|◀ 61 - 72 of 80 ▶|
View:

BenchPress 2024 Promo!

Purchase any one PlateFuge, SureAir, MultiTherm Touch, TC9639 Thermal Cycler, Bead Bath Duo or Smart Reader 96

And get one MyFuge Mini, BenchMixer or $100 Amazon Gift Card FREE!

(PCRCENT, B5200, H5100-HCT, BSTC-96/BSTC-384/LD032, B2410, MR9600-MID/MR9600-T)

(MF8-G-VF or VM-3200-VF or AMZ-100-VF (choose 1)

 

Promo is valid 05/1/24 – 07/31/24.

Not to be combined with any offers or discounts. No institutional pricing. All terms apply.   
 

SureAir™ PCR Workstation

HEPA filter and UV light reduce cross-contamination during PC preparation
Compact, 22 x 16" footprint
Cable port allows easy use of centrifuges, vortexers, and other instruments
Includes pipette holder and shelf for storage of pipettes and tips
Provides clean air within chamber to ISO 5 standards

The Benchmark SureAirTM PCR workstation is a compact, convenient way to reduce contamination concerns and provide a clean room environment at a fraction of the space and cost. The high-powered yet quiet internal fan produces laminar flow conditions without any installation into ductwork. The included HEPA filter purifies air within the chamber, meeting IS0 5 cleanliness standards, and filters 99.97% of particles 0.3 um and larger. The double-hinged front panel provides ample workspace for convenient hand access, and can be opened fully to allow placement of equipment inside.

The SureAir is designed to keep your workspace clean easy-to-use, and organized. An included germicidal UVC light eliminates any stray DNA that may contaminate samples, and is programmed to automatically shut off after 15 minutes. To protect users, the UVC light is only operational when the
cover is closed, and will shut off upon opening the cover. Ample lighting is provided by an energy efficient LED light
source. Up to 3 standard size pipettes are accommodated by the pipette holder integrated within the storage shelf. Pipette tips and small instruments can also be stored away from the main workspace when not in use. Power cables can easilv be routed through the access port on the right side of the chamber. 

Specifications
 
UV Light:8W UVC
UV Auto-Shutoff Timer:15 minutes
Materials:UV-Resistant Polycarbonate
Outer Dimensions (W x D xH):21.7x15.7x23.3in.
Inner Dimensions (WxDxH):197x154×15.7in.
Hand Access Dimensions (W xH):197×6.3 in.
Filter:0.3 um 99.97% HEPA
Air Velocity:0.2 m/s
Electrical:115V or 230V. 50/60 Hz
Power Consumption:TOW
Weight:44 lbs
Warranty:2 years
 
Item#:
ASSUREAIRPCRS

Minigel System 9cm x 11cm & (1) 10 and (1) 14 tooth comb


Horizontal gel electrophoresis minigel system for 9cm x 11cm minigels. Includes gasketed UVT gel tray with fluorescent ruler, and (1) 10 and (1) 14 tooth comb, 1.5 mm thickness. Comb substitutions are available. Four year manufacturer warranty.

System description

The standard 0911 mini gel system includes a RapiCast™ gasketed gel tray for convenient gel casting right in the buffer chamber.

System features

The 0911 complete system includes these features:

  •     Heavy duty lower buffer chamber
  •     Interlock safety lid with attached leads
  •     Gasketed (cast in place) 9cm wide x 11cm long UV-transparent gel tray with built-in fluorescent ruler and 2 comb slots.
  •     One 1.5mm x 10 tooth comb
  •     One 1.5mm x 14 tooth comb
Item#:
ASMINGEL9AND11S

Double sided non- cooled vertical system, 10cm x 10cm


 Reflection double sided water cooled vertical system, 10cm x 10cm with or without casting base, two pack each of plain and notched glass, one acrylic blocker plate, (2) 10-well 0.8mm thickness combs, (4) 0.8 mm spacers. Four year warranty.
System Description

Run either one or two gels simultaneously on these versatile separation systems. The 10x10cm size of the system also accomodates most pre-cast gels.

Complete double sided vertical system for running one or two gels, in a 10 x 10 cm format. Unique casting bases allows both casting and running of gels without unclamping from the upper buffer chamber, providing for safer and more convenient gel handling. In addition the 1010 device will accommodate most precast gel cassettes on the market.

Water cooling feature is included for protocols that require it. Connections are easily made by attaching standard tubing over the 3/8" barbed in/out ports provided on the device. Water may be provided by tap or other temperature controlled water source. Optional alumina backer plates may be used to facilitate cooling efficiency and uniformity, and are available in the accessories list below.
System Features

The Galileo Reflection™ 85-1010 complete system includes these features:

  •     Heavy duty upper buffer chamber with cooling port connections.
  •     Lower buffer chamber.
  •     Interlock safety lid with attached leads.
  •     Casting base.
  •     Two-pack each of plain & notched glass plates.
  •     One acrylic blocker plate (used when running only one gel).
  •     Ttwo 10-well, 0.8mm thick combs
  •     Four 0.8mm thick side spacers.

System Accessories

Choose amoung these accessories to customize each system for your specific needs.

  •     Alumina cooling plate. For use with cooling systems. This plate can be sandwiched between the gel and the inner buffer chamber to improve overall temperature uniformity.
  •     Casting base. For quick, efficient and leak-proof casting.
  •     Multiple gradient caster.
Item#:
ASDOUBSIDNCVER10

ENDURO Modular Vertical Gel System


A modular system allowing PAGE, electroblotting and 2D gel electrophoresis to be carried out in the same tank, simply by changing the inserts. Users can purchase only the parts they need, or a complete combined system for a cost savings over buying all three systems separately.

  • Modular Design
  • PAGE, Electroblotting and 2D Electrophoresis
  • Quick and easy set up
  • Wide range of accessories
 
MODULAR SYSTEM 
 
The modularity of the ENDURO™ System is based on three operational inserts and a common buffer tank. All three inserts, PAGE, electroblotting and 2D electrophoresis, have their own electrode assembly that connects into the lid of the buffer tank. PAGE INSERT Set up of gels is quick and easy with the PAGE insert. A set of plates are placed on either side of the insert and held into place by the pressure bar. An additional gel may be run on each side by stacking the plates. The assembly is then placed into the casting stand for pouring the gel. After the gel is polymerized, the insert is removed from the casting stand and placed in the buffer tank.
 

ELECTROBLOTTING INSERT
 
The electroblotting insert has a capacity for 3 gels. Setting up blots is easy - gels are sandwiched in the blotting cassettes with the transfer membranes. The cassettes are then placed in the insert, which is in turn placed in the buffer tank. Coiled electrodes in the insert generate a high intensity current, allowing transfer to take place in about an hour.
 

2D ELECTROPHORESIS INSERT
 
This insert is used for running the first dimension of IEF gels. Up to ten 8 cm gels are poured in disposable capillary tubes and placed in this insert. Gasketed ports allow for easy insertion and removal of tubes. Blocking plugs are included for closing off ports that are not in use.
 

BUILT FOR SAFETY AND ENDURANCE
 
For leak-proof performance and a long service life, the buffer tank is molded from high quality acrylic. Pins on the top of the inserts ensure that the lid is placed onto the insert in the proper orientation. These pins also aid in removal of the lid. Removing the lid disconnects power to the electrodes.

 
ACCEPTS MOST PRE-CAST GELS
 
Most precast gels, including NuSep™, Bio-Rad™, Invitrogen™, and Cambrex™, can be used with the ENDURO™ PAGE System. The use of precast gels saves time by eliminating the need to pour gels and wait while they polymerize.

 
WIDE RANGE OF ACCESSORIES
 
A variety of combs and spacers of varying widths are available to customize your ENDURO™ system. All are color coded and clearly marked for easy identification. Both notched and plain plates can be purchased with spacers permanently bound for easy set up. Additional fiber pads and replacement cassettes are also available as well as capillary tubes, blanking ports and tube supports. Cooling packs are also available to help reduce buffer temperature during higher voltage or longer runs.
Item#:
ASEDIROMOVERGES

Minigel System w/ 4 comb slots, 12 cm x 14 cm

Horizontal gel electrophoresis system for 12cm x 14cm minigels. Includes gasketed UVT gel tray with fluorescent ruler, and (1) 12 and (1) 20 tooth comb, 1.5 mm thickness. Comb substitutions are available. Four year manufacturer warranty.
 
System Description

This flexible system from Galileo is the perfect personal unit for a wide range of separation needs, and our most popular model.

Unit features RapidCast trays for quick in-unit gel casting of 12cm wide by 14cm long gels.

Choose a complete system or build your own custom unit from the many system components we offer.  The NEBT-80-1214 gel system is supplied with a RapidCast™ gasketed gel tray for convenient gel casting directly in the buffer chamber.  Choose from a wide variety of comb options.  All are compatible with Owl Separation Systems B2A or similar devices.  The teeth on combs marked as "microtiter" are uniformly spaced for easy loading with multichannel pipettors.System features

System Features

The Galileo 1214 complete system includes these features:

  •     Heavy duty lower buffer chamber
  •     Interlock safety lid with attached leads
  •     Gasketed (cast in place) 12cm wide x 14cm long UV-transparent gel tray with
  •     built-in fluorescent ruler and 2 comb slots.
  •     One 1.5mm x 12 tooth comb
  •     One 1.5mm x 20 tooth comb

System Options
 
The Galileo 1214 unit can be also be ordered with our new automatic buffer recirculation system (80-1214-R) or with installed buffer ports for connection to an external buffer recirculation system (80-1214-BEP)
Item#:
ASMINGEL412AND14

Qamp Mini Thermal Cycler

  • Compact in Size: 102 x 136 x 104 mm
  • Preprogramed Chip: with unlimited applications
  • Touch Start: One Button to Go!
  • LCD Display: for customers to define status easily!
  • Portable: Only 1 kg
Qamp Mini is designed to achieve polymerase chain reaction (PCR) for the amplification of the targeted DNA in a miniature device making molecular biology more fun in the field. The Qamp Mini contains a centrally positioned Peltier heating and cooling module for 1-8 samples.  The design leads to accuracy in analysis and cost efficiency without sacrificing performance and quality.  With the compact size and One-Click to Go design Qamp Mini is the ideal instrument for laboratories or classrooms and in the fields of epidemiology, veterinary, food testing, pathogen detection, ecology, archaeology research and others. 


Specifications:

Sample Number8 (2 x 4 wells)
Temperature Range4°C - 99°C
Max Heating Rate (°C/sec.)4.6°C
Max Cooling Rate (°C/sec.)3.4°C
Temperature Accuracy± 0.4°C
Temperature Uniformity
Across Block
± 0.4°C
Max No. of Cyclesunlimited
Max No. of Stepsunlimited
DisplayLCD
Heated Lid105°C Fixed (pre-heat to 60°C)
Dimensions (L x W x H)10 x 13 x 10 cm
Weight1 Kg
PowerVAC 100-240, 50/60 Hz, 120 W
Item#:
ASQAMPMINI

Electrophoresis System Bundle


Package Includes:

  • Complete PR1MA™ myGel™ Mini system (E1101; includes gel box, power supply, and casting sets)
  • SmartDoc™ 2.0 Gel Viewing and Smart Phone Imaging System (E5001-SDB)
  • SmartGlow DNA Stain, 1.0 mL (BE4500-PS or BE4500-LD)
  • Agarose LE, 100 grams
Item#:
ASESYSBUNDLE

Horizontal Gel System, 15cmW x 25cmL


Galileo large gel systems are designed for high resolution of complex analytes. All units feature long run lengths, with medium to high capacity units available. High quality 9mm thick rugged acrylic construction, resists cracking and warping.
 
Your safety ensured with interlocking lid, protected sockets and permanently attached power cords. Epoxy sealed electrode connections, resist corrosion and leaks. Gold plated banana plugs.
Meets or exceeds IEC1010-1 standards. Safe & Reliable UV transmissible gel trays with built-in fluorescent rulers.

Large units feature trays with multiple comb slots for veratility. Machined finger grooves on the tray sides for easy and sure handling. Wide range of comb configurations, including multi-channel capability. Selected units available with buffer recirculation capabilities. Combs specifications clearly marked on each comb. Optional casting methods for flexibility, convenience and speed.

Convenient & Versatile
 

  • Exceptional resolution.
  • Platinum electrodes configured to provide uniform field for straight runs.
  • Multiple comb slot options for a wide range of sample and run-length configurations.
Item#:
ASHORIZGELSY15
Gel Size: 20cm(W) x 25cm(L)
Buffer volume: 1200ml

The IB56000 HR2025 is a high resolution system ideal for separation of nucleic acids  in agarose gels. It is also designed for rapid screening of PCR fragments, RFLP analysis or 
plasmid screening, field inversion, genomic DNA separations and electrophoresis  procedures requiring recirculation. Constructed of 3/8" cast acrylic to provide years of 
trouble-free service. Withstands high voltage and high temperatures and will not warp or crack like molded units do.

This System Comes Complete with:

  • Buffer Tank
  • Patented Vented Lid
  • IB56020 UVT Casting Tray
  • IB56030 Casting Fixture
  • Two, 2.0mm x 20-tooth combs
  • Power Cords
  • Bubble Level
  • Buffer Ports
  • 4 year warranty

 

Specifications:

Unit Dimensions: 8.3cm(H) x 26.7cm(W) x 39.4cm(L)

Gel Dimensions: 20cm x 25cm

Maximum sample capacity: 160 samples (4 combs, 40 samples each)

Buffer Capacity: 1200ml

Distance between electrodes: 35cm

Item#:
ASPCRELCTP5
Gel Size: 25cm(W) x 25cm(L)
Buffer volume: 1500ml

This high throughput system is designed to complete analysis of up to 200 samples 
from microtiter plates and is ideal for running all types of precast gels. The large format 
can run gels in less than 30 minutes.

 

Specifications:

Unit Dimensions: 8.3cm(H) x 26.7cm(W) x 39.4cm(L)

Gel Dimensions: 25cm x 25cm

Maximum sample capacity: 300 samples (6 combs, 50 samples each)

Buffer Capacity: 1500ml

Distance between electrodes: 35cm

This System Comes Complete with:

  • Buffer Tank
  • Patented Vented Lid
  • IB57020 UVT Casting Tray
  • IB57030 Casting Fixture
  • Four, 2.0mm x 50-tooth combs
  • Power Cords
  • Bubble Level
  • Buffer Ports
  • 4 year warranty
Item#:
ASPCRELCTP4

Gel Size: 10cm(W) x 15cm(L)
Buffer volume: 500ml

The MP-1015 is the ideal Multi-Purpose gel box for both extended high resolution, linear runs, and economical quick screens. The MP-1015 contains buffer recirculation ports for long runs requiring recirculation. The MP-1015 is constructed of 3/8" thick, cast acrylic, to withstand high voltages and temperature extremes. Unlike single piece molded units, the MP1015 will NOT warp or crack during extended use. This unit is designed to provide years of continuous operation.

Specifications:

Construction: Buffer tank is constructed of 3/8" thick, cast acrylic. Casting tray bottom is constructed of UV transmittance cast acrylic to allow viewing of the gel with a UV light source

Unit Dimensions: 7cm(H) x 16.5cm(W) x 30.5cm(L) Gel Dimensions: 10cm x 15cm

Shipping weight: 4.5 Lbs.

Distance between the electrodes: 27cm

Maximum Sample Capacity: 80 samples (4 combs, 20 samples each)

Buffer Capacity: 500ml

The maximum suggested applied voltage for the electrophoresis of DNA in agarose gels using the IB53000-MP1015 is 140 volts. In a 1% TBE gel, this translates into a run time of approx. 1 hour. Lower voltages can be used of course, and as a general rule a 70 volt run will take twice as long as a 140 volt run. Higher voltages can be used to decrease run time however, higher voltages can produce excessive heat and decrease sample resolution.

Complete System Includes:

  • Buffer Tank

  • Patented Vented Lid

  • IB53020 UVT Casting Tray

  • IB53030 Casting Fixture

  • Two, 2.0mm x 16-tooth combs

  • Power Cords

  • Bubble Level

  • Buffer ports

  • 4 year Warranty
Item#:
ASPCRELCTP3

Gel Size: 7cm(W) x 10cm(L)
Buffer volume: 250ml

Designed for Quick Screening and rapid, linear separation of nucleic acids. The QS710 requires 
minimal set-up and provides excellent band resolution and consistent lane-to-lane mobility 
for accurate results. A versatile system great for applications requiring quick screens such as 
fragment analysis and recombinant screening.

 

Specifications:

Construction: Buffer tank is constructed of 3/8" cast acrylic.

Casting Tray bottom is constructed of UV Transmittance cast acrylic to
allow viewing of gel with a UV light source

Unit Dimensions: 6.4cm(H) x 11.4cm(W) x 22.2cm(L)

Gel Dimensions: 7cm x 10cm

Distance between the electrodes = 19.3cm

Maximum sample capacity = 30 samples (2 combs / 15 samples ea)

Buffer Capacity = 250ml

Shipping weight = 3.0 lbs.

The maximum suggested applied voltage for the electrophoresis of DNA in agarose gels using the QS710 is 100 volts. In a 1% TBE gel, this translates into a run time of approx. 1 hour. Lower voltages may be used, of course, and as a general rule, a 50 volt setting will take twice as long as a 100 volt setting.

The suggested run parameters for the electrophoresis of RNA in agarose gels containing formaldehyde are 60 - 80 volts.

Complete System Includes:

  • Buffer Tank
  • Patented Vented Lid
  • IB51020 UVT Casting Tray
  • IB51025 Casting Fixture
  • Two, 1.5mm x 8-tooth combs
  • Power Cords
  • Bubble Level
  • 4 year warranty
Item#:
ASPCRELCTP2
|◀ 61 - 72 of 80 ▶|
View: