STAT FAX 3300 Biochemistry Analyzer
Stat Fax® 3300 is designed for the processing of biochemistries, tube method immune assays, and drug assays from human serum, plasma, or urine. A removable flowcell installs in the read well to provide extremely rapid fluid sampling with low carryover. A builtin vacuum pump and an external waste bottle with level sensing are supplied standard. When the Flowcell is removed, the instrument accepts standard 12 mm round tubes as well as 1 cm square cuvettes. The design of the instrument includes many features to minimize operator error, such as stable factory calibration, automatic zeroing, complete operator prompting, detailed labeling, pre-programmed calculations, visual and audible
feedback, flags and error messages, minimal maintenance requirements. Test parameters, and standard curves are stored in memory for later recall. The Stat Fax® 3300 will store up to 120 tests in memory to be recalled for later use and allows for creation of Levey-Jennings plots for QC. In addition, it will store 512 Patient Results, 512 Control Results, 20 Patients on Worklist, and 15 tests per patient.
Â
SPECIFICATIONS: |
|
Photometric |
|
Linear Measurement Range: |
0.0 to 3.5 (flow-cell mode) |
 |
|
Photometric Accuracy: |
+/- (1% +/- 0.010) 0.0 through 1.5 ABS |
+/- (2% +/- 0.010) 1.5 through 3.0 ABS |
|
 |
 |
Stability: |
Drift of no more than 0.005A in 8 |
hours/bichromatic |
|
 |
 |
Light Source: |
Tungsten Halogen, 10 Watt, with |
automatic lamp saver |
|
 |
 |
Standard Wavelengths: |
340, 405, 505, 545, 580, and 630nm |
alternate filters available from 330 to |
|
750nm; an eight position filter wheel is optional |
|
 |
 |
Filter Type: |
IAD hardcoat interference, 10nm half |
Bandpass |
|
 |
 |
Tube Size: |
12mm round is standard |
 |
 |
Minimum Sample Volume: |
1mL for 12mm round tube |
250uL for flowcell |
|
 |
 |
Display: |
240x128 Graphic LCD w/ Backlight |
 |
 |
Printer: |
Thermal dot matrix with graphic capability |
Power Requirements: |
Auto-Switching Power Supply |
 |
 |
Voltage source: |
90 – 264 VAC |
 |
 |
Certifications: |
CE |
 |
 |
Speed: |
Reads, calculates and prints results, 3 |
seconds per tube |
|
 |
 |
Calculation Modes: |
Factor, Single Standard, Point-to-Point, |
Regression, Index Mode |
|
 |
 |
Test Storage: |
Stores 120 tests. Stores all parameters |
including wavelengths, calculations, unit |
|
codes, linear and normal ranges rate |
|
timing, standard values, test names, and |
|
previous standard curve. |
|
 |
 |
Dimensions: |
40cm (L) x 37 cm (W) x 14 cm (H) lid |
closed (30 cm lid opened), 14 lbs (6.4 kg) |
PNPLATEREAD

SKU Number | Size | Color | Qty | Skirt | # of Wells | Price | Quantity | Add to Cart |
PR-PCR2196F | 0.1 mL Fast Type | Natural A1 Cut | 10 Plates | Semi-Skirted | 96 |
25.18
Each
|
||
PR-PCR2196F-W | 0.1 mL Fast Type | White A1 Cut | 10 Plates | Semi-Skirted | 96 |
30.74
Each
|
||
PR-PCR2196LC | 0.1 mL LightCycler Type | Natural H12 Cut | 10 Plates | Semi-Skirted | 96 |
25.18
Each
|
||
PR-PCR2196LC-W | 0.1 mL LightCycler Type | White H12 Cut | 10 Plates | Semi-Skirted | 96 |
30.74
Each
|
||
PR-PCR2296 | 0.2 mL ABI Type | Natural A12 Cut | 10 Plates | Semi-Skirted | 96 |
30.30
Each
|
||
PR-PCR2296R | 0.2 mL ABI Type Raised Rim | Natural A12 Cut | 10 Plates | Semi-Skirted | 96 |
25.18
Each
|
||
PR-PCR2296S | 0.2 mL Straight Side | Natural A12 Cut | 10 Plates | Semi-Skirted | 96 |
25.18
Each
|
||
PR-PCR2296S-W | 0.2 mL Straight Side | White A12 Cut | 10 Plates | Semi-Skirted | 96 |
30.74
Each
|
||
PR-PCR2296-RB | 0.2 mL ABI Type | Assorted Colors A12 Cut | 10 Plates | Semi-Skirted | 96 |
29.09
Each
|
||
PR-PCR2296-W | 0.2 mL ABI Type | White A12 Cut | 10 Plates | Semi-Skirted | 96 |
30.74
Each
|