View:

The Benchtop Cryo-Station is a compact desktop workstation for snap-freezing samples in liquid nitrogen.


The CryoStation is used in conjunction with either the Cryo-Dipper or Cryo-Net, depending on what types of samples will be frozen.


Specifications:

    • Super-insulating triple density expanded polystyrene
    • Wall thickness: 51mm
    • Low thermal mass of EPS minimizes initial liquid nitrogen boil off
    • Lightweight construction
    • No glass liner to break
    • 2" thick lid eliminates condensation
    • Max volume: 1L
    • Working volume: 750mL
    • Opening Diameter: 89mm
    • Dimension: 280mm x 190mm
Item#:
CRST-1000
Your Price:
62.00
Each

The Cryo-Dipper is used in conjunction with the Cryo-Station for organized sample freezing, storage and retrieval.


Specifications:

  • Quickly load tubes for freezing
  • Easily retrieve tubes
  • Holds 36 externally threaded cryogenic vial, .5mL & 1.5/2.0 mL tubes
  • Movable weights prevent floating
  • Durable PVC construction
  • Dimensions: 178mm x 80mm (diameter)
  • Hole size: approximately 11mm
Item#:
CRDP-1000
Your Price:
157.50
Each

The Cryo-Net is used in conjunction with the Cryo-Station for bulk sample freezing and retrieval.


Specifications:

  • Ideal for quick sample freezing
  • Once frozen, remove all samples at once
  • Durable nylon mesh
  • Open design for unimpeded liquid nitrogen access
  • 5 bags per unit
Item#:
CNET-1000
Your Price:
30.00
Each

Classic Cryosystem Series

The Cryosystem Series combines the benefits of low nitrogen consumption with mid-range vial capacity to meet the diverse needs of today's professionals worldwide. The lightweight and low-space demands of these containers make them the most economical units in their class.

Features

  • Lockable lids
  • Low liquid nitrogen consumption
  • Lightweight aluminum construction
  • Easy access to store or retrieve samples
  • Square racks with boxes and dividers
  • 3-year vacuum warranty
  • Alarm Options:
    • LA-2B
    • BAT-1B

*CB202, CB402, and CB602: Roller base is not included
Item#:
ASCBS2002CRYOSYS

Value Added Cryosystem Series

The Cryosystem Series combines the benefits of low nitrogen consumption with mid-range vial capacity to meet the diverse needs of todays professionals worldwide. The lightweight and low-space demands of these containers make them the most economical units in their class.

Features:

  • Lockable lids
  • Low liquid nitrogen consumption
  • Lightweight aluminum construction
  • Easy access to store or retrieve samples
  • Square racks with boxes and dividers
  • 3 year vacuum warranty
  • Alarm Options: Built In
  • CRYO-LA
  • CRYO-BAT

  • *CB201, CB401, and CB601: Roller base is not included
    Item#:
    ASCBSVACYRO

    Standard LN2 Freezer

    Rely on liquid nitrogen to freeze your samples with a wide lab freezer from Custom BioGenic Systems. We stock the latest designs in laboratory freezers so that you can get your work done and stored. Lift open the wide lid to access the perfectly arranged racks. Space optimization is the goal with every ultra-low freezer. Simply pick the size that works for your application. Science and industry move ahead with the right tools in place.

    Each vessel is fully insulated with integrated alarms. Wide-lid LN2 freezers must meet the strictest of standards, and your research benefits with tight controls on temperature. Open the lid multiple times a day. The temperature won't budge from your preset position. Choose from our top six models in various sizes, including the S-90AB and S-5000AB. At Custom Biogenic Systems, we're pleased to assist you in finding the perfect storage system.

    Benefits to the Custom BioGenic Systems Standard Liquid Nitrogen Freezer:

    • Round, space saving design.
    • Stainless steel, vacuum insulated vessel.
    • Wide lid opening for easy access to all racks.
    • Ease of operation plus flexibility to operate vapor storage, immersion storage or a combination of both to store any type or size of sample.
    • Each unit includes a liquid level, auto-fill and alarm system to provide security.

    Accommodates:

    • Aluminum square racks
    • Stainless steel square racks
    • Vertical racks
    • Mini racks
    • Canister and frame systems
    • Vials
    • Boxes
    • Canisters / Cassettes
    • Platform dividers
    • Pie Racks
    • Pie Boxes
    Item#:
    ASCBSSTNLN2FREZ

    Custom BioGenic Systems Isothermal LN2 Freezers

    Isothermal LN2 freezers from Custom BioGenics offer cryogenic dry storage for medical laboratories, universities and research facilities while reducing the risk of cross-contamination. Our patented technology creates a jacketed space in the walls of the freezer, maximizing storage space inside and minimizing the chances of cross-contamination. The wide lid makes it easy to access samples without affecting the temperature inside the freezer.


    Cryogenic dry storage eliminates many of the risks associated with liquid nitrogen contact. User safety is of paramount importance in any laboratory setting, and dry storage is less risky for the user than coming into contact with liquid nitrogen. Cryogenic storage methods that rely on contact also subject the vials to shrinking and expansion, which lead to sudden explosion. Dry storage allows for consistent temperatures and more stable storage. All our vapor storage freezers accommodate standard rack systems and adhere to industry best practices for temperature uniformity.


    Custom BioGenic Systems Isothermal Liquid Nitrogen Freezers offer liquid nitrogen storage temperatures without liquid nitrogen contact. Liquid nitrogen is stored in our patented jacketed space in the wall of the freezer. This technology offers safe dry storage for your samples. With no liquid nitrogen in the storage area the risk of cross contamination and the safety risks associated with the handling of liquid nitrogen are greatly reduced. This also means that the entire storage space can be used for inventory. Our wide lid opening provides easy, unrestricted access to samples and wont affect the temperature inside the freezer. All Isothermal freezers use our time tested and reliable 2301 controller with a dual temperature display, autofill and many additional features. Custom BioGenic Isothermal Liquid Nitrogen Freezers have an industry best temperature gradient that averages -193°C inside the storage area.

    Features:

    • Store samples at liquid nitrogen temperature with no liquid nitrogen contact.
    • Same internal usable space as existing liquid nitrogen freezers (no lost storage space).
    • Greatly reduces possibility of samples cross contamination.
    • Comes standard with 2301 Auto-Fill / Monitoring System.
    • Accommodates all standard rack systems.
    • Added user safety eliminating contact or splashing of liquid nitrogen.
    • Increased interior visibility.
    • Minimal interior temperature gradient.
    • Round space saving design.
    • Stainless steel construction.
    • Castor mounted for easy mobility.
    • Advanced woven lid gasket design.
    • Counter balanced lockable lid.
    • Annular fill and sensor tubes.

    Accommodates:

    • Aluminum square racks
    • Stainless steel square racks
    • Vertical racks
    • Mini racks
    • Canister and frame systems
    • Vials
    • Boxes
    • Canisters / Cassettes
    • Platform dividers

    Why is dry storage important?

    • Dry storage greatly reduces the risk of cross contamination.
    • Added user safety by eliminating liquid nitrogen contact.
    • Utilize the entire storage space; no space lost to bulky platforms.
    • Liquid nitrogen temperatures with no liquid nitrogen contact.
    • Vapor circulation provides better visibility in the storage area.
    • Wide lid opening for easy access to all racks.
    • Accommodates all standard rack systems.
    • Industry best temperature uniformity.

    Safety
    Storage in liquid nitrogen can make vials shrink. This may cause liquid nitrogen to seep into the vials, which on re-warming, expand and subsequently explode as nitrogen vaporizes inside the vials. Dry storage eliminates this possibility. Also, the Isothermal design provides added user safety by eliminating contact with or splashing of liquid nitrogen.

    Cross Contamination
    Studies have shown that viral, bacterial and fungal pathogens can survive after suspension in liquid nitrogen. Infected samples can cross contaminate other samples in the same liquid nitrogen tank. Dry storage greatly reduces the possibility of cross contamination.

    Our 2301 controller is time tested, reliable and designed to keep your sample storage safe and secure.

    New 16 Port Connector:

    • 0-5 volt outputs provide temperature & level data for connection to existing alarm/monitor system.
    • 4-20 mA outputs provide temperature & level data for connection to existing alarm/monitor system.
    • Sequential and One-Fill-All-Fill input and output connection for filling systems.

    New two-level temperature display option:

    • Temp. A displays temperature at the lid, approximately 11"(27.94cm).
    • Temp. B displays temperature inside the storage space, approximately 20"(50.80cm)

    Additional Features:

    • Records 12 alarms & events such as fill start, fill stop, etc. with dated time stamp, printed or displayed.
    • Ethernet and auxiliary RS485 for future expansion.
    • Dedicated 24Vdc signal output to activate a third 24Vdc valve to control the LN2 supply.
    • Global Remote Alarm-Dry contact that switches during any alarm condition.
    • Date Log- Print or display Temp. A, Temp. B and level with date and time stamp.
    Item#:
    ASCBSISOLN2FREZ

    Isothermal Carousel LN2 Freezer

    Custom BioGenic Systems V3000-AB/C Isothermal Carousel Liquid Nitrogen Freezers offer liquid nitrogen storage temperatures without liquid nitrogen contact. Liquid nitrogen is stored in our patented jacketed space in the wall of the freezer. This technology offers safe dry storage for your samples. With no liquid nitrogen in the storage area the risk of cross contamination and the safety risks associated with the handling of liquid nitrogen are greatly reduced. Our built-in carousel can be safely rotated with an external handle, there is no need to reach inside the freezer and our square lid opening won't restrict access to square racks. All Isothermal Carousel freezers use our time tested and reliable 2301 controller with a dual temperature display, autofill and many additional features. Custom BioGenic Isothermal Carousel Liquid Nitrogen Freezers have an industry best temperature gradient that averages -193°C inside the storage area.

    Features:

    • No need to remove one rack to access another
    • No unnecessary exposure to room temperatures
    • Carousel is rotate from outside of the freezer reducing the risk of injury or temperature fluctuations
    • Exceptional temperature uniformity
    • Easy access to samples from the front of the freezer
    • Removable console allows for complete access to the sample storage space if necessary
    • CBS Isothermal Carousel Freezers are cooled by a patented liquid nitrogen jacket, with no liquid in the sample storage space
    • The only true dry storage freezer available
    • No risk of cross-contamination though liquid nitrogen contact without the need for special packaging
    • The isothermal design also provides added user-safety eliminating contact with or splashing of liquid nitrogen.

    Accommodates:

    • Aluminum square racks
    • Stainless steel square racks
    • Vertical racks
    • Mini racks
    • Canister and frame systems
    • Vials
    • Boxes
    • Canisters / Cassettes
    • Platform dividers

     

    Our 2301 controller is time tested, reliable and designed to keep your sample storage safe and secure.

    New 16 Port Connector:

    • 0-5 volt outputs provide temperature & level data for connection to existing alarm/monitor system.
    • 4-20 mA outputs provide temperatur & level data for connection to existing alarm/monitor system.
    • Sequential and One-Fill-All-Fill input and output connection for filling systems.

    New two level temperature display option:

    • Temp. A displays temperature at the lid, approximately 11" (27.94 cm).
    • Temp. B displays temperature inside the storage space, approximately 20" (50.80 cm)

    Additional Features:

    • Records 12 alarms & events such as fill start, fill stop, etc. with dated time stamp, printed or displayed.
    • Download cryomonitor data files to PC and convert them .csv files for use in Microsoft Excel.
    • Ethernet and auxiliary RS485 for future expansion.
    • Dedicated 24Vdc signal output to activate a third 24Vdc valve to control the LN2 supply.
    • Global Remote Alarm-Dry contact that switches during any alarm condition.
    • Date Log- Print or display Temp. A, Temp. B and level with date and time stamp.
    Item#:
    ASISOTHERMCAR1

    Store and transport low-temperature liquid gases or high temperature liquids. Dewar flasks are available in two sizes: 1000ml or 500ml and come complete with vented stainless steel lids. Model SDF-1000 comes with removable stainless steel handle.

    Specifications:


    Part Number

    Capacity

    OD

    ID

    H

    D

    SDF-500

    500mL

    86 mm/3.4 in

    65 mm/2.56 in

    203 mm/7.99 in

    182 mm/7.17 in

    SDF-1000

    1000mL

    122 mm/ 4.8 in

    100 mm/3.93 in

    177 mm/ 6.97 in

    157 mm/6.18 in

    Item#:
    ASLN2LDDEWARSSS

    Cryo Express (CX) are designed to safely transport a wide variety of materials at cryogenic temperatures. The unique absorbent material prevents a liquid spill if the unit is tipped over. Storage temperature inside the shipping cavity remains at approximately 150° C until the liquid nitrogen evaporates from the absorbent material. 
    Features:

    • Advanced Concept Absorbent enables faster charging.
    • Complies with IATA regulation
    • New rugged construction includes dependable, stronger, magniformed necktube design, ribbed high strength aluminum body, and more durable paint system.
    • Superior vacuum performance with super insulation provides maximum holding times.
    • Optional storage accessories include a five shelf rack system for the CX500
    • Lockable lids.
    • Warranty: 2 years on vacuum, 1 year on electronic

    Models

    CX100

    CXR100

    CXR500

    Static Holding Time days(1)

    24

    16

    11

    Working Time days(2)

    17

    11

    7

    Evaporation Rate(1)liters/days

    0.18

    0.23

    0.60

    Liquid Nitrogen Adsorbed  liters

    4.4

    3.7

    6.7

    Weight Empty

    lbs.kg.

    11.7 5.3

    11.7 5.3

    30 13.6

    Weight Full(3)

    lbs.kg.

    19.5 8.9

    18.3 8.3

    43.7 19.8

    Neck Diameter

    in. mm.

    2.78 71

    3.58 91

    8.5 216

    Overall Height

    in. mm.

    18.4 467

    19.4 493

    26.9 683

    Overall Diameter

    in. mm.

    9.2 234

    234 9.2

    15.5 391

    Number of Canisters

     

    1

    1

    N/A

    Canister Dimensions

     in.mm.

    2.64x11.0 67x279

    2.64x11.0 67x279

    N/A N/A

    Number of 1.2 ml & 2.0 mlvials (5/cane)(4)

    85

    85

    500

    Number of 1.2 ml & 2.0 ml vials (6/cane)(4)

    102

    102

    500

    Number of 1/2 straws (10/cane)

    280

    280

    N/A

    Number of 1/2 cc straws Bulk ( 1 level)

    490

    490

    N/A

    Number of 1/2 cc straws Bulk ( 2 levels)

    980

    980

    N/A

    Padded carton

    37019277

    N/A

     

    Item#
    CP70-9C18 Necktube Core, for CX500 or CXR500
    CP70-9C44 Rack, for Blood Bag, for CX500
    CXR100-9C01 Necktube Core, for CXR100
    CXR100-9C24 Canister, for CXR100
    CXR100-9C30 Replacement Adsorbent Set, for CXR100 or CXR500
    CX10-8C00 Shipping Case, for CX100
    RS30-9C44 Rack, 5 Shelf, for CXR500, No Boxes
    R005-9C21 Necktube Core, for CX100
    R005-9C24 Canister, for CX100
    R24K-9C44 Polycarb Boxes, 100 Cells, 24/cs
    3701-9277 Shipping Case, for CX100 Lightweight padded carton
    Item#:
    ASLN2CXCXR
    The Extended Time Series (XT) of cryogenic refrigerators are designed for long-term storage of a variety of materials at cryogenic temperatures. This series also offers a low profile model (XTL) for use in more confined workspaces.

    Features:

    • New Rugged Construction - ribbed high stregth aluminum body, magniformed necktube design, and more durable paint.
    • Versatile Storage System - convenient canister index ring and internal spider super vacuum performance with super insulation provides maximum holding times.
    • Security - Accessory low-level alarm is available for more valuable samples
    • Mobility - Roller bases are available

    • Warranty: 2 years on vaccum, 1 year on electronic

    Models

    XTL3

    XTL8

    XT10

    XT20

    XT34

    Static Holding Time days (1)

    27

    80

    100

    230

    340

    Working Time days (2)

    17

    50

    62

    140

    212

    Evaporation Rate (1)liters/days

    0.11

    0.10

    0.10

    0.09

    0.10

    Liquid Nitrogen Capacity- liters

    3

    8

    10

    20.7

    34

    Weight Empty

    - lbs.-kg.

    7.2/3.3

    19.6/8.9

    16.5/7.5

    26/11.8

    34.75/15.8

    Weight Full (3)

    - lbs.-kg.

    12.5/5.7

    33.8/15.4

    34.3/15.6

    62.8/28.6

    95.3/43.3

    Neck Diameter

    - in. - mm.

    2.0/51

    2.0/51

    2.0/51

    2.0/51

    2.0/51

    Overall Height

    - in. - mm.

    17.2/437

    19/483

    23.8/597

    25.8/655

    26.3/668

    Overall Diameter

    - in. - mm.

    7.6/193

    15.6/396

    11.4/290

    15.6/396

    18.8/478

    Number of Canisters

     

    6

    6

    6

    6

    6

    Canister Dimensions (4)

    - in.-mm.

    1.5x5 38x127

    1.5x5 38x127

    1.5x11 38x279

    1.5x11 38x279

    1.5x11 38x279

    Number of 1.2 ml & 2.0 ml vials (5/cane)

    NA

    NA

    150

    150

    150

    Number of 1.2 ml & 2.0 ml vials (6/cane)

    NA

    NA

    180

    180

    180

    Number of 1/2 cc straws (10/cane)

    NA

    NA

    540

    540

    540

    Number of 1.2 cc straws -Bulk ( 1 level)

    750

    750

    750

    750

    750

    Number of 1/2 cc straws -Bulk ( 2 levels)

    NA

    NA

    1500

    1500

    1500

    Roller Base

    N/A

    R018-8C00

    N/A

    R018-8C00

    R033-8C00

    Low-Level Alarm

    N/A

    N/A

    N/A

    R033-8C15

    R033-8C15

     

    Item#
    R003-9C16 Necktube Core, XTL3
    R003-9C24 Canister, for XTL3
    R008-9C24 Canisters, for XTL8
    R010-9C24 Canister, for XT20 and XT34, 5in.
    R013-9C14 Canister, for XT10, 11in.
    R013-9C16 Necktube Core, for XT10
    R018-8C00 Roller Base for 25LD, 8XT, 20XT, 12HCL, 20HC & 3K Cryogenic containers
    R033-8C15 Cryo-Sentry Level Alarm, for XT Series
    R033-9C16 Necktube Core, for XT Series
    R033-9C24 Canister, for XT20 and XT34, 11in.
    Item#:
    ASLN2XTSER

    LD Series

    The LD Series of cryogenic dewars are designed for storing and dispensing small amounts of liquid nitrogen. The series includes a beaker style dewar with a wide mouth (LD5) and pitcher-style model for easy pouring (LD4).

    Features

      High performance modern construction and advanced insulation materials assure high thermal efficiency

      New rugged construction, ribbed high strength aluminum body, magniformed necktube design, and more durable paint system

      Easy operation lightweight snap-on cap and necktube assures tight closure and easy access, convenient 
    larger handles

      Superior vacuum performance with super insulation provides maximum holding times

      Optional equipment includes liquid withdrawal device, tipping stand, dippers and roller base (for some models)

    Warranty: 2 years on vaccum, 1 year on electronic

    Models

    LD4

    LD5

    LD10

    LD25

    Classic 25

    LD35

    LD50

    Static Holding Time days(1)

    10

    6

    45

    109

    119

    152

    122

    Working Time days(2)

    N/A

    N/A

    N/A

    N/A

    N/A

    N/A

    N/A

    Evaporation Rate(1)liters/days

    0.40

    0.77

    0.22

    0.23

    0.21

    0.23

    0.41

    Liquid Nitrogen Capacity - liters

    4

    5

    10

    25

    25

    35

    50

    Weight Empty

    - lbs.-kg.

    6.6 3.0

    6.9 3.1

    14.5 6.6

    23.2 10.5

    19 8.6

    35.1 16.0

    38.7 17.6

    Weight Full

    - lbs. - kg.

    13.7 6.2

    15.8 7.2

    32.3 14.7

    67.7 30.8

    63.5 28.9

    97.4 44.3

    127.7 58.0

    NeckDiameter

    - in. - mm.

    1.2 30

    5.6 142

    2.0 51

    2.5 64

    2.0 51

    2.5 64

    2.5 64

    Overall Height

    - in. - mm.

    17.0 432

    17.5 445

    23.5 597

    25.8 655

    22.9 582

    26.3 668

    32.4 823

    OverallDiameter

    - in. - mm.

    7.6 193

    7.6 193

    11.4 290

    15.6 396

    15.5 394

    18.8 475

    18.8 475

    Liquid WithdrawalDevice P/N

    N/A

    N/A

    N/A

    D050-8C00

    N/A

    D050-8C00

    D050-8C00

    Roller Base P/N

    N/A
    N/A
    N/A
    R018-8C00 D024-8C02 R033-8C00 R033-8C00

     

    Item#
    D004-9C11 Cap, for 4LD Dewar
    D010-9C16 Necktube Core, for LD10 (lid) for LD10 Cryogenic Dewar
    D024-8C02 Roller Base, for Classic-25
    D024-9C16 Necktube Core, for Classic-25
    D025-8C00 Tipping Stand, for LD25
    D025-9C16 Necktube Core, for LD25
    D050-8C00 Liquid Withdrawal Device, w/Hose Adapter, for LD Series
    R018-8C50 Dipper, for Liquid Nitrogen
    R033-8C00 Roller Base for 35LD, 50LD, 34XT, 34HC, 35HC, 35VCH & LS750 Cryogenic containers
    Item#:
    ASLN2LDDEWARS
    View: