Home  >  Liquid Handling  >  Pipettors and Tips  >  Labcon Tips  >  APT Automation Pipette Tips  > Labcon APT™ Automation Pipette Tips

Labcon APT™ Automation Pipette Tips

Item #: ASLABAPTTIPS 
Pfu DNA Polymerase

This product is no longer available, please contact us for other options.
 

Looking for other alternatives?

Visit our PR1MA Polymerase page for more options!



Pfu DNA Polymerase 
Pfu DNA polymerase is a heat stable DNA polymerase which has 5' 3' DNA polymerase and 3' 5' exonuclease (proofreading) activities. Pfu DNA polymerase retains the high fidelity, sensitivity and processivity with an error rate six-fold lower than Taq DNA polymerase, and significantly lower than the error rates of most other proofreading enzymes or DNA polymerase mixtures (1). This product is supplied with the unique Intact Genomics 10x PCR reaction buffer, containing MgCl2, which produces a final Mg2+ concentration of 1.5 mM, and 5X Magic Enhancer that enables efficient amplification of GC rich templates up to 84%. The physical purity of this enzyme is 98% as assessed by SDS-PAGE with Coomassie® blue staining.

Quality Control 
Quality control is performed following the production of each new lot of product to ensure that it meets the quality standards and specifications designated for the product. Each lot is repeatedly compared side-by-side with leading competitors to ensure our products outperform the competitor before product launching. 

Product Source
E. coli strain expressing a Pfu DNA Polymerase gene from Pyrococcus furiosus.

Contents & Storage

  1. Pfu DNA Polymerase
  2. 10x PCR Buffer with Mg²+
  3. 5x Magic Enhancer
  4. 10 mM dNTP (Cat. # 3312d, 3314d only)

Store all contents at -20 °C.

Storage Buffer 
50 mM Tris-HCl, 50 mM KCl, 1 mM DTT, 0.1 mM EDTA, 50% Glycerol, pH 7.5 @ 25 °C.

10X PCR Buffer with Mg2+ 
100 mM Tris-HCl pH 9.0, 15 mM MgCl, 100 mM KCl, 80 mM (NH4)2SO4, 0.5% Igepal CA 630

Unit Definition 
One unit is defined as the amount of enzyme that incorporates 10 nmoles of dNTP into acid-insoluble form in 30 minutes at 72 °C.

Protocol
1. Thaw 10x PCR Buffer, dNTP mix, primer solutions, 5x Magic Enhancer (if required) and mix thoroughly before use. 
2. Prepare a reaction mix according to the following table: The reaction mix typically contains all the components needed for PCR except the template DNA.

 

PCR reaction set up:

Template DNA

xµl (0.01-0.5µMg)

10x PCR Buffer

10.0µl

dNTP (10 mM)

2.0µl

Forward Primer

xµl (0.1- 0.5µMM)

Reverse Primer

xµl (0.1- 0.5µMM)

5x Magic Enhancer (optional)

20µl

Pfu DNA Polymerase (5 U/µl)

0.5µl

H2O up to

100.0µl

3. Mix the reaction mixture thoroughly.
4. Add template DNA to the individual PCR tubes containing the reaction mixture. 
5. Program the thermal cycler according to the manufacturerâs instructions. A typical PCR cycling program is outlined in the following table.

PCR cycling conditions:

Steps

Temp.

Time

Cycles 

Initial denaturation

95 °C

3-5 min

1

Denaturation

94 °C

30-60 sec 

  

25-35

Annealing

52-66 °C

30-60 sec 

Extension

72-74 °C

1-2 min 

Final extension

72-74 °C

10 min 

1

Hold 

4-12 °C

â

6. Place the PCR tubes in the thermal cycler and start the cycling program.

PNPCRREAG

Magnesium
Mg
Dye
No Dye
Enzymes
Intact Genomics
Pkg
Indiv
Type
Proofreading
 
Item#:
ASPRIMADNAPOL
 
SKU Number Tip Fit Lid Type Vol Sterile Qty Price Quantity Add to Cart
8007-200-008-9 For Workstations Refills 30 uL Non-Sterile 8 refills of 7,680 tips
14813.58
Each
8015-200-020-9 For Workstations Refills 50 uL Non-Sterile 8 refills of 2,688 tips
2770.57
Each
8016-200-020-9 For Workstations Refills 200 uL Non-Sterile 8 refills of 1,920 tips
1979.85
Each
8010-200-020-9 For Biotek Instruments Workstations Refills 50 uL Non-Sterile 8 refills of 2,688 tips
2702.35
Each
8020-200-020-9 For Biotek Instruments Workstations Refills 200 uL Non-Sterile 8 refills of 1,920 tips
1714.13
Each
8021-200-020-9 For Beckman Multimek Workstations Refills 200 uL Non-Sterile 8 refills of 1,920 tips
1805.25
Each
8015-690-008-9 For Workstations Racked 50 uL Non-Sterile 50 racks of 96 tips
889.47
Each
8124-695-000-9 For Beckman FX and NX AP96 Workstations Racked 90 uL Sterile with Aerosol Filter 50 racks of 96 tips
1139.27
Each
8024-695-010-9 For Beckman FX and NX AP96 Workstations Racked 90 uL Sterile 50 racks of 96 tips
801.30
Each
8024-690-010-9 For Beckman FX and NX AP96 Workstations Racked 90 uL Non-Sterile 50 racks of 96 tips
764.70
Each
8114-695-000-9 For Beckman FX and NX AP96 Workstations Racked 100 uL Sterile with Aerosol Filter 50 racks of 96 tips
1138.66
Each
8014-695-010-9 For Beckman FX and NX AP96 Workstations Racked 100 uL Sterile 50 racks of 96 tips
801.01
Each
8014-690-010-9 For Beckman FX and NX AP96 Workstations Racked 100 uL Non-Sterile 50 racks of 96 tips
764.11
Each
8117-695-000-9 For Beckman FX and NX AP96 Workstations Racked 220 uL Sterile with Aerosol Filter 50 racks of 96 tips
1131.16
Each
8020-695-028-9 For Biotek Instruments Workstations Racked 200 uL Sterile 50 racks of 96 tips
954.55
Each
8020-690-028-9 For Biotek Instruments Workstations Racked 200 uL Non-Sterile 50 racks of 96 tips
874.13
Each
8017-695-010-9 For Beckman FX and NX AP96 Workstations Racked 220 uL Sterile 50 racks of 96 tips
803.96
Each
8017-690-010-9 For Beckman FX and NX AP96 Workstations Racked 220 uL Non-Sterile 50 racks of 96 tips
767.12
Each
8005-695-009-9 For Beckman FX and NX AP384 Workstations Racked 30 uL Sterile 50 racks of 384 tips
4735.05
Each
8005-690-009-9 For Beckman FX and NX AP384 Workstations Racked 30 uL Non-Sterile 50 racks of 384 tips
4336.53
Each
8010-250-000-9 For Biotek Instruments Workstations Mini Refills 50 uL Non-Sterile 8 refills of 672 tips
714.26
Each
8020-250-000-9 For Biotek Instruments Workstations Mini Refills 200 uL Non-Sterile 8 refills of 480 tips
336.79
Each
LabCon APT Automation Tip
Labcon APT™ Automation Pipette Tips
Special Order
Quantity: