Home  >  Equipment  >  Incubators and Ovens  >  Ovens  > Shel Lab Vacuum Oven

Shel Lab Vacuum Oven

Item #: ASVACOVEN 

2 year limited warranty

 
SVAC1
SVAC2
SVAC4
EXTERIOR DIMENSIONS (W × D × H)
17.5 × 22.8 × 23.5/(445 mm × 580 mm × 597 mm)
20.5 × 29.5 × 26.3/(521 mm × 750 mm × 667 mm)
26.5 × 34.5 × 32.3/(673 mm × 876 mm × 819 mm)
INTERIOR DIMENSIONS (W × D × H)
9 × 12 × 9/(228 mm × 304 mm × 228 mm)
12 × 20 × 12/ (304 mm × 508 mm × 304 mm)
18 × 24 × 18/(457 mm × 610 mm × 457 mm)
VOLUME
0.56 cu.ft. (15.9 L)
1.67 cu.ft. (47.2 L)
4.5 cu.ft. (127.4 L)
SHELF DIMENSIONS (W × D)
8.75 × 11 (222 mm × 280 mm)
11.3 × 19.0 (287 mm × 483 mm)
17.2 × 22.9 (437 mm × 582 mm)
UNIT WEIGHT
105 lbs (48 kg)
179 lbs (81 kg)
360 lbs (163 kg)
INTERIOR METAL
300 SST
300 SST
300 SST
EXTERIOR METAL
Painted Cold Roll Steel
Painted Cold Roll Steel
Painted Cold Roll Steel
OPERATING TEMPERATURE RANGE
Amb +10C - 220C
Amb +10C - 220C
Amb +10C - 220C
TEMPERATURE UNIFORMITY - MIDRANGE
6% of SP °C
6% of SP °C
6% of SP °C
TEMPERATURE STABILITY - MIDRANGE
0.1 °C
0.2 °C
0.25 °C
CONTROLLER TYPE
Digital
Digital
Digital
DISPLAY RESOLUTION
0.1 °C
0.1 °C
0.1 °C
POWER VOLTAGE , FREQUENCY AND CURRENT
110-120 VAC, 50/60 Hz, 7.0 Amps
110-120 VAC, 50/60 Hz, 10.0 Amps
110-120 VAC, 50/60 Hz, 13.0 Amps
MAX HVAC LOAD
2497 BTUs/hr
3766 BTUs/hr
4749 BTUs/hr
SAFETY CERTIFICATIONS
UL 61010-1, EN 61010-1, CSA 61010-1, CE
UL 61010-1, EN 61010-1, CSA 61010-1, CE
UL 61010-1, EN 61010-1, CSA 61010-1, CE
Gel/PCR DNA Fragment Extr

Efficient Gel Extraction and PCR Clean-up

The Gel/PCR DNA Fragments Extraction Kits are designed to recover or concentrate DNA fragments (50bp-10kb) from agarose gel, PCR reaction, or any other enzymatic reaction. This method uses a chaotropic salt and guanidine thiocyanate to dissolve the agarose gel and denature the enzymes. The DNA fragments in the chaotropic salt are bound to the glass-fiber matrix of the spin column. After washing off the contaminants, the purified DNA fragments are eluted by low salt elution buffer or water. Salts, enzymes, and unincorporated nucleotides can be effectively removed from the reaction mixture without phenol extraction or alcohol precipitation.

Sample:
up to 300mg agarose gel slice
up to 100µl PCR product or other enzymatic reaction
Format:
Spin columns
Operation:
Centrifuge/Vacuum Manifold
Binding Capacity:
10µg DNA
Expectant Yield:
80-90% for gel extraction
90-95% for PCR clean-up
Operational Time: 15min. for PCR clean-up/20min. for gel extraction
Applications:
PCR, Fluorescent or Radioactive Sequencing, Restriction Digests, DNA Labeling, Ligations

PNRNADNA

Isolation type
DNA
Source Cell
Gel
SKU Number Type Operating Temp Vol Price Quantity Add to Cart
SVAC1 Vacuum Oven 10°C above ambient to 220°C 0.6 Cu Ft
6326.00
Each
SVAC2 Vacuum Oven 10°C above ambient to 220°C 1.7 Cu Ft
8131.00
Each
SVAC4 Vacuum Oven 10°C above ambient to 220°C 4.5 cu ft
15523.00
Each
Vacuum Oven
Shel Lab Vacuum Oven
Special Order
Quantity: