Actions- This unique, new design for the Life Science Laboratory allows crosslinking
and hybridization at one location - Hybridizer and Crosslinker portions of the HL-2000 operate independently of each other
- The Crosslinker is also available as a stand-alone unit
- Temperature control (ambient to 99.9°C)
- Variable speed control (10 to 18 RPM) enabling consistent saturation of samples, whether it be for washing or hybridizing
- Large LED display
- Stainless steel internal construction
- Multiple bottle sizes, arrangements and off-set bottle positions (three bottle sizes available)
- Optional rocker plate
In addition to the hybridization oven features mentioned above, the Crosslinker features: - Preset and manual controls for ultraviolet or time exposures
- Preset exposure delivers 120,000 microjoules or five minutes of exposure
- Shortwave 254nm, 8 watt, ultraviolet tubes
- Microprocessor measures and controls UV output, ensuring maximum energy efficiency
- Large LED display continuously displays time or energy settings
- Tactile membrane switch keypad
- Window on the door allows viewing of the process yet blocks out the UV radiation
- Dimensions: 17.5W x 24H x 15D in. (445 x 610 x 381 mm)
- 1 year warranty
Specification
|
Accuris™ UV transilluminator
- 302nm midrange UV wavelength (optimal for EtBr excitation)
- Dual intensity settings (50% or 100%)
- Hinged UV Safety cover
- Use with SmartDocTM enclosure (E5000-SD) for gel imaging with a smart phone
- Compatible DNA stains: EtBr, SmartGlow™ LD and PS stain, Gel Red, Gel Green, SYBR® Green, SYBR® safe, and Diamond™ Nucleic acid Dye
- 2-yr warranty
This new UV transilluminator features a space-saving design while having 16 x 19 cm UV viewing surface to accommodate large gels or multiple smaller gels. The illuminated surface is comprised of a special black glass which is easy to clean, durable and scratch resistant.
Furthermore, an array of high intensity UV bulbs coupled with an optimized filter provides even illumination across the viewing surface and allows detection of small sample quantities. The dual intensity switch can be used to lower the UV intensity to 50% to reduce DNA damage during long exposure times, or switch to high intensity (100%) for viewing weak fluorescent signals or for photo documentation.
The acrylic UV blocking cover allows safe viewing of samples and has two friction hinges on the front edge to allow angling of the cover for gel access. The cover can be positioned to 90° (straight up) to fit a gel imaging hood, such as the SmartDoc™ imaging enclosure (E5000-SD).
Technical Specifications |
|
Light Source |
UV |
Wavelength |
302 nm |
Viewing Surface |
16 x 19 cm |
Ext. Dimensions |
10.5 x 13 x 5.5 in | 26.5 x 32.5 x 14 cm |
Electrical |
120 or 230V, 50-60Hz |
Warranty |
2 years |
- Increased ultraviolet output and intensity
- No light flicker
- Wider intensity range with variable selection (select models)
- Fast lamp start up
- Universal power supply
- Reduced electrical consumption
- Longer tube life
- Lighter weight
- Improved gel visualization and gel documentation
- UVP's patented 3UV Benchtop Transilluminator provides the selection of 365nm, 302nm and 254nm in one compact unit
- 2UV models offer 302nm and 365nm UV in one model
- Easily view gels under 365nm longwave UV for extended periods of time avoiding photonicking damage. Researchers can use the 302nm midrange to increase the fluorescence for photodocumentation. Shortwave 254nm UV is used to irradiate samples
- All Benchtop Transilluminator models are compact, lightweight units
- These 8-watt models provide a low cost alternative to the High Performance UV Transilluminators
- A variety of filter area work surface sizes are available
- Hinged, clear UV blocking cover, included with each transilluminator, is adjustable for access to the filter surface
- 2 year warranty
WARNING: Transilluminators are powerful sources of ultraviolet radiation which can cause serious damage to unprotected eyes and skin. Read the ultraviolet Caution Information before operating any transilluminators.
* Except M-10 which has standard ballast, 115V unit.
Intensity :
- Select models offer single intensity other models include variable intensity. Refer to the part numbers tab for information.
- Variable intensity settings-High/Medium/Low
- High setting allows for UV excitation of fluorophores on gels for routine photography. Medium is excellent for viewing and quick single-band excision. Low setting allows for positioning and preparation of gels, excising multiple bands, and focusing for photography.
UV Source: Refer to the Part Numbers tab for specific wavelengths for each model
Watts: 8 watts, except M-10 which is 6 watts
Dimensions:
- 3UV Models: 11D x 14W x 5.4H in. (279 x 356 x 137mm)
- 2UV Models: 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- Single UV/Variable Intensity Models (Except M-10): 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- M-10: 7.25D x 10.25W x 4.5H in. (184 x 260 x 114mm)
- Height includes UV blocking cover (all models)
Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.
Options- Gel Tools
- Converter Plates
- BioImaging Systems
95-0457-01 (115V) | M-26E | Single | 302nm | 8 watt | 21x26cm |
Single UV / Variable Intensity | |||||
95-0456-01 | M-15V | Variable | 302nm | 8 watt | 15x15cm |
95-0452-01 | M-20V | Variable | 302nm | 8 watt | 20x20cm |
95-0458-01 | M-26V | Variable | 302nm | 8 watt | 21x26cm |
95-0413-01 | M-26XV | Variable | 302 | 8 watt | 25x26cm |
2UV / Single Intensity | |||||
95-0449-01 | LM-20 | Single | 302/365nm | 8 watt | 20x20cm |
95-0459-01 | LM-26 | Single | 302/365nm | 8 watt | 21x26cm |
3UV / Single Intensity | |||||
95-0417-01 | LMS-20 | Single | 254/302/365nm | 8 watt | 20x20cm |
95-0414-01 | LMS-26 | Single | 254/302/365nm | 8 watt | 21x26cm |
- Increased ultraviolet output and intensity
- No light flicker
- Wider intensity range with variable selection (select models)
- Fast lamp start up
- Universal power supply
- Reduced electrical consumption
- Longer tube life
- Lighter weight
- Improved gel visualization and gel documentation
- UVP's patented 3UV Benchtop Transilluminator provides the selection of 365nm, 302nm and 254nm in one compact unit
- 2UV models offer 302nm and 365nm UV in one model
- Easily view gels under 365nm longwave UV for extended periods of time avoiding photonicking damage. Researchers can use the 302nm midrange to increase the fluorescence for photodocumentation. Shortwave 254nm UV is used to irradiate samples
- All Benchtop Transilluminator models are compact, lightweight units
- These 8-watt models provide a low cost alternative to the High Performance UV Transilluminators
- A variety of filter area work surface sizes are available
- Hinged, clear UV blocking cover, included with each transilluminator, is adjustable for access to the filter surface
- 2 year warranty
WARNING: Transilluminators are powerful sources of ultraviolet radiation which can cause serious damage to unprotected eyes and skin. Read the ultraviolet Caution Information before operating any transilluminators.
* Except M-10 which has standard ballast, 115V unit.
Intensity :
- Select models offer single intensity other models include variable intensity. Refer to the part numbers tab for information.
- Variable intensity settings-High/Medium/Low
- High setting allows for UV excitation of fluorophores on gels for routine photography. Medium is excellent for viewing and quick single-band excision. Low setting allows for positioning and preparation of gels, excising multiple bands, and focusing for photography.
UV Source: Refer to the Part Numbers tab for specific wavelengths for each model
Watts: 8 watts, except M-10 which is 6 watts
Dimensions:
- 3UV Models: 11D x 14W x 5.4H in. (279 x 356 x 137mm)
- 2UV Models: 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- Single UV/Variable Intensity Models (Except M-10): 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- M-10: 7.25D x 10.25W x 4.5H in. (184 x 260 x 114mm)
- Height includes UV blocking cover (all models)
Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.
Options- Gel Tools
- Converter Plates
- BioImaging Systems
95-0457-01 (115V) | M-26E | Single | 302nm | 8 watt | 21x26cm |
Single UV / Variable Intensity | |||||
95-0456-01 | M-15V | Variable | 302nm | 8 watt | 15x15cm |
95-0452-01 | M-20V | Variable | 302nm | 8 watt | 20x20cm |
95-0458-01 | M-26V | Variable | 302nm | 8 watt | 21x26cm |
95-0413-01 | M-26XV | Variable | 302 | 8 watt | 25x26cm |
2UV / Single Intensity | |||||
95-0449-01 | LM-20 | Single | 302/365nm | 8 watt | 20x20cm |
95-0459-01 | LM-26 | Single | 302/365nm | 8 watt | 21x26cm |
3UV / Single Intensity | |||||
95-0417-01 | LMS-20 | Single | 254/302/365nm | 8 watt | 20x20cm |
95-0414-01 | LMS-26 | Single | 254/302/365nm | 8 watt | 21x26cm |
New electronic ballast and cutting-edge construction offers:
- Increased ultraviolet output and intensity
- No light flicker
- Wider intensity range with variable selection (select models)
- Fast lamp start up
- Universal power supply
- Reduced electrical consumption
- Longer tube life
- Lighter weight
- Improved gel visualization and gel documentation
- High performance 25-watt UV tubes for high fluorescence and sensitivity on stained gels
- Stainless steel cover frame provide an easy clean surface and reduces cross contamination of samples
- Uniform, brilliant back-lit fluorescence illumination is enhanced with UVP's unique background uniformity screen and UVG long-life filter
- Uniformity screen is available on units with midrange or longwave UV
- The transilluminator's powerful cooling fan maintains a low filter surface temperature to prevent sample damage and maintains a constant UV intensity
- The removable and adjustable protective UV blocking cover is included with each transilluminator
- Transilluminators carry a two-year warranty
- 2 year warranty
WARNING: Transilluminators are powerful sources of ultraviolet radiation which can cause serious damage to unprotected eyes and skin. Read the ultraviolet Caution Information before operating any transilluminators.
Intensity:- Select models offer single intensity other models include variable intensity. Refer to the part numbers tab for information.
- Variable intensity settings - High/Medium/Low
- High setting allows for UV excitation of fluorophores on gels for routine photography. Medium is excellent for viewing and quick single-band excision. Low setting allows for positioning and preparation of gels, excising multiple bands, and focusing for photography.
UV Source: 254nm, 302nm or 365nm
Watts: 25 watts
Dimensions: All Benchtop models : 13.25D x 19.13W x 5.63H in.
- Height includes UV blocking cover
- Weight: 21 lb. (9.6 kg)
Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.
Part Numbers | |||||
---|---|---|---|---|---|
100-115V | 230V | Model | Intensity Style | Wavelength | Filter Size |
Variable UV Intensity | |||||
95-0420-01 | 95-0420-02 | TFL-40V | Variable | 365nm | 20x40cm |
95-0423-01 | 95-0423-02 | TFM-20V | Variable | 302nm | 20x20cm |
95-0422-01 | 95-0422-02 | TFM-26V | Variable | 302nm | 21x26cm |
95-0424-01 | 95-0424-02 | TFM-30V | Variable | 302nm | 25x30cm |
95-0421-01 | 95-0421-02 | TFM-40V | Variable | 302nm | 20x40cm |
95-0427-01 | 95-0427-02 | TFS-20V | Variable | 254nm | 20x20cm |
95-0428-01 | 95-0428-02 | TFS-26V | Variable | 254nm | 21x26cm |
95-0429-01 | 95-0429-02 | TFS-30V | Variable | 254nm | 25x30cm |
95-0430-01 | 95-0430-02 | TFS-40V | Variable | 254nm | 20x40cm |
2UV | |||||
95-0431-01 | 95-0431-02 | TFML-20 | Single | 302/365nm | 20x20cm |
95-0432-01 | 95-0431-02 | TFML-30 | Single | 302/365nm | 25x30cm |
95-0425-01 | 95-0425-02 | TFML-26 | Single | 302/365nm | 21x26cm |
95-0426-01 | 95-0426-02 | TFML-40 | Single | 302/365nm | 20x40cm |
Replacement Tubes |
Replacement Tube | 34-0073-01 | 25-watt, 254nm | |||
---|---|---|---|---|---|
Replacement Tube | 34-0072-01 | 25-watt, 302nm | |||
Replacement Tube | 34-0060-01 | 25-watt, 365nm |
- Small footprint for benchtop use
- Preset and manual controls for ultraviolet or time exposures. Preset exposure delivers 120,000 microjoules or five minutes of exposure
- Microprocessor measures and control UV output, ensuring maximum energy efficiency
- Large LED display and touch panel which displays time or energy settings
- Window on the door allows viewing of the process yet blocks out the UV radiation
- Select from models with 302nm midrange UV, 365nm longwave UV or 254nm shortwave UV Interior: 12 deep x 10 wide x 5 high inches (305 x 254 x 127mm)
- Overhead UV supplies uniform UV
- Shortwave UV model is available with choice of door (CL-1000) or drawer (CX-2000) styles
- Built-in UV sensor is calibrated at the UVP factory to ensure accuracy and reliability
- Crosslinking for attaching nucleic acids to a membrane takes seconds as compared to oven baking
CL-1000 Dimensions: Exterior: 13.7 deep x 15.6 wide x 8.75 high inches (248 x 396 x 222mm)
CX-2000 Dimensions:
Exterior: 17.5"W x 15"D x 9.75"H (445 x 381 x 248mm)
Interior: 11.4"W x 11.3"D x 3.6"H (290 x 287 x 91mm)
Depth of sample tray 11.25 Width of sample tray 11.5
Sample surface to lamp approximately 3.5 in. (89mm)
1 year warranty
|
Cutting-edge construction of UVP transilluminators includes an electronic ballast for increased stability and reduced power consumption. They also have a compact size to fit conveniently in small laboratory spaces. Benchtop UV transilluminators feature a fast lamp start-up with no light flicker. The FirstLight UV Illuminators offer high sensitivity and <5% coefficient of variance (CV) across the full filter area for consistency across the entire illuminated surface.
The FirstLight® UV Illuminator represents a unique highly uniform excitation source for quantitative fluorescent imaging in a wide range of genomic and proteomic applications:
- Electrophoretic separation and quantiation of 1D and 2D protein separations
- Solid phase immunoassay
- DNA quantitation
- RNA quantitation
Specifications: |
|
UV Source: |
UV Grid |
Wavelength: |
302 nm |
Intensity: |
Single |
UV Blocking Cover: |
Included |
Dimensions (WxDxH): |
14x11x5.63 inches |
Warranty: |
2 year |
- Lamps are lightweight.
- Models available include shortwave, longwave UV or a combination shortwave/longwave version
- Combination version comes with a snap-on wavelength selector for switching between wavelengths
- Use these lamps with the J-129 Lamp Stand (pictured) or the C-10 Cabinet
- 1 year warranty
Handheld Lamp Dimensions:
14.9"L x 3.2"W x 2.5"H
Lamp Stand Dimensions: 9.5"H x 13"L
Shortwave XX Series Lamps use ultraviolet radiation as a reliable and effective tool for sterilization and sanitation applications in hospitals, laboratories, pharmaceutical companies, and clinics. Work surfaces and equipment can become contaminated with bacteria which may be passed through the air or by hand infecting research projects and workers. In addition to bacteria, yeast, mold spores, germs, and viruses may also be present. Shortwave XX Series UV Lamps can kill up to 99% of these organisms. Decontaminate work surfaces with UV prior to PCR to reduce air-borne contamination during DNA sequencing. UV sterilization is particularly useful for temperature sensitive applications due to low operating lamp temperatures.
Shortwave Lamps can be used in an upward facing position for purifying the air or in a downward position for sanitizing work surfaces. Hanging the lamp (brackets provided) reduces the space required on laboratory benchtops. Longwave UV Bulbs (365nm) also available for all models. 1 year warranty
Dimensions
XX-15: 19.75"L x 6"W x 4.25"H
XX-20: 24"L x 6"W x 4.25"H
XX-40: 49.6"L x 6"W x 4.25"H
Exposure Stand: 20"L x 6"W x 13"H
UltraSlim® LED Illuminator
- Safer to use that standard UV transillumiators
- NO UV hazard to skin and eyes.
- NO DNA damage inherent to UV - No worries when cutting out bands for elution.
- Easy for use and gel cutting
- NO need to wear amber glasses.
- The THINNEST blue LED illuminator in the world.
- Strong blue LED for excitation.
- Uniform: <10% coefficient of variance (CV) in the central viewing area.
- Compact and Light: 30 mm in height
- Wide applications other than DNA/RNA gel visualization, such as fluorescent proteins.
- Sensitive for a wide range of fluorphores: DNA SafeStain, GelGreen, GelRed, EthBr, SYBR® Safe, SYBR Gold, SYBR Green I® & II, SYPRO® Rudy, SYPRO® Orange, Coomassie Fluor Orange stains, and Lumitein Protein Gel Stain.
The UltraSlim® LED Illuminator is designed for viewing stained gels on the laboratory bench, or within gel documentation systems. Safer lighting from the LED source inside the instrument produces blue light with a narrow emission peak centered at approximately 470 nm, which is more effective for the excitation of most nucleic acid and protein stains. Viewing surface is 120mm x 70mm.