Looking for cold storage freezers or other cold storage equipment to protect your important samples? You’ll find what you need right here.
When it comes to cold storage, MIDSCI offers a truly vast collection; one item of which is sure to be precisely what you’re looking for. From refrigeration to liquid nitrogen and every temperature in between, we have a solution for storing your laboratory samples and reagents.
Our lab freezers include: refrigerator/lab freezer combo products, upright freezers, under-counter freezers, chest lab freezers, and enzyme/vaccine lab freezers.
Our refrigeration equipment offers various options, depending on the model you choose: superior temperature stability, cycle defrost, Energy Star compliance, and highly durable interiors and exteriors.
Our cryogenic storage options boast an immense offering for storage of anywhere from a couple hundred to 100,000 samples!
We have plenty of other cold storage equipment items that can reliably and safely store anything you need to.
COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
REFRIGERANT | EPA SNAP COMPLIANT, R290, PROPANE |
CONDENSER | FIN AND TUBE DESIGN, HIGH EFFICIENCY FAN |
EVAPORATOR | PLATE WALL |
DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
UNIFORMITY¹ (CABINET AIR) | +/- 1.0°C |
STABILITY² (CABINET AIR) | +/- 1.1°C |
MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.7°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6.5 MIN. |
ENERGY CONSUMPTION | 1.32 KWH/DAY |
AVERAGE HEAT REJECTION | 2.21 KWH/DAY (315 BTU/H) |
NOISE PRESSURE LEVEL (DBA) | 49 OR LESS INSTALLED |
PULL DOWN TIME TO NOMINAL OPERATING TEMP | 30 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
ALARMS | VISUAL AND AUDIBLE INDICATORS |
HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Stainless Steel Built-In Vaccine Refrigerator
COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
EVAPORATOR | PLATE WALL |
DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
STABILITY² (CABINET AIR) | +/- 1.2°C |
MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
ENERGY CONSUMPTION | 1.15 KWH/DAY |
AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
ALARMS | VISUAL AND AUDIBLE INDICATORS |
HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
456 Pharmacy Solid Door Refrigerator
COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
REFRIGERANT | EPA SNAP COMPLIANT, R290, PROPANE |
CONDENSER | FIN AND TUBE DESIGN, HIGH EFFICIENCY FAN |
EVAPORATOR | PLATE WALL |
DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
UNIFORMITY¹ (CABINET AIR) | +/- 1.0°C |
STABILITY² (CABINET AIR) | +/- 1.1°C |
MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.7°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6.5 MIN. |
ENERGY CONSUMPTION | 1.32 KWH/DAY |
AVERAGE HEAT REJECTION | 2.21 KWH/DAY (315 BTU/H) |
NOISE PRESSURE LEVEL (DBA) | 49 OR LESS INSTALLED |
PULL DOWN TIME TO NOMINAL OPERATING TEMP | 30 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
ALARMS | VISUAL AND AUDIBLE INDICATORS |
HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Freestanding Premier Pharmacy/Vaccine Countertop Refrigerator
- Width: 17 ¼”
- Depth: 19 ¼”
- Height: 21 ¼”
- Cycle Defrost
- 115v, 60 Hz, .90 Amps, 1/8 Hp
- Energy Consumption 0.71 Kwh/day
- Ul/c-ul Listed
- Shipping Weight: 91 Lbs.
- Energy Star Certified
- Microprocessor Temperature Controller
- Digital Temperature Display
- Audible and Visual High and Low Temperature Alarms
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
- Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
Premier Glass Door Chromatography Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Shipping Weight: 283 Lbs. Note: This Unit Requires Two (2) Outlets
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°-10°c
- Digital Temperature Display and Alarm Module
- Sample Simulated Digital Temperature Display; .1° Resolution
- Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- Sensor Error Alarm
- Power Failure Alarm
- Resettable 1-point Min/max History
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Alarm Validation (Audible, Visual, and Remote Alarm)
- Alarm Mute With Ring Back
Glass Door Built-in Vaccine Refrigerator
COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
EVAPORATOR | PLATE WALL |
DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
STABILITY² (CABINET AIR) | +/- 1.2°C |
MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
ENERGY CONSUMPTION | 1.15 KWH/DAY |
AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
ALARMS | VISUAL AND AUDIBLE INDICATORS |
HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
4.6 Cu. Ft. Built-In Pharmacy Undercounter Refrigerator
- Width: 17 3/4"
- Depth: 19 1/2"
- Height: 30 3/4"
- Cycle Defrost
- 115v, 60 Hz, .90 Amps, 1/8 Hp
- Energy Consumption 0.58 Kwh/day
- Ada Compliant
- Ul/c-ul Listed
- Shipping Weight: 85 Lbs.
