S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
ActionsFeatures:
- New Rugged Construction - ribbed high strength aluminum body, magniformed necktube design, and more durable paint.
- Convenient Storage Systems - rack index location ring and internal spider, computer compatible box storage is ideal for simple inventory management.
- Super vacuum performance with super insulation provides maximum holding times.
- Security - Accessory low-level alarm is available for more valuable samples.
- Mobility - Roller bases are available.
- LS6000 available with AutoTend Controller
- Warranty: 2 years on vacuum, 1 year on electronic
Models |
LS750 |
LS3000 |
LS4800 |
LS6000 |
||
Static Holding Time days(1) |
130 |
106 |
153 |
194 |
||
Working Time days (2) |
80 |
66 |
96 |
120 |
||
Evaporation Rate (1)liters/days |
0.27 |
0.76 |
0.85 |
0.84 |
||
Liquid Nitrogen Capacity - liters |
35 |
81 |
130 |
165 |
||
Weight Empty |
- lbs.-kg. |
39/17.7 |
70/31.8 |
90/40.9 |
121/55.0 |
|
Weight Full (3) |
- lbs.-kg. |
101.3/46.0 |
214.2/97.4 |
312.4/146.1 |
410.0/186.4 |
|
Neck Diameter |
- in. - mm. |
4.7/119 |
8.5/216 |
8.5/216 |
8.5/216 |
|
Overall Height |
- in. - mm. |
26.8/681 |
28.8/731 |
35.1/892 |
39.0/991 |
|
Overall Diameter |
- in. - mm. |
18.8/478 |
26.9/683 |
26.9/683 |
26.9/683 |
|
Number of Racks |
|
6 |
6 |
6 |
6 |
|
Number of Shelves/Rack |
5 |
5 |
8 |
10 |
||
2 ml vial capacity (4) |
750 |
3000 |
4800 |
6000 |
||
Box Size - |
Shape Size in. Size mm. Vials per box |
Square 3.0 x 3.0 76x76 25 |
Square 5.0 x 5.0 127x127 100 |
Square 5.0 x 5.0 127x127 100 |
Square 5.0 x 5.0 127x127 100 |
|
Roller Base |
R033-8C00 |
R05K-8C00 |
R05K-8C00 |
R05K-8C00 |
||
Cryo-Sentry Level Alarm |
R036-8C30 |
RS30-8C40 |
R05K-8C26 |
RS60-8C26 |
Item# | |||
N-374180 | Polycarb Boxes, 25 Cells, | 36/cs | |
RS30-8C40 | Cryo-Sentry Level Alarm, | for LS3000 | |
RS30-9C16 | Necktube Core, for LS3000 | ||
RS60-8C26 | Cryo-Sentry Level Alarm, | for LS6000 | |
RS60-9C16 | Necktube Core, for LS6000 | ||
R033-8C00 | Roller Base for 35LD, 50LD, | 34XT, 34HC, 35HC, 35VCH & | LS750 Cryogenic containers |
R036-8C30 | Cryo-Sentry Level Alarm, | for LS750 and VHC35 | |
R036-9C16 | Necktube Core, for LS750 and | VHC35 | |
R036-9C34 | Rack, 5 Shelf, for LS750, | No Boxes | |
R05K-8C00 | Roller Base for LS-Series | ||
R05K-8C26 | Cryo-Sentry Level Alarm, | for LS4800 | |
R05K-9C16 | Necktube Core, for LS4800 | ||
R24K-9C44 | Polycarb Boxes, 100 Cells, | 24/cs | |
R24K-9C45 | Polycarb Boxes, 81 Cells, | 24/cs |
- Tubes are packaged 50/pk, 500/box for a total of 2,000 tubes per case.
- Made from high quality virgin polypropylene.
- Fits all standard boxes.
- Screw cap
- Available internal and external thread.
Features:
- Temperature Control Available
- Temperature Monitor Available
- Intuitive Electronic Touch Controls
- See Controller Technical Manuals at taylorwharton.com
- All Stainless Steel Vacuum Vessel
- Modular Design
- Durable Powder Coated Cabinet
- Caster Mounted Electronic Touch Controls
- Superior Vacuum Performance
- Warranty: 2 years on vaccum, 1 year on electronic
Models | 3K | 10K | 24K | 38K |
Static Holding Time day (1) | 19 | 33 | 52 | 74 |
Working Time days (2) | 12 | N/A | N/A | N/A |
Evaporation Rate (1) liters/days | 2.5 | 5 | 7 | 8 |
Liquid Nitrogen Capacity - liters | 48 | 165 | 365 | 590 |
Weight Empty | 42.0lbs/19.1kg | 245lbs/111kg | 405lbs/184kg | 565lbs/256kg |
Weight Full | 125lbs/56.7kg | 537lbs/243kg | 1046lbs/474kg | 1616lbs/733kg |
Neck Diameter | 14.0in/356mm | 21.0in/533mm | 31.0in/787mm | 39.0in/991mm |
Overall Height | 29.7in/754mm | 44.0in/1118mm | 44.0in/1118mm | 49.0in/1245mm |
Overall Diameter | 15.4in/391mm | 23.1x30.5in(3)/587x775mm | 34.0x38.5in(3)/864x965mm | 42.0in(4)/1067mm |
Usable height - Internal | 19.2in/488mm | 29.0in/737mm | 29.0in/737mm | 29.0in/737mm |
Internal Diameter | 14.0in/356mm | 21.0in(5)/533mm | 31.0in(5)/787mm | 39.0in(5)/991mm |
2ml Plastic Vials (6) | 3024 | 10400 | 24050 | 38350 |
Number of 100/81 Cell Racks | N/A | 7 | 17 | 28 |
Number of 25 Cell Racks | N/A | 4 | 6 | 6 |
Number of Shelves | N/A | 13 | 13 | 13 |
Box Size............................Shape | Triangle | Square Square | ||
.......................................Size in. | 6.75x 6.87(7) | 5 x 5 (8)/3 x 3 (8) | ||
.......................................Size mm | 171x175 | 127 x 127/76 x 76 | ||
.......................................Vials per box | 56 | 100/25 | ||
Blood Bag Capacity | ||||
Fenwal #4R5461 - 9953 | N/A | 235 | 535 | 870 |
Fenwal #4R5462 - 9955 | N/A | 185 | 475 | 680 |
Fenwal #4R5451 | N/A | 343 | 805 | 1407 |
Stericon #RCM91D | N/A | 235 | 360 | 560 |
Chartmed # 7005-2 | N/A | 105 | 216 | 536 |
Gambro #DF700 | N/A | 88 | 200 | 320 |
Gambro #DF200 | N/A | 192 | 496 | 496 |
0.55cc Straws, 10 per goblet, 2013mm goblets per can, Two tier turn-table inventory control system | 4680 | 44000 | 59400 | 114000 |
Roller Base | R018-8C00 | N/A | N/A | N/A |
Cryo-Sentry Level Alarm | N/A | N/A | N/A | N/A |
(1) Evaporation rate and static holding time are nomial. Actual rate may be affected by the nature of the contents, atmospheric conditions, container history and manufacturing tolerances.
(2) Work time is an arbitrary, reference-only value to estimate container performance under the actual operating conditions.
(3) Maximum required clearence (with lid open) for the 10K is 69.0 (1753mm); 24K is 76.0 in (1930mm). Depth with lid open for 10K, is 34.0in (864mm); 24K is 48.5in (1232mm)
(4) Maximum depth 55.0in (1397mm). Maximum height 90.0in (2286mm) with lid open.
(5) Temperture Gradient Suppression System reduces internal diameter by approx. 1/4in (6.4mm)
(6) 2.0ml vial sizw: 12.55mm O.D. internal thread
(7) 6-9-2
(8) The 10K/24K/38K containers utilize both the 5in x 5in (127mm x 127mm) 100/81 cell box and the 3in x 3in (76mm x 76mm) 25 cell box
Cryo Express (CX) are designed to safely transport a wide variety of materials at cryogenic temperatures. The unique absorbent material prevents a liquid spill if the unit is tipped over. Storage temperature inside the shipping cavity remains at approximately 150° C until the liquid nitrogen evaporates from the absorbent material.
Features:
- Advanced Concept Absorbent enables faster charging.
- Complies with IATA regulation
- New rugged construction includes dependable, stronger, magniformed necktube design, ribbed high strength aluminum body, and more durable paint system.
- Superior vacuum performance with super insulation provides maximum holding times.
- Optional storage accessories include a five shelf rack system for the CX500
- Lockable lids.
- Warranty: 2 years on vacuum, 1 year on electronic
Models |
CX100 |
CXR100 |
CXR500 |
|
Static Holding Time days(1) |
24 |
16 |
11 |
|
Working Time days(2) |
17 |
11 |
7 |
|
Evaporation Rate(1)liters/days |
0.18 |
0.23 |
0.60 |
|
Liquid Nitrogen Adsorbed liters |
4.4 |
3.7 |
6.7 |
|
Weight Empty |
lbs.kg. |
11.7 5.3 |
11.7 5.3 |
30 13.6 |
Weight Full(3) |
lbs.kg. |
19.5 8.9 |
18.3 8.3 |
43.7 19.8 |
Neck Diameter |
in. mm. |
2.78 71 |
3.58 91 |
8.5 216 |
Overall Height |
in. mm. |
18.4 467 |
19.4 493 |
26.9 683 |
Overall Diameter |
in. mm. |
9.2 234 |
234 9.2 |
15.5 391 |
Number of Canisters |
|
1 |
1 |
N/A |
Canister Dimensions |
in.mm. |
2.64x11.0 67x279 |
2.64x11.0 67x279 |
N/A N/A |
Number of 1.2 ml & 2.0 mlvials (5/cane)(4) |
85 |
85 |
500 |
|
Number of 1.2 ml & 2.0 ml vials (6/cane)(4) |
102 |
102 |
500 |
|
Number of 1/2 straws (10/cane) |
280 |
280 |
N/A |
|
Number of 1/2 cc straws Bulk ( 1 level) |
490 |
490 |
N/A |
|
Number of 1/2 cc straws Bulk ( 2 levels) |
980 |
980 |
N/A |
|
Padded carton |
37019277 |
N/A |
Item# | ||
CP70-9C18 | Necktube Core, for CX500 or | CXR500 |
CP70-9C44 | Rack, for Blood Bag, for CX500 | |
CXR100-9C01 | Necktube Core, for CXR100 | |
CXR100-9C24 | Canister, for CXR100 | |
CXR100-9C30 | Replacement Adsorbent Set, | for CXR100 or CXR500 |
CX10-8C00 | Shipping Case, for CX100 | |
RS30-9C44 | Rack, 5 Shelf, for CXR500, | No Boxes |
R005-9C21 | Necktube Core, for CX100 | |
R005-9C24 | Canister, for CX100 | |
R24K-9C44 | Polycarb Boxes, 100 Cells, | 24/cs |
3701-9277 | Shipping Case, for CX100 | Lightweight padded carton |
LD Series
The LD Series of cryogenic dewars are designed for storing and dispensing small amounts of liquid nitrogen. The series includes a beaker style dewar with a wide mouth (LD5) and pitcher-style model for easy pouring (LD4).
Features
High performance modern construction and advanced insulation materials assure high thermal efficiency
New rugged construction, ribbed high strength aluminum body, magniformed necktube design, and more durable paint system
Easy operation lightweight snap-on cap and necktube assures tight closure and easy access, convenient
larger handles
Superior vacuum performance with super insulation provides maximum holding times
Optional equipment includes liquid withdrawal device, tipping stand, dippers and roller base (for some models)
Warranty: 2 years on vaccum, 1 year on electronic
Models |
LD4 |
LD5 |
LD10 |
LD25 |
Classic 25 |
LD35 |
LD50 |
||||
Static Holding Time days(1) |
10 |
6 |
45 |
109 |
119 |
152 |
122 |
||||
Working Time days(2) |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
||||
Evaporation Rate(1)liters/days |
0.40 |
0.77 |
0.22 |
0.23 |
0.21 |
0.23 |
0.41 |
||||
Liquid Nitrogen Capacity - liters |
4 |
5 |
10 |
25 |
25 |
35 |
50 |
||||
Weight Empty |
- lbs.-kg. |
6.6 3.0 |
6.9 3.1 |
14.5 6.6 |
23.2 10.5 |
19 8.6 |
35.1 16.0 |
38.7 17.6 |
|||
Weight Full |
- lbs. - kg. |
13.7 6.2 |
15.8 7.2 |
32.3 14.7 |
67.7 30.8 |
63.5 28.9 |
97.4 44.3 |
127.7 58.0 |
|||
NeckDiameter |
- in. - mm. |
1.2 30 |
5.6 142 |
2.0 51 |
2.5 64 |
2.0 51 |
2.5 64 |
2.5 64 |
|||
Overall Height |
- in. - mm. |
17.0 432 |
17.5 445 |
23.5 597 |
25.8 655 |
22.9 582 |
26.3 668 |
32.4 823 |
|||
OverallDiameter |
- in. - mm. |
7.6 193 |
7.6 193 |
11.4 290 |
15.6 396 |
15.5 394 |
18.8 475 |
18.8 475 |
|||
Liquid WithdrawalDevice P/N | N/A |
N/A |
N/A |
D050-8C00 |
N/A |
D050-8C00 |
D050-8C00 |
||||
Roller Base P/N |
N/A |
N/A |
N/A |
R018-8C00 | D024-8C02 | R033-8C00 | R033-8C00 |
Item# | |||
D004-9C11 | Cap, for 4LD Dewar | ||
D010-9C16 | Necktube Core, for LD10 | (lid) for LD10 Cryogenic Dewar | |
D024-8C02 | Roller Base, for Classic-25 | ||
D024-9C16 | Necktube Core, for Classic-25 | ||
D025-8C00 | Tipping Stand, for LD25 | ||
D025-9C16 | Necktube Core, for LD25 | ||
D050-8C00 | Liquid Withdrawal Device, | w/Hose Adapter, for LD Series | |
R018-8C50 | Dipper, for Liquid Nitrogen | ||
R033-8C00 | Roller Base for 35LD, 50LD, | 34XT, 34HC, 35HC, 35VCH & | LS750 Cryogenic containers |
12 Days of Holiday Cheer are here—unwrap amazing deals on lab supplies and equipment!
For a limited time, enjoy special pricing on overstock Celltreat Cryo Tubes and Globe Cryo Vials—perfect for your sample storage needs this holiday season!
Featured Overstock Products:
Celltreat Cryo Tubes (229925)
Globe Cryo Vials (GLB-CRYO-1ML and 3011)
Shop the featured overstock items now and take advantage of exclusive holiday pricing while supplies last!
Use promo code 12DAYSXMAS24
Special price applies only to the item specified. Other capacities or items cannot be substituted.
Innovation for the long-term protection of your precious samples.
You've spent days, months, even years getting your labor of love to this point . . . don't risk losing your precious samples to something as simple as a problematic o-ring!
Globe Scientific CryoClear™ vials feature an innovative polyethylene (PE) screw cap that is co-molded with a layer of thermoplastic elastomer (TPE). This special manufacturing process provides the leak-proof benefits required, while eliminating the risk of contamination and sample loss associated with the use of separate o-rings.
Store your samples with the utmost confidence using CryoClear™ cryogenic vials: the best and most leak-resistant cryogenic vials available for the long-term storage of samples at temperatures as low as -196°C.
- Lot certified to be human DNA free, RNase free, DNase free, pyrogen free and ATP free
- Non-pyrogenic, non-cytotoxic, non-mutagenic, heavy-metals free and BSE/TSE free
- Manufactured, assembled and packaged in an ISO 7 (Class 10,000) cleanroom
- Sterilized by beta radiation (SAL 10-6)
- Enhanced cap features a star socket designed specifically for use with automated capping/decapping equipment
- Slim profile cap design ensures better fit in racks and boxes
- Unique barcode printed on each vial for automated data collection
- White writing surface for specimen identification
- Printed graduations for accurate measurements
- Vials and caps are autoclavable
- Produced from medical grade raw materials that will not discolor after re-sterilization
- Tamper evident packaging
- Self-standing tubes interlock with Globe workstation racks
Temperatures generally range between -320°F (-196°C) at the liquid surface, and -299°F (-184°C) under the closed necktube core.
- Large Storage Capacity
- New Rugged Construction - ribbed high stregth aluminum body, magniformed necktube design, and more durable paint.
- Versatile storage system - convenient canister index location ring and internal spider
- Superior vacuum performance with super insulation provides maximum holding times.
- Security - optional low-level alarm is available for use with more valuable samples.
- Mobility - Roller bases are available for some models.
- Warranty: 2 years on vaccum, 1 year on electronic
Specifications
Model | HCL12 | HC20 | HC34 | HC35 | VHC35 |
Static holding time, days | 60 | 87 | 200 | 130 | 130 |
Evap. rate L/day | 0.2 | 0.23 | 0.17 | 0.27 | 0.27 |
LN2 capacity, Liters | 12 | 20 | 34 | 35 | 35 |
Weight empty Lbs | 21.6 | 26.4 | 35.4 | 39 | 37.9 |
Weight full, Lbs | 43 | 62 | 95.9 | 101.3 | 100.2 |
Neck diameter, inches | 3.6 | 3.6 | 3.6 | 4.7 | 4.7 |
Overall height, inches | 19 | 24.2 | 26.3 | 26.8 | 26.8 |
Overall diameter, inches | 15.6 | 15.6 | 18.8 | 18.8 | 18.8 |
Canister size | 5 inch | 11 inch | 11 inch | 11 inch | 11 inch |
Number of canisters | 6 | 6 | 6 | 10 | 6 |
Number of 2.0ml vials | - | 684 (6 per cane) | 684 (6 per cane) | 1020 (6 per cane) | 1260 (6 per cane) |
Item# | |||
R012-9C16 | Necktube Core, for HCL12 | ||
R018-8C00 | Roller Base for 25LD, 8XT, | 20XT, 12HCL, 20HC & 3K | Cryogenic containers |
R020-9C16 | Necktube Core, for HC20 | ||
R033-8C00 | Roller Base for 35LD, 50LD, | 34XT, 34HC, 35HC, 35VCH & | LS750 Cryogenic containers |
R034-8C15 | Cryo-Sentry Level Alarm, | for HC Series | |
R034-9C16 | Necktube Core, for HC34 | ||
R036-8C30 | Cryo-Sentry Level Alarm, | for LS750 and VHC35 | |
R036-9C16 | Necktube Core, for LS750 and | VHC35 | |
R036-9C24 | Canister, for VHC35 | ||
R036-9C27 | 7th Canister, for VHC35 | ||
R037-9C16 | Necktube Core, for HC35 |
LAB SERIES
High efficiency, very low LN2consumption
- LN2 storage in either liquid or vapor phase
- Near LN2 temperatures maintained at top of inventory storage system for overall sample viability
Single pivot point aluminum turntable design - smooth rotation and ergonomic use
- Eliminates any mechanical component maintenance
- Full height, segmented and labeled turntable provides easy inventory storage access and management Convenient access to measure LN2 level
Hinged lid and stainless-steel table top
- The lid includes locking capabilities and activates an automatic defog for quick viewing of inventory storage
- The table top provides a working surface and protection to electrical and plumbing components
Enhanced and intuitive controller technology
- Discrete thermistor level measurement and thermocouple temperature resolution within 0.1°C
- Capabilities for data collection, event scheduling and enhanced security settings
- Second access point for monitoring temperature
Ease of Use
- Integral folding step with slip-resistant surface, and mechanical lock for securing the step when stowed
- Flexible Fill Hose with 1.27 cm I.D. includes dual swivel connectors and a 3/8â male NPT adaptor included with purchase
CS Series Control System
Intuitive LN2 Control Technology
Control, monitor and secure your system with the CS Series Control
- Fully enclosed and protected battery back-up (optional) provides up to 72 hours of fully operational capability, including automatic LN2 filling.
- Solidly constructed enclosure with recessed display mount provides increased protection of electronics. The adjustable mounting post allows for greater viewing and operation.
- Communication center 12 VDC power, optional 12-volt battery back-up, remote alarm and three (3) communication channels are easily identified and accessible.
- Secured protective battery cover
MODELS |
20K |
38K |
40K |
80K |
94K |
|
External Operating Height |
in. |
42 |
44 |
42 |
42 |
40 |
Step Height |
in. |
11 |
11.5 |
11/16.3 |
11/17 |
11/22 |
Height |
in. |
53 |
56 |
53 |
53 |
62 |
Usable Height, Internal |
in. |
30 |
30 |
30 |
30 |
35.3 |
Outside Diameter |
in. |
34 |
42 |
45 |
59.5 |
59.5 |
Internal Working Diameter |
in. |
29.5 |
38 |
40.5 |
55 |
55 |
Neck Opening |
in. |
13 |
18 |
18 |
24.5 |
24.5 |
Capacity |
L. |
371 |
623 |
698 |
1269 |
1595 |
Weight, Empty |
lb. |
650 |
930 |
920 |
1550 |
1700 |
Maximum Gross Weight |
lb. |
1311 |
2040 |
2164 |
3811 |
4542 |
Inventory Control System |
||||||
No. 100/81 Cell Racks |
14 |
26 |
30 |
58 |
60 |
|
No. 25 Cell Racks |
4 |
12 |
8 |
12 |
8 |
|
Vial Capacity, 2 ml |
19500 |
37700 |
41600 |
79300 |
9300 |
|
Bag 25 ml (7 Level Rack) |
1624 |
2688 |
3108 |
5999 |
6856 |
|
Bag 50 ml (7 Level Rack) |
924 |
1582 |
1876 |
3381 |
3864 |
|
Bag 250 ml (5 Level Rack) |
500 |
900 |
990 |
1920 |
2304 |
|
Bag 500 ml (5 Level Rack) |
420 |
690 |
830 |
1610 |
1932 |
Features:
- New Rugged Construction - ribbed high stregth aluminum body, magniformed necktube design, and more durable paint.
- Versatile Storage System - convenient canister index ring and internal spider super vacuum performance with super insulation provides maximum holding times.
- Security - Accessory low-level alarm is available for more valuable samples
- Mobility - Roller bases are available
- Warranty: 2 years on vaccum, 1 year on electronic
Models |
XTL3 |
XTL8 |
XT10 |
XT20 |
XT34 |
|
Static Holding Time days (1) |
27 |
80 |
100 |
230 |
340 |
|
Working Time days (2) |
17 |
50 |
62 |
140 |
212 |
|
Evaporation Rate (1)liters/days |
0.11 |
0.10 |
0.10 |
0.09 |
0.10 |
|
Liquid Nitrogen Capacity- liters |
3 |
8 |
10 |
20.7 |
34 |
|
Weight Empty |
- lbs.-kg. |
7.2/3.3 |
19.6/8.9 |
16.5/7.5 |
26/11.8 |
34.75/15.8 |
Weight Full (3) |
- lbs.-kg. |
12.5/5.7 |
33.8/15.4 |
34.3/15.6 |
62.8/28.6 |
95.3/43.3 |
Neck Diameter |
- in. - mm. |
2.0/51 |
2.0/51 |
2.0/51 |
2.0/51 |
2.0/51 |
Overall Height |
- in. - mm. |
17.2/437 |
19/483 |
23.8/597 |
25.8/655 |
26.3/668 |
Overall Diameter |
- in. - mm. |
7.6/193 |
15.6/396 |
11.4/290 |
15.6/396 |
18.8/478 |
Number of Canisters |
|
6 |
6 |
6 |
6 |
6 |
Canister Dimensions (4) |
- in.-mm. |
1.5x5 38x127 |
1.5x5 38x127 |
1.5x11 38x279 |
1.5x11 38x279 |
1.5x11 38x279 |
Number of 1.2 ml & 2.0 ml vials (5/cane) |
NA |
NA |
150 |
150 |
150 |
|
Number of 1.2 ml & 2.0 ml vials (6/cane) |
NA |
NA |
180 |
180 |
180 |
|
Number of 1/2 cc straws (10/cane) |
NA |
NA |
540 |
540 |
540 |
|
Number of 1.2 cc straws -Bulk ( 1 level) |
750 |
750 |
750 |
750 |
750 |
|
Number of 1/2 cc straws -Bulk ( 2 levels) |
NA |
NA |
1500 |
1500 |
1500 |
|
Roller Base |
N/A |
R018-8C00 |
N/A |
R018-8C00 |
R033-8C00 |
|
Low-Level Alarm |
N/A |
N/A |
N/A |
R033-8C15 |
R033-8C15 |
Item# | |||
R003-9C16 | Necktube Core, XTL3 | ||
R003-9C24 | Canister, for XTL3 | ||
R008-9C24 | Canisters, for XTL8 | ||
R010-9C24 | Canister, for XT20 and XT34, | 5in. | |
R013-9C14 | Canister, for XT10, 11in. | ||
R013-9C16 | Necktube Core, for XT10 | ||
R018-8C00 | Roller Base for 25LD, 8XT, | 20XT, 12HCL, 20HC & 3K | Cryogenic containers |
R033-8C15 | Cryo-Sentry Level Alarm, | for XT Series | |
R033-9C16 | Necktube Core, for XT Series | ||
R033-9C24 | Canister, for XT20 and XT34, | 11in. |
SBS Format Cryogenic Tubes
- The vial body is made of medical-grade cryogenic polypropylene (PP) in line with USP Class-6 standards. The vial cap is made of high-density polyethylene (HDPE) which is recommended to be used in -196 liquid nitrogen phase.
- DNase/RNase free, non-endotoxin
- Autoclavable
- Electron beam sterilization, SAL = 10-6
The integrated injection-molded two-color vial body realizes multi-code tracking, which supports the traceability of samples and data sharing among multiple users, laboratories and automation, rendering warehousing and ex-warehousing of samples more convenient and faster and sample storage safer.
The product meets the SBS standard and provides an effective safety guarantee and management for biological sample libraries and other warehouses of various chemicals and biological products stored at low temperatures.
BioBucket™ is a general laboratory container that every lab could benefit from. Its collapsible nature makes it the ideal container for any lab looking to conserve storage space. BioBucket™ can be used as an ice bucket to keep samples cool over long periods of time, or as portable liquid container. The attached handle makes transportation a breeze while the molded base grip allows for easy pouring and cleaning. The BioBucket™ is perfect for field use as an environmental sample collection and transport receptacle.
Haier Biobank Series Liquid Nitrogen Container
It is suitable for the cryopreservation of plasma, cell tissues, and various biological samples in hospitals, laboratories, scientific research institutions, disease control and prevention centers, various biobanks, and other places.
Product Advantages
Easy to access
With the full opening design on the top of the product and hydraulic uncapping, it saves energy and is easier for storing and sample taking.
Brand-new intelligent monitoring system
It's equipped with an intelligent monitoring system and matched with an IoT module which can connect with Haier's big data cloud platform to realize the remote data transmission. Integrating three screens, it can realize the remote alarm via app, e-mail, and other ways.
Reduces frosting and freezing
The brand-new cover and interlayer exhaust structure can effectively minimize frost buildup at the exhaust port.
Key Design Features
High Degree of Safety
Double lock for double protection, ensures safer storage of samples.
The liquid nitrogen filter can effectively reduce impurities and prolong the service life of the whole machine.
When the external power supply is off, can still work with the battery power supply.
Ergonomic Design