S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Lab Equipment
Shopping for scientific equipment has never been as easy as browsing through our catalog; rich in premium, ergonomic, durable, and affordable lab equipment of all sorts.
Our stock of lab equipment is so vast that we can only offer a small preview here but, rest-assured, we firmly believe that any lab equipment you buy from MIDSCI™ is going to satisfy your needs.
MIDSCI™ offers accurate balances, quiet centrifuges, ergonomic chairs, powerful homogenizers, and durable hotplates.
We also carry incubators known for temperature uniformity, microplate readers with artificial intelligence onboard, microscopes with infinity-corrected optics, and water purification systems that can save you money.
Many of our items come with amazing warranties and some carry additional discounts.
SmartReader™ MultiMode Plate Reader
- Intuitive, 10-inch color touch screen
- Stand-alone system with optional PC software (FDA CFR Part 11)
- Monochromator-based system for UV through visible absorbance
- Filter module system for fluorescence assays
- Advanced PMT detector for luminescence assays
- Optional automatic injection modules for flash luminescence
- ELISA Assays
- Colorimetrics Assays (Bradford, Lowry, etc.)
- Enzyme Kinetics
- Spectral Scanning
- DNA & RNA Analysis
- …and more
Hettich Rotofix 32A Centrifuges
Rugged and Indispensable
The ROTOFIX 32 A is a rugged, versatile centrifuge for routine laboratory
tasks in doctors' practices and small hospitals. Equipped for several
clinical chemistry applications including cytology. With a wide variety of
accessories, the ROTOFIX 32 A is also used for the preparation of samples in
industrial and research laboratories.
Model |
ROTOFIX 32 A |
Max. Capacity |
4 x 100 ml / 6 x 94 ml |
Max. RPM/RCF |
6,000/4,226 |
Temp. Control |
Ambient |
Dims. (HxWxD) mm |
257 x 366 x 430 |
Dims. (HxWxD) in |
10 x 14 x 17 |
Weight (kg) |
23 |
Weight (lbs) |
51 |
Power Supply |
120 V |
Warranty |
5-years |
Rotor Type(s) |
Swing-out, Fixed-angle, Cytology |
Benchmark™ BenchMasher™ 400 Paddle Blender
- Contamination free mixing/homogenizing of samples
- Touch screen control with variable mixing speed and temperature control
- Adjustable stroke length
- Built in UV light for chamber decontamination
The BenchMasher™ provides fast and effective mixing, ensuring consistent homogenization. It is ideal for preparation of samples were eliminating contamination is critical, such as pathogen and microbial detection in food and water filters. However, its use is not limited to those areas - the BenchMasher™ has applications anywhere larger solid samples need broken down or products such as powders and polymers need mixed.
Samples up to 400 mL are conveniently loaded in the sterile blender bags which are sealed upon closing the door. Mixing paddles rapidly strike the bags, producing thorough mixing and homogenization without ever directly contacting the sample. Programming is user friendly - mixing speed and cycle time are easily adjusted on the large, full color touch screen. Paddle position can be adjusted to ensure efficient processing of samples. For applications requiring thermal regulation (such as Trichinella testing in meat) the chamber can be heated and maintained at temperatures up to 65°C.
The door is removable for access to the chamber and stainless steel mixing paddles. Each paddle includes a convenient rubber cover that is easily removed or replaced. A UV light (254 nm) is built into the chamber and can be activated at any time to perform complete decontamination.
Specifications
Speed |
3-12 strokes/second |
Timer |
1 second to 100 minutes or continuous |
Paddle
distance |
0 to 50 mm |
Temperature
range |
Ambient to 65°C |
Ambient
operating temperature |
2°C to 35°C |
Bag
size (WxH) |
16-18 cm x 25-30 cm |
UV
Bulb |
254 nm |
Dimensions
(WxDxH) |
9 x 16.5 x 14 in. | 23 x 42 x 33 cm |
Weight |
42 lb | 19 kg |
Electrical
|
120 V, 50 Hz |
Warranty |
2 years |
Replace Millipore QTUM000EX, QTUMOOOEX Quantum EX (Organics Resin) cartridge filter for Milli-Q Academic, Milli-Q Biocel and Milli-Q Synthesis systems etc.
Product Descriptions:
This product is designed for removing ionic and organic contaminants below trace level to match the water quality required for your application.
Purification technology:
Ion-Exchange
Activated Carbon
Ordering Information:
RephiLe Catalog No. |
Description |
Millipore Catalog No. |
RRQTUM0EX |
RephiSolo U Pack EX |
QTUM000EX |
Available to the following Millipore systems:
Direct-Q 3/5 older version
Milli-Q Academic
Milli-Q Biocel
Milli-Q Gradiant
Item #185MICRO24-BC is no longer available please order Item # 185MICRO24 Instead
MIKRO 185 MICROCENTRIFUGE
Affordable and versatile micro centrifuge for your demanding budget and requirements
The MIKRO 185 offers the choice of 4 rotors, offering microliter, pediatric and spin column packages & bio-containment lids for applicable rotors.
