Home  >  Equipment  >  Sterilization  >  Autoclaves  > Benchmark Bioclave Autoclaves

Benchmark Bioclave Autoclaves

Item #: ASAUTOC 

1 year warranty

Chamber Volume

8L/18L/28L

Max. Pressure 8L/16L/28L

29 PSI (2 Bar) / 29PSI (2 bar) / 30.5 PSI (2 Bar)

Chamber Dims. 8L

6.7 x 12.5in. (9 x 13.75cm)

Chamber Dims. 18L

9.8 x 13.77in (24.8 x 35cm)

Chamber Dims. 28L

23 x 35in. (32 x 41.5cm)

Exterior Dims. 8L

20 x 13.5 x 12.9in (22 x 17.5 x 15.7cm)

Exterior Dims. 18L

22 x 17.5 x 15.7in (56 x 44.5 x 40cm)

Exterior Dims. 28L

56 x 44.5 x 40in (63.5 x 63.5 x 55.9cm)

Weight 8L/18L/28L

74 lbs (33 kg) / 89 lbs. (40 kg) / 209 lbs (95 kg)

Electrical 8L/18L

115 or 230V 50-60Hz

Electrical 28L

230V ONLY (accepts 208 to 240V) 50-60Hz

Power 8L/ 18L/28L

950W / 1600W / 2300W

Warranty

1 year

Benchmark BioClave™ Research Autoclaves
  • Designed specifically for the sterilization of laboratory research tools
  • Fully automatic operation – just press start
  • Internal memory for retrieving cycle data 
  • Built in water tank - no external connection needed
  • 8 L, 16 L and 28 L models - all models small enough for benchtop use

Despite the space-saving exterior dimensions of the Bioclaves, the stainless steel chambers are surprisingly large, accommodating a variety of liquids, media, instruments, glassware, plasticware, and other common research laboratory items. Available in 8L, 18L, and 28L chamber volumes, these benchtop models include a mechanical and electrical safety interlock that prevents the door from being opened until the pressure has reached zero PSI.

With a large digital LCD display and fully automatic operation, all segments of the cycle (fill, sterilize, exhaust, and dry) commence and run to completion by simply pressing the start button. An optional thermal mini-printer is also available for providing a record of sterilization parameters and a USB drive can be used to record settings and transfer them to a PC.

The 8-liter BioClave Mini is preprogrammed to meet basic sterilization needs. Temperature can be selected at either 121°C or 134°C, and the sterilization time is fully adjustable. The economical BioClave Mini is the ideal choice wherever benchtop sterilization is required and space is limited.

BioClave 18L and 28L Models offer preset cycle options (standard programs), for use with liquids, wrapped research instruments, or unwrapped instruments/plasticware. An additional option “Dry Only” is also available for additional drying time to be added to the end of a cycle. For special applications, requiring variations in cycle parameters, all settings are fully adjustable.

The Bioclave 28L features an increased chamber size with a diameter of 32cm. With this larger internal chamber, the BioClave 28 is our only model capable of sterilizing 1 and 2 liters flasks (and bottles). Despite the increased chamber size, the unit is still relatively compact, suitable for benchtop use.
 
 
 
Specifications 

Chamber Volume

8L/18L/28L

Max. Pressure 8L/16L/28L

29 PSI (2 Bar) / 29PSI (2 bar) / 30.5 PSI (2 Bar)

Chamber Dims. 8L

6.7 x 12.5in. (9 x 13.75cm)

Chamber Dims. 18L

9.8 x 13.77in (24.8 x 35cm)

Chamber Dims. 28L

23 x 35in. (32 x 41.5cm)

Exterior Dims. 8L

20 x 13.5 x 12.9in (22 x 17.5 x 15.7cm)

Exterior Dims. 18L

22 x 17.5 x 15.7in (56 x 44.5 x 40cm)

Exterior Dims. 28L

56 x 44.5 x 40in (63.5 x 63.5 x 55.9cm)

Weight 8L/18L/28L

74 lbs (33 kg) / 89 lbs. (40 kg) / 209 lbs (95 kg)

Electrical 8L/18L

115 or 230V 50-60Hz

Electrical 28L

230V ONLY (accepts 208 to 240V) 50-60Hz

Power 8L/ 18L/28L

950W / 1600W / 2300W

Warranty

1 year

PNAUTOCL

Vol
5.7 Liters
 
 
 
SKU Number Vol Style Voltage Price Quantity Add to Cart
RA-8L 8 L Steam Sterilizer 115 V
5040.61
Each
B4000-18 18 L Steam Sterilizer 115 V
6973.82
Each
B4000-28-120 28 L Steam Sterilizer 120 V
12842.86
Each
RA-PRINT N/A Printer for BioClave Series N/A
352.47
Each
RA-PAPER N/A Paper for BioClave Printer, 3 Rolls N/A
47.69
Each
BioClave Family
Benchmark Bioclave Autoclaves
Special Order
Quantity: