S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Plastic Instrument Tray, Polypropylene, Autoclavable
- Dimensions (L x W): 24 x 14-Inch (610 x 350mm)
- Autoclavable at 121°C for sterile applications
- 12mm deep vertical sides
- Material Type: Polypropylene
- Color: White
- Sold Individually
- Manufacturer Part No: GSI-TWR022
Protran nitrocellulose membranes are the most frequently specified transfer media in the world for a wide range of applications. Protran membranes are manufactured using 100% pure nitrocellulose to ensure the highest binding capacity possible. Other membranes referred to as "nitrocellulose" may actually contain large amounts of cellulose acetate, which will lower the protein binding capacity. In addition to high binding capacity, Protran nitrocellulose membranes inherently have very low background. The superior surface properties of the membrane guarantees superior signal-to-noise ratios, without the need for stringent washing conditions. Unlike PVDF membranes, Protran nitrocellulose requires no methanol pre-wetting step. This makes it the membrane of choice for proteins that prefer aqueous environments. Prior to transfer, the membrane is simply wet in water and then in the transfer buffer, with no other necessary pre-treatment steps. Protran membranes exhibit the best handling strangth of all pure nitrocellulose membranes.
Features:
- High binding capacity (80-150g/cm2) of proteins and nucleic acids.
- 100% pure nitrocellulose, with no cellulose acetate added, ensures the highest binding capacity possible.
- Compatible with virtually all standard detection methods.
- Low background - NC surface properties guarantee superior signal-to-noise ratios.
- Triton-free matrix with low extractable levels will support the cell growth essential for colony blotting, plaque lifts, and tissue culture applications.
- Available in many sizes and formats to fit different transfer devices and gel chambers.
Grade |
Pore Size |
BA75 |
0.05µm |
BA79 |
0.1µm |
BA83 |
0.2µm |
BA85 |
0.45µm |
Pall® Acrodisc® Ion Chromatography Syringe Filters
These syringe filters are specifically designed for ion chromatography
applications and optimized to provide the most consistent results when
analyzing ionic species. Supor® (hydrophilic polyethersulfone) membrane
exhibits very low drug and protein adsorption.
- Consistent results for more accurate data
- Low Conductivity for reduced background noise
- Certified for low levels of common ions
- Excellent for filtration of dissolution samples
Ribbon Size: 2.50" (64mm) Wide x 244' (74m) Long
Printer: For use in Zebra printer model TLP 2844
U of M: Roll
Polystyrene Plasteur Pasteur Pipets
- The Plasteur Plastic Pasteur Pipet offers the aspirating precision of a glass pipet and the safety benefits of plastic
- Fine tip is ideal for precision aspirating
- No more broken glass: more durable than standard glass pipets
- No damage during shipping and handling as compared to traditional glass pipets
| Sterile | Yes |
| Non-pyrogenic | Yes |
| Primary Color | Clear |
| Primary Material | Polystyrene |
| Graduated | No |
| RNase/DNase Free | Yes |
Isohelix™ Genefix™ Saliva DNA Microbiome Collection & Stabilization
Collection & Stabilization Devices for Saliva Microbiome DNA
MFX Is An Easy To Use Saliva Collection Device That Stabilizes Microbiome DNA For Over 12 Months
- Ambient Storage – No Expensive Storage or Transport
- Instant Stabilization – Provides a Snapshot of the Saliva Microbiome
- No Trace DNA Contamination – Reliable Results
- Compatible to Most Downstream Chemistries
- Non-Toxic – Non-Hazardous – Easy to Use
- Unique Funnel Design Prevents Spillages or Buffer Flow Back
- Suitable for Field, Home Use & Clinic-Based Sampling
- Collection Tube Specified to 95kPa for Leak Proof Mailing
NO FREEZING REQUIRED - Microbial DNA is Perfectly Preserved at Room Temperature
Pall® VacuCap®
& VacuCap PF Vacuum Filtration Devices
Innovative Bottle-Top Filters for Fast Vacuum Filtration of
100 mL to 5 L of Aqueous Solutions Vaccum Filtration Made Easy.
- Explore how VacuCap filter unit can:
- Replace current vacuum filter systems
- Simplify workflow
- Maximize filtration
- Filter faster. Supor® membrane provides high flow rates.
- No need to constantly refill upper fluid reservoir.
- Draws directly from the mixing reservoir.
- Eliminates the possibility of contamination from transfer steps. Filters directly into the desired container.
- Match filter to sample volume by choosing from two sizes.
- Available built-in prefilter increases throughput of particulate-laden solutions such as serum-containing media.
- Environmentally-friendly with minimal plastic waste.
- Patented small design accepts a variety of collection vessels and reduces storage space and waste.
- TA version available with tubing attached to each device for maximum convenience.
- Gamma irradiated, eliminates potential contamination by EtO residuals.
- The feedline accessory kit includes tubing and a glass sinker
Pall® AcroPrep™ 96 Filter Plates
Optimized for a Variety of Applications Requiring Larger Per Well Volume Processing
- Plates are constructed of chemically resistant, biologically-inert polypropylene
- Robotics-friendly design has single piece construction, designed in accordance with the ANSI/SBS X-2004 specifications
- A serialized barcode label allows use in automated tracking systems
- Proprietary sealing technology individually seals each well, eliminating crosstalk
- Available in a variety of membrane configurations
- Extended flow directors eliminate splattering and crosstalk of filtrate
|
Item |
Description |
|
5041 |
Pall®
AcroPrep™ 96 Filter Plates, PP/1.2SUPOR, natural (10/pkg) |
|
5051 |
Pall®
AcroPrep™ 96 Filter Plates, 1 mL - 1.0 µm, glass fiber media (5/pkg) |
|
5053 |
Pall®
AcroPrep™ 96 Filter Plates, 1 mL - 3.0 µm, glass fiber media/0.2 µm Bio-Inert
membrane (5/pkg) |
|
5055 |
Pall®
AcroPrep™ 96 Filter Plates, 1 mL - 0.2 µm, PTFE membrane (5/pkg) |
|
5056 |
Pall®
AcroPrep™ 96 Filter Plates, 1 mL - 0.45 µm, PTFE membrane (5/pkg) |
|
5062 |
Pall®
AcroPrep™ 96 Filter Plates, 1 mL - 0.8 µm, Mustang Q membrane (5/pkg) |
|
5063 |
Pall®
AcroPrep™ 96 Filter Plates, 1 mL - 0.8 µm, Mustang S membrane (5/pkg) |
|
5065 |
Pall®
AcroPrep™ 96 Filter Plates, 1 mL - 1.2 µm, Supor membrane, (5/pkg) |
PR1MA PCR Tool
Tool for opening and/or closing PCR strips or single tubes. Compatible with flat or domed caps. Can also be used for sealing film.
Storage Box with Telescoping Lid
- Tubes of varying lengths are accommodated by the telescoping lids of these boxes.
- Made of polypropylene, they can be used for freezer storage and autoclaved.
- Lids are alphanumerically labeled.
- Boxes hold 0.5 mL, 1.5/2.0 mL and 5 mL tubes as well as cryovials and chromatography vials.
- Freezer storage racks and numeric ID grids are available for the 1.5/2.0 mL boxes.
Pall® FluoroTrans® W PVDF Transfer Membranes
- Sensitive Protein Detection with Low Background and Very Low Burnthrough
- Naturally hydrophobic polyvinylidene fluoride is ideal for a wide variety of protein-analysis applications. The family of FluoroTrans® media are white, microporous solid phase supports that bind proteins tenaciously via hydrophobic interactions.
- High sensitivity for small peptides.
- High protein binding capacity. Typically absorbs 50% more protein than nylon or nitrocellulose.
FluoroTrans® W membrane is optimized for Western transfer applications. This membrane allows for sensitive protein detection with low background and very low protein burnthrough. Immobilized proteins can be visually detected with Coomassie blue, Amido Black, Ponceau S, and colloidal gold.
Tyvek Coveralls with Open Wrists & Ankles
Tyvek® 400 garments are composed of flash spun high density polyethylene which creates a unique, non-woven material available only from DuPont. Tyvek® 400 provides an ideal balance of protection, durability and comfort of any limited use fabric technology. Tyvek® 400 fabric offers an inherent barrier against particles (down to 1.0 micron in size). Protection is built into the fabric itself; there are no films or laminates to abrade or wear away. Tyvek® 400 fabric's durability advantage over microporous film fabrics delivers consistently better barrier, even after wear and abrasion. Applications include: lead and asbestos abatement/remediation, general maintenance/operations, spray painting, general clean-up.
- Comfort fit design based on extensive wearer input to provide our most comfortable garment design that: enables a greater range of movement while stretching and bending, provides a more tailored fit, offers reinforcement in high stress areas for fewer blowouts, utilizes a longer zipper for easier donning and doffing and an elastic waist to better position the garment.
- Laydown collar
- Open wrists
- Open ankles
- Stormflaps