linters with no additives of any kind. Ensures that no contamination will occur during the transfer steps
  • Manufactured and tested specifically for chromatographic techniques. This ensures the wicking capability and uniformity of capillary action that is important in obtaining clean and even transfers during blotting
  • Cytiva 3MM Chr is considered the industry standard for blotting procedures
  • Convenient sizes available in sheets precisely cut to the most popular gel and transfer membrane sizes. Allows "out-of-the-box" usage and eliminates sheet-to-sheet variations
Item#:
ASBLOTPAP5

Protran nitrocellulose membranes are the most frequently specified transfer media in the world for a wide range of applications. Protran membranes are manufactured using 100% pure nitrocellulose to ensure the highest binding capacity possible. Other membranes referred to as "nitrocellulose" may actually contain large amounts of cellulose acetate, which will lower the protein binding capacity. In addition to high binding capacity, Protran nitrocellulose membranes inherently have very low background. The superior surface properties of the membrane guarantees superior signal-to-noise ratios, without the need for stringent washing conditions. Unlike PVDF membranes, Protran nitrocellulose requires no methanol pre-wetting step. This makes it the membrane of choice for proteins that prefer aqueous environments. Prior to transfer, the membrane is simply wet in water and then in the transfer buffer, with no other necessary pre-treatment steps. Protran membranes exhibit the best handling strangth of all pure nitrocellulose membranes.
Features:

  • High binding capacity (80-150g/cm2) of proteins and nucleic acids.
  • 100% pure nitrocellulose, with no cellulose acetate added, ensures the highest binding capacity possible.
  • Compatible with virtually all standard detection methods.
  • Low background - NC surface properties guarantee superior signal-to-noise ratios.
  • Triton-free matrix with low extractable levels will support the cell growth essential for colony blotting, plaque lifts, and tissue culture applications.
  • Available in many sizes and formats to fit different transfer devices and gel chambers.

Grade

Pore Size

BA75

0.05µm

BA79

0.1µm

BA83

0.2µm

BA85

0.45µm

Item#:
ASNITROCELL45

Nitrocellulose Membranes

Combining the advantages of high protein binding capacity with low background and high membrane stability, which ensures easy handling.

Ideal for western blotting, DNA blotting as well as dot or slot blots. They have been optimized for all protein blotting systems, such as electro transfer, semi-dry or simple capillary blotting

 

Specifications:

 

11306

11327

Dimensions

300 mm × 3 m

300 mm × 3 m

Flow rate

70 mL/min/cm²/bar (Water)

25 mL/min/cm²/bar (Water)

Pore size

0.45 µm

0.22 µm

Wettability

Hydrophilic

Hydrophilic

Grade

11306

11327

Packaging

Non-sterile, bulk packed

Non-sterile, bulk packed

Pack Size

1

1

Color

White

White

Filter Type

Blotting Membranes

Blotting Membranes

Filter Format

Reels

Reels

Bubble point

2.4 bar

4.2 bar

Burst pressure

0.2 bar

0.8 bar

Membrane thickness

130 µm

130 µm

Filter Material

Cellulose Nitrate (CN)

Cellulose Nitrate (CN)

Application

Blotting

Blotting

Item#:
ASNITRO

Protran nitrocellulose membranes are the most frequently specified transfer media in the world for a wide range of applications. Protran membranes are manufactured using 100% pure nitrocellulose to ensure the highest binding capacity possible. Other membranes referred to as "nitrocellulose" may actually contain large amounts of cellulose acetate, which will lower the protein binding capacity. In addition to high binding capacity, Protran nitrocellulose membranes inherently have very low background. The superior surface properties of the membrane guarantees superior signal-to-noise ratios, without the need for stringent washing conditions. Unlike PVDF membranes, Protran nitrocellulose requires no methanol pre-wetting step. This makes it the membrane of choice for proteins that prefer aqueous environments. Prior to transfer, the membrane is simply wet in water and then in the transfer buffer, with no other necessary pre-treatment steps. Protran membranes exhibit the best handling strangth of all pure nitrocellulose membranes.
Features:

  • High binding capacity (80-150g/cm2) of proteins and nucleic acids.
  • 100% pure nitrocellulose, with no cellulose acetate added, ensures the highest binding capacity possible.
  • Compatible with virtually all standard detection methods.
  • Low background - NC surface properties guarantee superior signal-to-noise ratios.
  • Triton-free matrix with low extractable levels will support the cell growth essential for colony blotting, plaque lifts, and tissue culture applications.
  • Available in many sizes and formats to fit different transfer devices and gel chambers.

Grade

Pore Size

BA75

0.05µm

BA79

0.1µm

BA83

0.2µm

BA85

0.45µm

Item#:
ASNITROCELL2
View: