ILP Deep Well Round Well, U-Bottom Glass Coated Plates – 96
Glass coated, polypropylene microplates. The 200 nm thick coating of silicone dioxide creates a cradle of non-binding and inert glass to protect your sample.
- SiO2 coating helps to:
- Reduced binding
- Increase chemical resistance
- Protect the same from any potential compounds leached from the plastic.
Plate design
- Mid-height to maximize storage, utilizing 30-40% less vertical space, allowing for more storage in freezers, automated loaders, under the hood, and other locations where space is at a premium
- Automation friendly design – sturdy and warp resistant with ultra-flat surfaces and rigid construction
- Stacking lugs to help prevent toppling
- Raised rims protect from cross contamination, minimize sample loss during storage, and make for enhanced sealing with adhesive films, silicone mats, or heat sealing films
- Individually wrapped in medical grade Tyvek peel-packs
- Made from Virgin Polypropylene; no mold release agents or regrind
- RNase, DNase, DNA, and Pyrogen Free Certification
Specifications
Number of Wells | 96 |
Number of Plugs | 96 |
Plug Shape | Round – U |
Well Shape Top | Round |
Well Shape Bottom | Round – U |
Material | USP Class VI Polypropylene |
Adhesive Material | SiO2; 0.0079 Mil |
Color | Natural |
Alphanumeric | Molded in |
Compliance | ANSI/SBS 6-2012 |
Surface Treatment | SiO2 |
Certified | DNase-/RNase-/Pyrogen-Free |
Overall Height | 1.30 In. | 33.00 mm |
Well Depth | 1.21 In. | 30.84 mm |
Overall Length | 5.03 In. | 127.78 mm |
Adhesive Thickness | SiO2; 0.0079 Mil |
Width | 3.37 In. | 85.48 mm |
Top Width | 3.24 In. | 82.24 mm |
Well Diameter Bottom | 0.16 In. | 4.12 mm |
Well Diameter Top | 0.28 In. | 7.00 mm |
Top Length | 4.90 In. | 124.53 mm |
Well Bottom To Deck | 0.05 In. | 1.30 mm |
Max Vol. | 1.22 mL |
Working Vol. | 1.1 mL |
Vol. With Mat Lid | 1.0 mL |
Plug Depth | 1.21 In. | 30.84 mm |
Plug Diameter | 0.16 In. | 4.12 mm |
Autoclavable | 121ºC at 15 psi, 15 min. (249.8ºF) |
Max RCF | 4,000 RCF |
Max Temp. | 120ºC (248ºF) |
Min Temp. | -80ºC (-112ºF) |
ILP Deep Well Round Well, V-Bottom Glass Coated 33 mm Plates - 96
These round deep-well V-bottom glass-coated plates combine working volume with an automation-friendly design. Sturdy and warp-resistant design with ultra-flat surfaces and rigid construction make this plate ideal for high throughput screening, sample collection, compound storage, screening, and combinatorial chemistry applications. It is compatible with stackers, grippers, heater/cooler blocks, and other instruments that comply with the ANSI/SLAS 2004-1 (SBS) footprint.
Raised rims on each well help protect from cross-contamination, minimize sample loss during storage, and make for enhanced sealing with adhesive films, silicone mats, or heat-sealing films. Manufactured of inert, chemically resistant, and exceptionally clear virgin polypropylene. Made from medical grade virgin polypropylene (no mold release agents or regrind); certified RNase, DNase, DNA, and Pyrogen Free.
- Uniform wall thickness
- Easy well identification with molded-in alpha-numeric position markings
- Raised rims for easy and secure sealing with adhesive films, silicone mats, or heat-sealing films
- Raised rims help protect from cross contamination
Specifications
Number of Wells | 96 |
Number of Plugs | 96 |
Plug Shape | Conical -V |
Well Shape Top | Round |
Well Shape Bottom | Conical -V |
Material | USP Class VI Polypropylene |
Adhesive Material | SiO2; 0.0079 Mil |
Color | Natural |
Alphanumeric | Molded in |
Compliance | ANSI/SBS 6-2012 |
Surface Treatment | SiO2 |
Certified | DNase-/RNase-/Pyrogen-Free |
Overall Height | 1.30 In. | 33.00 mm |
Well Depth | 1.21 In. | 30.84 mm |
Overall Length | 5.03 In. | 127.78 mm |
Adhesive Thickness | SiO2; 0.0079 Mil |
Width | 3.37 In. | 85.48 mm |
Top Width | 3.24 In. | 82.24 mm |
Well Diameter Bottom | 0.16 In. | 4.12 mm |
Well Diameter Top | 0.28 In. | 7.00 mm |
Top Length | 4.90 In. | 124.53 mm |
Well Bottom To Deck | 0.05 In. | 1.30 mm |
Max Vol. | 1.1 mL |
Working Vol. | 1.0 mL |
Vol. With Mat Lid | 800 uL |
Plug Depth | 1.21 In. | 30.84 mm |
Plug Diameter | 0.16 In. | 4.12 mm |
Autoclavable | 121ºC at 15 psi, 15 min. (249.8ºF) |
Max RCF | 4,000 RCF |
Max Temp. | 120ºC (248ºF) |
Min Temp. | -80ºC (-112ºF) |
Film-Sealing Paddles
- Sealing paddles complete the application of sealing films
- Press the film with the sealing paddle to assure a secure uniform seal around all wells of a microplate
- Paddles fit within the edge of raised-rim plates
- Sealing Roller completes the application of sealing films
- Press the film with the accessory plate roller assure a secure uniform seal around all wells of a microplate
Proudly made in the USA! Click here for more made in America products!
Multi-Swipe™ Plate-Sealing Paddles
For sealing flat-top and raised-rim plates.
Application: Plate-sealing
Material: Polyethylene
The Multi-Swipe plate-sealing paddle ensures a secure and uniform, pressure-sensitive seal around all wells and is an economical alternative to plate rollers. Plate-sealing paddles are designed for use with all plate types.
- Reusable, recyclable
- The semi-soft, pliable sealing surfaces prevent the film/foil from being torn or ripped
- The non-flat contoured side is designed to go down to the plate; the center raised textured surface provides a non-slip finger hold
- Features two sealing surfaces: the shorter length fits inside the walls of raised-rim plates; the longer length is ideal for flat-top and deep-well plates
- Features two unique sized corner radii: 1/8 inch (0.3175 centimeter) and 1/16 inch (0.1588 centimeter) to seal around the plate perimeter; the tighter radii is for use with raised-rim PCR plates
Helpful Tips
- The printed side is used to seal the film to the plate
- Multiple swipes of the sealing paddle in both directions is highly recommended
- A 10 minute or greater dwell time at room temperature before processing increases the film-to-plate bond
Proudly made in the USA! Click here for more made in America products!
Hoefer® Mighty Small Transfer Tank
The TE22 Mighty Small Transfer Tank quickly and efficiently transfers proteins and nucleic acids from small gels to nylon, nitrocellulose or PVDF membranes. Maximum Gel Size 9 x 10 cm.
- Transfer as many as four small gels, up to 9 x 10 cm in less than an hour
- Uniform and strong electric field—supports efficient and even transfers
- Color-coded, easy to assemble and load cassettes—ensures proper orientation during transfer
- Superior tank design allows the cassettes to apply equal pressure across the stack - prevents gel distortion
- Built-in ceramic heat exchanger—provides excellent temperature control when used with an external cooling water bath
- Built-in alumina-covered cooling channel provides excellent temperature control with no more than a 5°C temperature increase during a typical run
Hoefer® Mighty Small Transfer Tank Includes
- Lower Chamber with Heat Exchanger, 1/ea
- Safety Lid with High Voltage Leads, 1/ea
- Electrode Panels, 2/pk
- Cassettes, 4/pk
- Foam Sponges, 6 mm thick, 4/pk
- Foam Sponges, 3 mm thick, 8/pk
- Cassette Hook, 1/ea
- Blotter Paper (9 x 10.5 cm), 25 sheets/pk
Hoefer® Mini Electrophoresis and Western Blot Package
Save time and money with a combination package.
- SE260-10A-75 Mighty Small II Mini Deluxe Vertical Unit
- TE22 Mighty Small Mini Transfer Tank
- PS300B 300 V, 500 mA, 90 W Power Supply
Specifications
Capacity | Up to four 9 x 10 cm gels |
Max. Power | 100 V, 500 mA, 50 W |
Max. Temp. | 113ºF | 45°C |
Indoor Use | 39.2 to 104ºF | 4 to 40°C |
Humidity | Up to 80% |
Dims (D x W x H) | 6.50 x 5.51 x 9.45 In. | 16.5 x 14 x 24 cm |
Weight | 4.441 lb | 2.00 kg |
Proudly made in the USA! Click here for more made in America products!
Hoefer® Standard Transfer Tank
The TE42 Standard Transfer Tank quickly and evenly transfers proteins and nucleic acids from polyacrylamide or agarose gels onto nylon, nitrocellulose, or PVDF membranes. The four slot design of the TE42 enables either cooled or non-cooled protein or nucleic acid transfers. The optional heat exchange module is easily incorporated into the TE42 enabling transfer of up to 2 gels simultaneously. When used without the optional heat exchange module, up to four gels can be transferred at one time.
- Uniform and strong electric field—supports efficient and even transfers
- Color-coded, easy to assemble cassettes—ensures proper orientation during transfer
- Superior tank design allows the cassettes to apply equal pressure across the stack - prevents gel distortion
- Optional TE47 heat exchanger—provides excellent buffer temperature control when used with an external cooling water bath
- Heat exchanger from an SE600 series electrophoresis unit can be substituted for the TE47 heat exchanger.
Hoefer® Standard Transfer Tank Includes
- Lower Chamber, 1/ea
- Safety Lid with High Voltage Leads, 1/ea
- Electrode Panels, 2/pk
- Cassettes, 2/pk
- Foam Sponges, 6 mm thick, 2/pk
- Foam Sponges, 3 mm thick, 4/pk
- Cassette Hook, 1/ea
- Blotter Paper (14.5 x 21.5 cm), 25 sheets/pk
Specifications
Capacity | Up to four 15 x 21 cm gels (w/out cooling) Up to two 15 x 21 cm gels (w/ cooling) |
Max. Power | 100 V, 2 A, 200 W |
Max. Temp. | 113ºF | 45°C |
Indoor Use | 39.2 to 104ºF | 4 to 40°C |
Humidity | Up to 80% |
Dims (D x W x H) | 12.01 x 3.15 x 5.12 In. | 30.5 x 8 x 13 cm |
Proudly made in the USA! Click here for more made in America products!
Hoefer® Standard Transfer Tank with Cooling Chamber
TE62 Standard Transfer Tank with Cooling Chamber quickly and evenly transfers proteins and nucleic acids from polyacrylamide or agarose gels onto nylon, nitrocellulose, or PVDF membranes while providing excellent temperature control.
The TE62 is designed to accept up to four cassettes simultaneously with cooling. Each cassette holds a 15 x 21 cm gel, or as many as four 7 x 10 cm mini gels.
- Uniform and strong electric field—supports efficient and even transfers
- Color-coded, easy to assemble cassettes - ensures proper orientation during transfer
- Superior tank design allows the cassettes to apply equal pressure across the stack - prevents gel distortion
- Built-in ceramic heat exchanger - provides excellent temperature control when used with an external cooling water bath
Hoefer® Standard Transfer Tank with Cooling Chamber Includes
- Lower Chamber with Heat Exchanger, 1/ea
- Safety Lid with High Voltage Leads, 1/ea
- Electrode Panels, 2/pk
- Cassettes, 4/pk
- Foam Sponges, 6 mm thick, 4/pk
- Foam Sponges, 3 mm thick, 8/pk
- Cassette Hook, 1/ea
- Blotter Paper (14.5 x 21.5 cm), 25 sheets/pk
Specifications
Capacity | Up to four 15 x 21 cm gels Up to sixteen 7 x 10 cm gels |
Max. Power | 100 V, 2 A, 200 W |
Max. Temp. | 113ºF | 45°C |
Indoor Use | 39.2 to 104ºF | 4 to 40°C |
Humidity | Up to 80% |
Dims (D x W x H) | 12.60 x 11.02 x 6.50 In. | 32 x 28 x 16.5 cm |
Proudly made in the USA! Click here for more made in America products!
Gel Crusher™ Spin Column
- Creates uniform gel fragments with no chunks
- Fits in standard microtubes
- Increases DNA yield
- For use in molecular cloning, PCR, restriction digestions, sequencing, and labeling protocols
- Fits 2 mL receiver tubes
MTC Bio’s Gel Crusher™ Spin Columns are designed to replace labor-intensive gel fragmentation steps (crush+soak method, etc.). Commonly used in molecular cloning, PCR, restriction digestions, sequencing, and labeling protocols, these spin columns can be used to fragment gel slices (typically cut with a gel extractor or razor blade) into smaller pieces.
These smaller uniform pieces will produce greater yields and can be easily pipetted using wide bore tips into an NaCl solution. This reduces the time to create a fine slurry for further elution, filtration, incubation, etc. Place the Gel Crusher™ column in the 2 mL microtube and centrifuge the column/tube assembly in a standard benchtop microcentrifuge for 5 minutes at maximum speed (generally approximately 15,000 x g).
The gel will be forced through the 600 uM holes into the 2 mL receiver tube. The crushed fragments will be small enough to be aspirated/dispensed through a pipette tip.
Reversible Racks
- Alphanumeric markings and are supplied in packs of 5.
- Choose 60 well (5 x 12) or 96 well (8 x 12) formats
- Reversible racks, accept 0.5 and 1.5 to 2.0 mL microtubes
- Alphanumeric marking on each well
- Made of polypropylene
Azure HRP Stripping Buffer
Works by removing the primary and secondary antibodies from the membrane
Stripping buffer for stripping and re-probing chemiluminescent Western blots.
- Provided as a 1x ready-to-use solution
- Size: 500mL
Azure Aqua Transfer Cell
Perform a quick 1 hour transfer or transfer overnight at a lower voltage
Aqua Transfer Cell is used for transferring two mini gels to membranes for Western blotting experiments (wet transfer). The transfer cassettes and electrode core are colored for directionality which makes transferring easy and straightforward.
Includes:
- 2 transfer cassettes
- 6 sponges
- 2 Azure Aqua cooling units
- Tank and upper lid with power cables
- Transfer Electrode Cores
Features
The transfer cassettes and electrode core are colored for directionality, making transferring easy and straightforward.
Chemical reagent compatibility
Keep all components of the Azure Aqua Transfer Cell away from chloroform, arenes (such as methylbenzene benzene), and acetone. Any damage caused by these reagents is not covered by the warranty policy.
Cleaning Instructions
Before using, wash all components with a neutral detergent and rinse well with ultra pure water.
Wash the electrode assembly, transfer cassettes, and buffer tank with a neutral detergent and warm water. Be careful to avoid damaging the platinum electrodes. Use warm water to rinse the sponges, and then rinse all components with distilled or ultra-pure water.
Specifications
Parameters | Azure Aqua Transfer Cell Specs |
Number of cassettes | 2 |
Buffer requirement | 1100 mL |
Electrode distance | 4 cm |
Electrode assembly size ( L x W x H) | 17.5 cm x 13.5 cm x 19 cm |
Transfer time | 60 minutes |
Cooling | Azure Aqua cooling unit |
Blotting area | 7.5 cm x 10 cm |
Buffer volume (with cooling unit) | 650 mL |
Buffer volume (without cooling unit) | 850 mL |
Unit dimensions (W x L x H) | 13.5 cm x 17.5 cm x 19 cm |
Tank buffer volume | 1100 mL |
Maximum gel size | 7.5 cm x 10 cm |
Gel capacity | 2 precast or handcast gels |
Weight | 1.8 lbs |
Recommended power supply | Azure Aqua Power Supply 600V |
Azure Transfer Buffer
This proprietary transfer buffer provides improved detection of low-abundance and post-translationally modified proteins.
High-efficiency protein transfer and increased protein retention on the membrane add up to more sensitive Western blots.
- Provided as a 50x concentrated solution. Sufficient for 50-100 blots
- Size: 500mL
Features
- High performance—increased protein retention on the membrane and fast transfer times result in more sensitive detection of low-abundance and post-translationally modified proteins
- Efficient—enhanced transfer efficiency for proteins of all sizes
- Fast—transfer proteins in less than 20 minutes vs. several hours required with traditional transfer buffers
- Convenient—use your existing wet transfer electrophoresis apparatus
Azure ChemiWriter ECL Pen
Chemiluminescent pen for blot annotation
The Azure ChemiWriter ECL Western blot annotation pen is a chemiluminescent marker that enables you to write or draw on your transfer membranes, resulting in a chemiluminescent signal on your markings once substrate is added. Contains a reagent that reacts with HRP substrates to produce chemiluminescence and also a blue dye to allow you to see markings as you write on the Western blot.
Use for tracing visible protein ladders or making identifying marks on your Western blots. Pen has two tips on each end: one fine-tipped for thin markings and one thicker for depositing more of the reagent.
Quantity: 1 pen
Features
Enables you to write or draw on your transfer membranes. A chemiluminescent signal will be detectable from your markings once chemiluminescent substrate is added.
- Use for tracing visible protein ladders or making identifying marks on your blots. Pen has two tips on each end: one fine-tipped for thin markings and one thicker for depositing more of the reagent.
- There are two heads to the pen, a fine point tip and a thicker chisel point tip.
- We recommend using the fine point tip to annotate the blot and mark protein ladders for detection.
- The chisel point of the pen can be used to deposit an increased amount of reagent on the blot for more intense signal.
- For best results we recommend annotating your blot after transfer and before starting your Western blotting protocol.
- Once annotated, the blot may be stored dry or wet, refrigerated or at room temperature.
- Storage: pen should be stored tightly closed at room temperature. ChemiWriter ECL reagent and blue ink markings on the blot are stable for at least three months.