Home  >  Equipment  >  Microplate Readers and Washers  >  Microplate Readers  > SmartReader™ MultiMode Plate Reader

SmartReader™ MultiMode Plate Reader

Item #: ASMARTREADERMULPR 
Model Accuris SmartReader Multimode
Measurement Technologies Absorbance, Fluorescence, Luminescence
Plate Formats 6- to 384-well plates
Shaking Linear (4.7 Hz, 7.0 Hz, 13.5 Hz), orbital,
and double orbital (240 – 1200 rpm)
Incubation Range RT +4 °C to 45 °C
Display 10.0 inch touchscreen
Communication Ports 2 USB A type ports / 1 USB B type port
1 Ethernet port
RS232 interface
Dimensions (WxDxH) 42.0 x 55.0 x 38.6 cm
(16.5 x 21.7 x 15.2 in.)
Power Input AC 100 to 240 V, 50 to 60 Hz
Weight 33 kg / 72.8 lbs
Absorbance  
Light Source High Energy Xenon Flash Lamp
Detector Photodiode
Wavelength Accuracy 2 nm
Wavelength Repeatability 0.2 nm
Bandwidth (FWHM) > 2.5 nm
Wavelength Range 200 – 1000 nm, 1nm steps
Absorbance 0.0 – 4.0 OD
Resolution 0.0001 OD
Accuracy 96-precision mode:± (1.0 %+0.003Abs) @
(0.0-2.0Abs]± 2.0 % @ (2.0-3.0Abs]
Repeatibility CV < 1.0 % or
SD< 0.003 Fast(0.0-3.0Abs]CV < 0.5 %
or SD< 0.003 Accurate(0.0-3.0Abs]
Stray Light 0.1 % @ 220 nm
Linearity R2 > 0.999 @ [0.0-3.0Abs]
Measurement Speed < 15 seconds
Fluorescence  
Reading Mode Top Reading
Excitation Light Source High Energy Xenon Flash Lamp
Detector Photo Multiplier Tube (PMT)
Detection Limit ≤ 1 pM
Wavelength Range EX: 200 – 1000 nm; EM: 270 – 850 nm
Included Filter Cartridges (EX / EM): 470 / 525nm; 523 / 564nm;
                   624 / 692nm
Linear Dynamic Range 6 logs
Luminescence  
Detector Photo Multiplier Tube (PMT)
Detection Limit 15 amol / well
Linear Dynamic Range 6 logs
BCECF AM
ION Biosciences BCECF AM

BCECF AM is the most popular green fluorescent, intracellular pH indicator. BCECF has a pKa of ~7, and exhibits pH-dependent, dual-excitation properties (Ex/Em 430nm/535nm and 490nm/535nm) for ratiometric analysis. Ratiometry is optimal for imaging applications, and reduces effects of photobleaching, heterogenous dye loading, and variable cell morphology. For HTS applications, BCECF can also be used in non-ratiometric mode using standard fluorescein excitation and emission settings.
SKU Number Type # of filters Price Quantity Add to Cart
MR9620 SmartReader MultiMode Plate Reader, 115V (EX / EM): 470 / 525nm; 523 / 564nm; 624 / 692nm
24240.00
Each
MR9620-E SmartReader MultiMode Plate Reader, 230V (EX / EM): 470 / 525nm; 523 / 564nm; 624 / 692nm
24240.00
Each
MR9620-AIM Automatic Injection Module for MR9620 N/A
10500.00
Each
MR9610-SDP SmartDrop Accessory Plate for MR9610 N/A
3700.00
Each
MR9620-PC SmartReader PC Software (Research Version) N/A
424.20
Each
MR9620-CFR SmartReader PC Security Software (21 CFR Part 11 N/A
2020.00
Each
MR9620
SmartReader™ MultiMode Plate Reader
Special Order
Quantity: