|◀ 193 - 204 of 577 ▶|
View:
  • The CleanSpot is designed to fulfill a very important laboratory need...control of PCR contamination.
  • Just 25 - 30 minutes of UV irradiation in the CleanSpot can prevent unwanted PCR contamination.
  • The combination of a special light reflector and two powerful overhead UV bulbs generate Pyrimidine Dimers (T,C) and other photo defects in contaminating target sequences, thus eliminating falsely primed products that result in countless lost time and expense.
  • The CleanSpot is designed to prevent unwanted contaminant DNA in amplification mixtures, thereby saving many lost hours and expensive samples.
  • The UV resistant acrylic enclosure provides a contained, dead air space in which to set up your reactions and permits safe 254nm UV irradiation of solutions and supplies. This powerful UV wavelength renders DNA contaminants biologically inactive in 30 minutes or less.
  • The thick front panel is an effective beta irradiation shield as well as acting as a breath guard. An overhead fluorescent light illuminates the work area.
  • Dimensions: 18"L x 24"W x 28"H
  • 1 year warranty
Item#:
CS01
Your Price:
2984.00
Each
This item is discontinued


PR1MA Cod Uracil-DNA Glycosylase

 

PR1MA Cod Uracil-DNA Glycosylase (cUNG) is a recombinant, thermolabile enzyme that removes uracil from DNA. It is ideal for preventing carry over contamination during RNA or DNA amplification reactions that substitute dUTP for dTTP. cUNG is the only commercially available UNG that is completely and irreversibly inactivated by moderate heat treatment, unlike bacterial versions of the enzyme. Cod UNG treatment in combination with targeted pre-amplification using dUTP provides a simple and efficient solution to eliminate carry-over contamination and the generation of false positives and inaccurate quantification.

  • Optimal temperature: 37°C
  • Heat inactivation: 55°C for 5 minutes
  • Enables contamination control in PCR and other amplification methods
  • Does not degrade product after inactivation, enabling downstream use of the amplicon
  • Storage temperature: -20°C

Buffer composition

  • 50% glycerol
  • 50 mM Tris-HCl
  • 50 mM KCl
  • 1 mM DTT
  • 0.1  mM EDTA
  • 0.1% Tween-20
  • pH = 7.5

*These products are intended for research use only, not for therapeutic or diagnostic purposes in humans or animals. The safety and efficacy of these products in diagnostic or other clinical uses has not been established.
 

with 500 Color Coding Inserts

The Rotocycler 72 facilitates the handling and insertion of caps on the tubes by offering a special solid aluminum loading rack. This rack can hold up to 18 x 0.1 mL tube strips for a total of 72 tubes. Other cavities can hold larger reaction tubes. To keep reactions cool during setup, simply place the rack in a refrigerated area. For easy reference, all wells are numbered. Color coding is made possible by inserting a Capinsert in up to two locations on the rack.


Includes: Rotocycler 72 and 500 assorted color coding inserts


Accessories for the Rotocycler 72


T319-4N

Rotocycler 0.1 mL Tube and Cap Strips for Qiagen Rotor-Gene Q 
Real-Time Rotary Analyzer

T319-72D2

Rotocycler 72 Rotor with 100 µL wells for Qiagen Rotor-Gene Q 
Real-Time Rotary Analyzer

T319-100D1

Rotocycler 100 Rotor with 25 µL wells for Qiagen Rotor-Gene Q 
Real-Time Rotary Analyzer

Item#:
T319-4WS1
Your Price:
552.42
Each
Format, 24/cs, 100uL tubes for

The RotoCycler Discs are specially made to be used with the Qiagen Rotor-Gene Q Real-Time Rotary Analyzer. Two models are available: a 72-well format with 100 µL tubes and a 100-well format for reactions up to 25 µL. The discs a"one-piece "plate" equivalent, having vertically oriented wells compatible with automated reaction setup using a robotic liquid handling system.

Item#:
T319-72D2
Your Price:
233.19
Each
Item#:
ASTHINSEALSFI
1mL, 1 vial of 1000ul

Affordable price & shipped at room temperature.

 

A premixed, ready-to-use solution for efficient amplification of DNA templates by PCR.

  • 2X Eco-Taq MasterMix contains Taq DNA Polymerase, dNTPs, Mg2+ and Reaction Buffer at optimal concentrations for efficient amplification of DNA templates by PCR, as well as an inert loading dye.
  • This pre-mixed formulation saves time and reduces contamination due to the fewer pipetting steps required for PCR set up. To prepare the final PCR, only primers and template DNA need to be added.
  • The mix retains all features of Taq DNA Polymerase and can amplify DNA targets up to 5 kb (simple template).
  • The elongation velocity is 0.9~1.2kb/min (70~75°C).
  • It has 5' to 3' polymerase activity but lacks 3' to 5' exonuclease activity which results in a 3'-dA overhang PCR product.

 

Features:

  • Convenient: Just add primers and template DNA
  • High yields of PCR products with minimal optimization.
  • High efficiency: saves your time by simplifying the process
  • Reproducible: lower contamination risk and pipetting error.

    Applications:

  • High-throughput PCR.
  • Routine PCR with high reproducibility
  • Generation of PCR products for TA cloning

    Contents:
    2X Taq Mix 1ml

    Store at -20°C
    For research use only

Item#:
ECO-TAQ1
Your Price:
35.00
Each

MIDSCI ELISA & Short Term


The polyester films are a great general purpose seal; ideal for sample protection and elimination of well-to-well sample cross contamination. The acrylic adhesive offers a strong bond that seals tightly on polypropylene and polystyrene plates.

This seal is ideally suited for short term storage, Elisa assays, prevention of sample loss, and general lab usage.

The paper backing of this film is scored on both ends to allow for two handed (precise) placement on the plate.

For PCR applications see our standard PCR film or our Real Time PCR film.

For applications where accessing samples through the seal with pipet tips or a probe is required, see the pierceable aluminum (MID-PCR-200) film.

Certified free of RNase, DNase, Pyrogen, and nucleic-acid contamination.
 

Specifications: 

Length146.05 mm
Length (w/ end tabs removed)119.05 mm
Width79.38 mm
Overall Thickness3.1 mil
Adhesive Thickness1.1 mil
MaterialPolyester
AdhesiveMedical Grade Acrylic
Max. Temperature120 °C
Min. Temperature-40 °C
Primary UsagesElisa, Storage or Sample Cover
 
Item#:
ASMIDSCIELISA


This brand is being discontinued and will only be available while supplies last.
 
Need a great DNA Safe Stain at a great price? Try PR1MA!  Click here to order.

 

  • Safest DNA stain by far
  • Replaces EthBr in agarose gel electrophoresis
  • Detection of DNA and RNA
  • Excitation at 290nm & 490 nm
  • Emission at 530nm

DNA SafeStain is a new and safe nucleic acid stain for visualization of double-stranded DNA, single-stranded DNA, and RNA in agarose gels. The dyes are developed to replace toxic ethidium bromide (EthBr, a potent mutagen), commonly used in gel electrophoresis for visualization of nucleic acids in agarose gels. DNA SafeStain is non-carcinogenic by the Ames-test. The results are negative in both the mouse marrow chromophilous erthrocyte micronucleus and mouse spermary spermatocyte chromosomal aberration tests.

DNA SafeStain emits green fluorescence when bound to DNA. It has two excitation wavelength peaks when bound to nucleic acid, at 290nm and 490nm and the emission can be detected at 530nm.

Storage:
Store under dark at 4°C or room temperature.

User Instruction: 
DNA SafeStain can be used in the exact same way as EtBr in agarose gel electrophoresis. For example, add 100µl to 1 liter of 1X running buffer (1xTAE or 1x TBE), and use this DNA SafeStain containing buffer to make the agarose gel and run the gel.

 

Special Notes: 
1. For best results, dilute the DNA SafeStain 1:10,000 in your gel running buffer and use this dye-containing running buffer to make your agarose gel and to run the gel.

2. As is the case with EtBr; add more DNA SafeStain, if brighter DNA bands are desired. To view the results, any conventional DNA gel viewing light box or gel documentation system should work well with the DNA SafeStain; although, using a LED light instead of a UV light source is preferred due to the harmful nature of UV light.

This Product is For Research Use Only

For the proper disposal of this product, follow University or Company Guidelines.

 

Due to supply constraints 100-SEAL-PLT, STR-SEAL-PLT, XTR-100 and XTR-LG-100 are out of stock.


STR-SEAL-PLT alternative is GPS-PP-100.

PP-100 substrate is polypropylene instead of polyester for the STR-SEAL-PLT.  GPS-PP-100 is designed for the same application – ELISA/Incubation/General Storage.

100-SEAL-PLT alternative is TTS-100.

XTR-100 and XTR-LG-100 alternatives are XTR2-100 & XTR2-LG-100.
 

ELISA, Incubation, and Short Term Incubation Sealing Films

All films on this page are designed for ELISA, Incubation, and Short Term Incubation Sealing Films. If you are looking for something specific please consult our selection guides by attribute or application on this page. All films are certified DNase- & RNase-Free.

Specific film descriptions:

1x8 MiniStrips (GP-CS1X8-400 and GPS-CS1X8-400) are less expensive than full-size sheets when using only a partial plate. Designed for use with either 1x8 strip-well ELISA plates or standard 96-well plates where rows must be selectively protected or accessed. Ideal for COVID-19 testing to seal a row of 8 wells after swabs are deposited into a deep-well plate.

General Purpose (GP-PP-100 and GPS-PP-100) polypropylene lms oer superior barrier properties to minimize evaporation and prevent well-to-well contamination. Ideal for use with polypropylene plates.

Pre-scored lm (SP2-RL-500) on a roll is a more economical and ecient alternative to rapidly seal microplates or racked test tubes; faster than applying single sheeted lm. Self-standing, non-slip supports hold the pre-scored lm roll securely in place for quick and easy bench- top dispensement. The roll unwind tension can be easily adjusted to user preference. Continuous backing liner can be torn o or fed directly into a waste basket for disposal.

The SealMate SealPlate Starter Kit (SM-KIT-SP and replacement rolls) features a re-usable dispenser and two rolls of perforated lm. The dispenser facilitates the quick and easy dispensing of lm from a roll allowing microplates to be sealed three times faster than using sheeted lms. Cost-eective replacement rolls are sold separately. Ideal for use under the hood; the SealMate dispenser minimizes lm contamination.

SealPla te (100-SEAL-PLT and STR-SEAL-PLT) minimizes evaporation, prevents well-to-well contamination and spillage. Eliminates the edge eect which can occur with plate lids (e.g. greater evaporation in the outside plate wells).

SealPlate Color Tabs (SP-IDx-100) Each end-tab features a colored dot and white writing area. An inscribed color-coded end-tab can be removed and pasted into a laboratory notebook while the other remains on the plate for identication. The lm sheet can be removed from the plate without disturbing the identication label due to the nely perforated end-tabs. Choose from 5 dierent individual colors or the assortment pack.

SealPlate 2x8 MiniStrips (SP-2X8-50 and SPS-2X8-50) are less expensive than full-size sheets when using only a partial plate. Designed for use with either 1x8 strip- well ELISA plates or standard 96-well plates where rows must be selectively protected or accessed.

ValueSeal (SP-VS-100) features smaller dimensions and a single non-perforated end-tab to provide a more cost-eective alternative to protect samples from evaporation, external contamination, dust and particulates.

|◀ 193 - 204 of 577 ▶|