Specification
Variable Speed
10 to 18 RPM
Heating Element
1200 Watts
Operation Range
Ambient to 99.9oC
Temperature Controller Accuracy
+0.1OC
Temperature Display
LED
Temperature Stability
Inside Oven: +0.3oC to 68oC Inside Bottles: +0.1oC to 68oC
Temperature Uniformity
Inside Oven: +0.1oC to 68oC Inside Bottles: +0.1oC to 68oC
Interior Dimensions
14"W x 10.75"H x 10.75:D (356 x 273 x 273mm)
Bottle Capacity
Twenty (20) 35 x 150 mm Ten (10) 35 x 300 mm Four (4) 70 x 300 mm (with separate Carousel Kit)
Power
12V AC/DC from 115V/60Hz or 230V/50Hz
Crosslinker Specifications (HL-2000 HybriLinker only)
Pre-set or user-selected UV energy or UV time exposure settings
Maximum UV energy setting of 999,900 microjoules per cm2
LED displays time or energy
Internal interlocking safety system
Tactile membrane switch keypad
Five 8-watt, 254nm shortwave dual bipin discharge type tubes
Interior Dimensions: 11"W x 3.7"H x 11.5" D (280 x 95 x 292mm)
This new UV transilluminator features a space-saving design while having 16 x 19 cm UV viewing surface to accommodate large gels or multiple smaller gels. The illuminated surface is comprised of a special black glass which is easy to clean, durable and scratch resistant.
Furthermore, an array of high intensity UV bulbs coupled with an optimized filter provides even illumination across the viewing surface and allows detection of small sample quantities. The dual intensity switch can be used to lower the UV intensity to 50% to reduce DNA damage during long exposure times, or switch to high intensity (100%) for viewing weak fluorescent signals or for photo documentation.
The acrylic UV blocking cover allows safe viewing of samples and has two friction hinges on the front edge to allow angling of the cover for gel access. The cover can be positioned to 90° (straight up) to fit a gel imaging hood, such as the SmartDoc™ imaging enclosure (E5000-SD).
WARNING: Transilluminators are powerful sources of ultraviolet radiation which can cause serious damage to unprotected eyes and skin. Read the ultraviolet Caution Information before operating any transilluminators.
* Except M-10 which has standard ballast, 115V unit.
Intensity :
UV Source: Refer to the Part Numbers tab for specific wavelengths for each model
Watts: 8 watts, except M-10 which is 6 watts
Dimensions:
Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.
New electronic ballast and cutting-edge construction offers:
UV Source: 254nm, 302nm or 365nm
Watts: 25 watts
Dimensions: All Benchtop models : 13.25D x 19.13W x 5.63H in.
CL-1000 Dimensions: Exterior: 13.7 deep x 15.6 wide x 8.75 high inches (248 x 396 x 222mm)
CX-2000 Dimensions: Exterior: 17.5"W x 15"D x 9.75"H (445 x 381 x 248mm) Interior: 11.4"W x 11.3"D x 3.6"H (290 x 287 x 91mm) Depth of sample tray 11.25 Width of sample tray 11.5 Sample surface to lamp approximately 3.5 in. (89mm)
1 year warranty
Model
Part No. 115V
Wavelength
Replacement Tubes
CL-1000
95-0174-01
254nm
34-0007-01
CL-1000L
95-0228-01
365nm
34-0006-01
CL-1000M
95-0230-01
302nm
34-0042-01
CX-2000
95-0339-01
Cutting-edge construction of UVP transilluminators includes an electronic ballast for increased stability and reduced power consumption. They also have a compact size to fit conveniently in small laboratory spaces. Benchtop UV transilluminators feature a fast lamp start-up with no light flicker. The FirstLight UV Illuminators offer high sensitivity and <5% coefficient of variance (CV) across the full filter area for consistency across the entire illuminated surface.
The FirstLight® UV Illuminator represents a unique highly uniform excitation source for quantitative fluorescent imaging in a wide range of genomic and proteomic applications:
Specifications:
UV Source:
UV Grid
Wavelength:
302 nm
Intensity:
Single
UV Blocking Cover:
Included
Dimensions (WxDxH):
14x11x5.63 inches
Warranty:
2 year
Shortwave XX Series Lamps use ultraviolet radiation as a reliable and effective tool for sterilization and sanitation applications in hospitals, laboratories, pharmaceutical companies, and clinics. Work surfaces and equipment can become contaminated with bacteria which may be passed through the air or by hand infecting research projects and workers. In addition to bacteria, yeast, mold spores, germs, and viruses may also be present. Shortwave XX Series UV Lamps can kill up to 99% of these organisms. Decontaminate work surfaces with UV prior to PCR to reduce air-borne contamination during DNA sequencing. UV sterilization is particularly useful for temperature sensitive applications due to low operating lamp temperatures. Shortwave Lamps can be used in an upward facing position for purifying the air or in a downward position for sanitizing work surfaces. Hanging the lamp (brackets provided) reduces the space required on laboratory benchtops. Longwave UV Bulbs (365nm) also available for all models. 1 year warranty
Dimensions XX-15: 19.75"L x 6"W x 4.25"H XX-20: 24"L x 6"W x 4.25"H XX-40: 49.6"L x 6"W x 4.25"H Exposure Stand: 20"L x 6"W x 13"H
UltraSlim® LED Illuminator
The UltraSlim® LED Illuminator is designed for viewing stained gels on the laboratory bench, or within gel documentation systems. Safer lighting from the LED source inside the instrument produces blue light with a narrow emission peak centered at approximately 470 nm, which is more effective for the excitation of most nucleic acid and protein stains. Viewing surface is 120mm x 70mm.