- Microprocessor Temperature Controller
- Digital Temperature Display
- Adjustable Operating Temperature Range: 36°f – 46°f (2°c – 8°c)
- Refrigerator/freezer Freestanding Thermometer With 3 Year Certificate of Calibration, With Min/max Memory, °f/°c Switchable
- Audible and Visual High and Low Temperature Alarms
- 2 Probes; 1 in Air and 1 in Glycol Bottle
- Remote Alarm Contacts
Built-In Vaccine Refrigerator NSF/ANSI 456 Certified
COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
EVAPORATOR | PLATE WALL |
DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
STABILITY² (CABINET AIR) | +/- 1.2°C |
MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
ENERGY CONSUMPTION | 1.15 KWH/DAY |
AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
ALARMS | VISUAL AND AUDIBLE INDICATORS |
HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
CellTreat Cryo Tubes
- CELLTREAT Freeze Cryogenic Vials are designed for storing biological material at temperatures as low as -196°C, in the gas phase of liquid nitrogen
- Available in round bottom or self-standing options
- CELLTREAT product descriptions are based on the highest graduation mark on the vial. Other brands may name vials based on actual liquid capacity
- Self-standing re-sealable bags offer a unique storage solution
- Internal thread cap prevents contamination and uses O-ring silicone seal to ensure positive seal at any temperature.
- External thread cap features integrated leak-proof seal, a long skirt for easy one hand aseptic methods, and a thread design allowing it to be removed or sealed with a mere 1 1/4 turn
- Caps have textured ridges to provide gripping when wearing gloves
- Contrasting black graduations are large and easy to view
- Large white marking area for writing also provides backdrop to enhance black graduations
- Self-standing base interlocks with Easy Grip Workstation Rack for easy one-handed opening
Specifications
Item |
229915 |
229925 |
Pack Description |
100/Re-sealable
Bag |
100/Re-sealable
Bag |
Case Quantity |
100 |
100 |
Sterile |
Yes |
Yes |
Non-pyrogenic |
Yes |
Yes |
Autoclavable |
Yes |
Yes |
Primary Color |
Natural |
Natural |
Primary Material |
Vial:
Polypropylene |
Polypropylene |
Secondary Material |
O-Ring:
Silicone |
N/A |
Maximum Volume |
1.8
mL |
1.8
mL |
Working Volume |
1.8
mL |
1.8
mL |
Graduated |
Yes |
Yes |
Graduation Increments (Subdivisions) |
1/10
mL |
1/10
mL |
RNase/DNase Free |
Yes |
Yes |
Standard Glass Door Laboratory Refrigerator
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Microprocessor Temperature Controller
- Digital Temperature Display
- Audible and Visual High and Low Temperature Alarms
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Remote Alarm Contacts
- Adjustable Operating Temperature: 1°C to 10°C
Standard Laboratory Refrigerator With Natural Refrigerants
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Shipping Weight: 200 Lbs.
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°-10°c
- Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
- Sample Simulated Digital Temperature Display; .1° Resolution Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- Sensor Error Alarm
- Power Failure Alarm
- Resettable 1-point Min/max History
- Remote Alarm Contacts
- Alarm Validation (Audible, Visual, and Remote Alarm)
- Alarm Mute With Ring Back
High Density Urethane Laboratory Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Shipping Weight: 258 Lbs.
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°-10°c
- Digital Temperature Display and Alarm Module
- Sample Simulated Digital Temperature Display; .1° Resolution Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- Sensor Error Alarm
- Power Failure Alarm
- Resettable 1-point Min/max History
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Alarm Validation (Audible, Visual, and Remote Alarm)
- Alarm Mute With Ring Back