View:

Reporter gene based Luminescent assay systems from Perkin Elmer provide a homogeneous assay with 96, 384, and 1536 well formats, no DTT (no smell formulation), Ease of storage (2 to 8°C) and shipping (at RT). Different assay formats allow for varying levels of intensity and half-life depending on your application.

  • Choose britelite plus:
    • Half-life = 30 min
    • Brightest signal = when looking for maximum sensitivity
    • Shortest half-life = for continuous processing of samples
  • Choose neolite:
    • Half-life = 150 min
    • High signal intensity, longer lasting signal = good balance
    • For both continuous and batch processing of samples
    • Best robustness (less dependent on mixing quality)
    • Less sensitive to phenol red
    • Can be stored 1 month at 22°C
  • Choose steadylite plus:
    • Half-life = 240 min
    • Longest signal half-life = for batch processing of samples
    • Super-sensitivity not needed
Item#:
ASLUMASSAY

Reporter gene based Luminescent assay systems from Perkin Elmer provide a homogeneous assay with 96, 384, and 1536 well formats, no DTT (no smell formulation), Ease of storage (2 to 8°C) and shipping (at RT). Different assay formats allow for varying levels of intensity and half-life depending on your application.

  • Choose britelite plus:
    • Half-life = 30 min
    • Brightest signal = when looking for maximum sensitivity
    • Shortest half-life = for continuous processing of samples
  • Choose neolite:
    • Half-life = 150 min
    • High signal intensity, longer lasting signal = good balance
    • For both continuous and batch processing of samples
    • Best robustness (less dependent on mixing quality)
    • Less sensitive to phenol red
    • Can be stored 1 month at 22°C
  • Choose steadylite plus:
    • Half-life = 240 min
    • Longest signal half-life = for batch processing of samples
    • Super-sensitivity not needed
Item#:
ASLUMASSAY1

Perkin Elmer's ATPlite simple and sensitive system is an excellent kit to determine cell number due to proliferation or toxicity. It effectively replaces the MTT assay and can be used instead of the 3H thymidine assays with additional analysis.

  • Choose ATPlite (2 steps):
    • Half-life> 4 hours
    • Longest half - life = for batch processing of samples
    • 2 step system with separate lysis and detection steps
    • More suited for Academia Choose
    • ATPlite 1step:
      • Measure within 30 min
      • Brightest signal (~3x the counts of ATPlite 2Steps) = when looking for maximum sensitivity
      • For continuous processing of samples
      • True 1 step system = More suited to HTS

     

    6016736
    6016731
    6016739
    6016943
    6016941
    6016947
    6016949
    Assay Protocol
    1-step
    1-step
    1-step
    2-step
    2-step
    2-step
    2-step
    Automation Compatible
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Yes
    Detection Method
    Luminescence
    Luminescence
    Luminescence
    Luminescence
    Luminescence
    Luminescence
    Luminescence
    Experimental Type
    In vitro
    In vitro
    In vitro
    In vitro
    In vitro
    In vitro
    In vitro
    One Unit Contains
    10 mL
    100 mL
    1000 mL
    300 assays
    1000 assays
    5000 assays
    10000 assays
    Product Brand Name
    ATPlite
    ATPlite
    ATPlite
    ATPlite
    ATPlite
    ATPlite
    ATPlite
    Shipping Condition
    Ambient
    Ambient
    Ambient
    Ambient
    Ambient
    Ambient
    Ambient
    Unit Size
    100 (96-well) / 400 (384-well)
    1,000 (96-well) / 4,000 (384-well)
    10,000 (96-well) / 40,000 (384-well)
    300 (96-well) / 1200 (384-well)
    1,000 assay points
    5,000 (96-well) / 20,000 (384-well)
    10,000 (96-well) / 40,000 (384-well)
    Vol Capacity
    10 mL
    100 mL
    1000 mL
    N/A
    N/A
    N/A
    N/A
Item#:
ASLUMASSAY3

Reporter gene based Luminescent assay systems from Perkin Elmer provide a homogeneous assay with 96, 384, and 1536 well formats, no DTT (no smell formulation), Ease of storage (2 to 8°C) and shipping (at RT). Different assay formats allow for varying levels of intensity and half-life depending on your application.

  • Choose britelite plus:
    • Half-life = 30 min
    • Brightest signal = when looking for maximum sensitivity
    • Shortest half-life = for continuous processing of samples
  • Choose neolite:
    • Half-life = 150 min
    • High signal intensity, longer lasting signal = good balance
    • For both continuous and batch processing of samples
    • Best robustness (less dependent on mixing quality)
    • Less sensitive to phenol red
    • Can be stored 1 month at 22°C
  • Choose steadylite plus:
    • Half-life = 240 min
    • Longest signal half-life = for batch processing of samples
    • Super-sensitivity not needed
Item#:
ASLUMASSAY2
View: