Home  >  PCR, Protein, RNA, DNA  >  PCR  >  Equipment  >  qPCR Thermal Cyclers  > Azure Biosystems Cielo qPCR System

Azure Biosystems Cielo qPCR System

Limited Time Promo!
Item #: ASCIELO 

1 year standard warranty reflects the robustness and reliability of the system, giving you confidence in your results.

Azure Biosystems Cielo qPCR System
     
Dyes/Probes
Cielo 3
Cielo 6
SYBR Green, EvaGreen, FAM
X
X
VIC®, HEX, JOE, CAL Fluor® 540, CAL Fluor® Orange 560
X
X
TAMRA
 
X
ROX, TEX®615, CAL Fluor® Red 610
 
X
Cy®5, Quasar®670, Liz®, Mustang Purple®
X
X
C®y5.5
 
X
 
 
 
 
Cielo 3
Cielo 6
Part #
AIQ030
AIQ060
Product description
96-well Real-Time PCR instrument with 10.2” touchscreen interface,
3 dye channel filters
96-well Real-Time PCR instrument with 10.2” touchscreen interface,
6 dye channel filters
Sample capacity (wells)
96
96
Reaction volume
10–150µL
10–150µL
Excitation source
LED
LED
Detection channels
3
6
Multiplexing
Up to 3 targets
Up to 6 targets
Thermal element
Peltier
Peltier
Max. block ramp rate
6°C/sec
6°C/sec
Avg. sample ramp rate
4°C/sec
4°C/sec
Temperature uniformity
±0.2°C
±0.2°C
Temperature accuracy
±0.1°C
±0.1°C
Custom dye/chemistry
x
x
Chemistry capability
Fast/Standard
Fast/Standard
Detection sensitivity
1 Copy
1 Copy
Sensitivity
Detect differences as small as 2-fold in target quantities
in singleplex reactions
Detect differences as small as 2-fold in target quantities in singleplex reactions
Connectivity
USB, Wi-Fi, Ethernet
USB, Wi-Fi, Ethernet

 


Azure Cielo 3 AIQ030

Azure Cielo 6 AIQ060

Dyes/Probes

SYBR™ Green, EvaGreen™, FAM™

x

x

VIC®, HEX™, JOE™, CAL Fluor® 540, CAL Fluor® Orange 560

x

x

TAMRA™

 

x

ROX™, TEX®615, CAL Fluor® Red 610

 

x

Cy®5, Quasar®670, Liz®, Mustang Purple®

x

x

Cy®5.5

 

x

Other dyes/probes are possible depending on the system configuration.

 

T4 DNA Ligase

T4 DNA Ligase

Intact Genomics T4 DNA Ligase catalyzes the formation of a phosphodiester bond between juxtaposed 5'-phosphate and 3'-hydroxyl termini in duplex DNA or RNA.  This enzyme joins DNA fragments with either cohesive or blunt termini as well as repair single stranded nicks in duplex DNA, RNA or DNA/RNA hybrids.
 

Quality Control 
Quality control is performed following the production of each new lot of product to ensure that it meets the quality standards and specifications designated for the product. Each lot is repeatedly compared side-by-side with leading competitors to ensure our products outperform the competitor before product launching. 

Intact Genomics T4 DNA Ligase displays up to 3-5X higher ligation efficiency than the nearest competitor.

Product Source
E. coli strain expressing a recombinant clone

Quality Control 
Quality control is performed following the production of each new lot of product to ensure that it meets the quality standards and specifications designated for the product. Each lot is repeatedly compared side-by-side with leading competitors to ensure our products outperform the competitor before product launching. 

Contents & Storage

  1. T4 DNA Ligase
  2. 10x T4 DNA Ligase Reaction Buffer (w/o ATP)
  3. 10 mM ATP

Store all contents at -20 °C.

Storage Buffer 
50 mM Tris-HCl, 50 mM KCl, 1 mM DTT, 0.1 mM EDTA, 50% Glycerol, pH 7.5 @ 25 °C

10x T4 DNA Ligase Reaction Buffer (w/o ATP) 
500 mM Tris-HCl, 100 mM MgCl, 100  mM DTT, pH 7.5 @ 25 °C

Note
10x T4 DNA ligase buffer does not contain ATP. You need to add ATP separately.

Unit Definition 
One Weiss unit is defined as the amount of enzyme required to convert 1 nmol of 32P from pyrophosphate into Norit-absorbance material in 20 minutes under standard assay conditions.

Protocol

  1. Set up reaction buffer in a microcentrifuge tube on ice. Use a molar ratio of 1:3 vector to insert DNA.

  


Component

10 µl Reaction

Vector DNA

x µl

Insert DNA

x µl

10 mM ATP

1.0µl

10x T4 Ligase Buffer

1.0µl

T4 DNA Ligase

1.0µl

Add H2O up to

10.0µl

  

  1. Gently mix the reaction and centrifuge briefly.
  2. For cohesive ends, incubate 16 °C for overnight or at room temperature for 30 min.
  3. For blunt ends, incubate 16 °C for overnight or at room temperature for 2 hrs.
  4. Heat inactivate at 70 °C for 15 min.
  5. Cool on ice and transform 2 µl of the reaction into 50 µl competent cells.

PNCDNART

Pkg
No dye
SKU Number Type # of Samples
AIQ030 Azure Cielo 3 qPCR 96
AIQ060 Azure Cielo 6 qPCR 96
AIQ1000 Azure Cielo 3 Software Plate Setup PCR compatible
ASCIELO
Azure Biosystems Cielo qPCR System
Special Order
Quantity: