Pre-cut Nitrocellulose membrane for Western blotting
Low-fluorescence Nitrocellulose membranes are available in both 0.45 μm and 0.22 μm pore sizes to accommodate larger and smaller proteins, respectively. We recommend using the .45 µm pore size for the most analytical blotting: protein, ssDNA, and RNA transfers.
Quantity: 10 membranes each
Pre-cut PVDF membranes for Western blotting applications
Ideal for chemiluminescent and colorimetric Western blotting. Pre-cut to save you time in the lab. These low-fluorescence PVDF membranes reduce background noise and nonspecific protein binding for improved sensitivity. Available in three different pre-cut sizes.
Quantity: 10 membranes per package
Low-fluorescence PVDF membranes reduce background noise for improved sensitivity. PVDF (polyvinylidene difluoride) membranes are commonly used for immunoblotting techniques, like Western blots. During the blotting process, samples are transferred from the protein gel onto a PVDF membrane by electroblotting. From there they can be used for protein sequencing.
Pre-cut blotting paper for Western blot transfer
Forget about measuring and cutting blotting paper to the size of your mini-gels. Use these pre-cut papers to assemble your transfer “sandwiches”. Pre-cut blotting papers save time and reduce waste for the easiest Western blotting workflow.
Qty: 60 sheets
Blotting papers are cut to completely cover the gels and membranes.
For 8x10cm gels: blotting papers available in 9x13cm
For 7x9cm gels: blotting papers available in 8x10cm
Pre-cut blotting papers save time and reduce waste for the easiest Western blotting workflow. Forget about measuring and cutting blotting paper to the size of your mini-gels! Use these pre-cut papers to assemble your transfer “sandwiches”.
Blotting papers come pre-cut to completely cover the gels and membranes.
Cytiva 3MM Chr paper is the world's most widely used blotting paper.
This acceptance and usage reflect the high quality, purity and consistency that are relied upon by researchers doing Southern, Northern and Western transfers. 3MM Chr paper is now available in the most widely used sizes. A medium thickness paper (0.34 mm) used extensively for blotting in electrophoresis for lifting of sequencing gels.
GB004 A thick gel blotting paper (1.0 mm), used for wicking purposes only. Provides higher absorbency and more consistent wicking than paper towels. Recommended for applications where fewer layers of gel blotting paper must still ensure a high capacity. Fewer layers of blotting paper reduce the risk of trapping air bubbles. Recommended for capillary blotting of nucleic acids.
GB005 An extra-thick (1.2 mm ), highly absorbent paper recommended for applications where fewer layers of blotting paper must siill ensure a high capacity. Recommended for semi-dry blotting of proteins.
17 Chr A thick (0.92 mm) and highly absorbent paper.
31 ET An extremely fast and thick paper (0.5 mm) with a fairly soft surface.
Features and Benefits
3MW is used widely in nucleic acid and protein research for blotting, wicking, spacers, and gel drying due to its purity, quality and consistent results. Uniform capillary action provides even wicking and enables gel transfers to be lifted RELIABLY from glass supports.
Protran nitrocellulose membranes are the most frequently specified transfer media in the world for a wide range of applications. Protran membranes are manufactured using 100% pure nitrocellulose to ensure the highest binding capacity possible. Other membranes referred to as "nitrocellulose" may actually contain large amounts of cellulose acetate, which will lower the protein binding capacity. In addition to high binding capacity, Protran nitrocellulose membranes inherently have very low background. The superior surface properties of the membrane guarantees superior signal-to-noise ratios, without the need for stringent washing conditions. Unlike PVDF membranes, Protran nitrocellulose requires no methanol pre-wetting step. This makes it the membrane of choice for proteins that prefer aqueous environments. Prior to transfer, the membrane is simply wet in water and then in the transfer buffer, with no other necessary pre-treatment steps. Protran membranes exhibit the best handling strangth of all pure nitrocellulose membranes. Features:
Grade
Pore Size
BA75
0.05µm
BA79
0.1µm
BA83
0.2µm
BA85
0.45µm
Nitrocellulose Membranes
Combining the advantages of high protein binding capacity with low background and high membrane stability, which ensures easy handling.
Ideal for western blotting, DNA blotting as well as dot or slot blots. They have been optimized for all protein blotting systems, such as electro transfer, semi-dry or simple capillary blotting
Specifications:
11306
11327
Dimensions
300 mm × 3 m
Flow rate
70 mL/min/cm²/bar (Water)
25 mL/min/cm²/bar (Water)
Pore size
0.45 µm
0.22 µm
Wettability
Hydrophilic
Packaging
Non-sterile, bulk packed
Pack Size
1
Color
White
Filter Type
Blotting Membranes
Filter Format
Reels
Bubble point
2.4 bar
4.2 bar
Burst pressure
0.2 bar
0.8 bar
Membrane thickness
130 µm
Filter Material
Cellulose Nitrate (CN)
Application
Blotting