Protect your samples
An 18-place rotor for spin column kits is designed to protect the tube cap from breaking during centrifugation and is also available with bio-containment lid.
Adjustable parameters for flexible application control.
Adjust time, speed (RPM), RCF and braking with the easy to use LCD display. Pulse key available allowing you to hold and press start key for short centrifugation runs.
Visual and audible end-of-cycle notification for a productive work-flow.
Customizable and independent control of visual and/or audio alarms can be set for end of cycle notification. This provides an across-the-room indication that your unit is ready for the next operation.
Diamond White is a super high quality line of slides that compares to German & Swiss made slides but at substantial savings. Our slides are produced from water white glass sheets and are so clear you will see the sample not the slide.
Diamond White Glass microscope slides are ideal for all routine applications, automated instruments, long-term storage, fluorescence studies and where accuracy and the highest optical quality are of paramount importance. The glass is specially formulated for minimal oxidation, which ensures sample integrity during long-term storage. Increased hardness and molecular stability of the slide surface provides more accurate experimental results and diagnoses.
Available in plain, frosted, color coded, charged and instrument specific versions. All slides are double cellophane packaged to protect against moisture and foreign particles.
STAT FAX 4200 Microplate Reader
The Stat Fax 4200 Microplate Reader is a compact, microprocessor-controlled, multi-purpose
photometer system designed to read and calculate the results of assays, which are read in 96
well microtiter plates or strip trays. The microplate reader may be used for in-vitro diagnostics. It is a user-programmable open system with selectable plate formatting, alphanumeric test naming, automatic interpretation options, duplicate well options, curve plotting and editing, flags and error messages from which the user can create a menu of pre-programmed assays for instant recall. This instrument is intended to be used as a stand-alone instrument without a PC but it has a connection in the event a user wishes to download results.
Stat Fax 4200 reads monochromatically (optional) or bichromatically (optional) and has two
models:
- Four-filter model (405, 450, 492, and 630 nm)
- Six-filter VIS model (405, 450, 492, 545, 600, and 630 nm)
Substitute filters in the range of 405 nm – 750 nm are available on special order
models.
Stat Fax 4200 accepts all standard microplates. Trays containing microstrips may also be read
whether they are 12 wells in length, 8 wells or even partial strips.
The software allows the operator to create, edit and store assays. Standard
curves are also stored in this memory. Test protocols remain stored until either changed or
deleted by the user.
TheStat Fax 4200’s optical system provides an economical and low maintenance design which reads 8 wells simultaneously. A 96 well plate can be read and printed in the absorbance mode in approximately ten seconds. Light from a lamp installed in a sealed light-tight compartment is filtered using a rotating filter wheel. The filtered light is then divided into 8 channels using a fiber optic bundle. The plate carrier precisely positions each row of 8 wells into the optical path for reading. Light passing through the 8 wells is directed to 8 photo-detectors. The filter wheel moves to a second position to read the 8 wells at a second wavelength. Using bichromatic differential absorbance values corrects for optical imperfections in the plastic wells and removes the effects of meniscus and turbidity.
Specifications: |
|
Photometric |
|
Linear Measurement Range: |
0.0 to 4.0 Absorbance Units (A) |
Photometric Accuracy: |
+/- (1% +/- 0.010) 0.0 through 1.5 ABS |
+/- (2% +/- 0.010) 1.5 through 3.0 ABS |
|
Stability: |
Drift of no more than 0.005A in 8 hours |
Light Source: |
Halogen lamp with lamp saver feature |
Standard Wavelengths: |
405, 450, 492, and 630nm. 6-filter: 405, |
450, 492, 545, 600, and 630nm. Filter |
|
options from 405nm to 700nm |
|
Filter Type: |
IAD hardcoat interference, 10nm half bandpass |
Vessel: |
Standard 96-well microplates, or strip trays |
Electronic |
|
Display: |
Interactive touch screen 5.7” (14.5cm) |
LCD, color graphic display |
|
Printer: |
Thermal 64 characters per line, plus graphics |
Power Requirements: |
100-240V AC, 1.2A, 50-60Hz (universal |
input, auto sensing) |
|
Interface: |
USB mouse; USB port used for thumb |
drive interface for firmware updates |
|
(mouse not included; thumb drive not |
|
Speed: |
Reads absorbance of 96 wells in about |
10 seconds |
|
Calculation Modes: |
Factor, Single Standard, Point-to-Point, |
Regression, Cubic Spline, Cut Off Mode |
|
Test Storage: |
Stores 120 tests; stores all parameters |
including wavelengths, calculations, unit |
|
codes, linear and normal ranges, |
|
standard values, test names, and |
|
previous standard curve |
|
Dimensions: |
Approximately 13.5”Wx17”Dx8-1/4”H |
(34.3cmx43.2cmx21cm) weight 12 lbs |
|
(5.5kg) |
Important characteristics
- Temperature range: room temperature plus 5 °C to 100 °C
- APT.line preheating chamber technology
- gravity convection
- Adjustable exhaust air flap
- Controller with timer functions
- Inner door made of tempered safety glass
- 2 chrome-plated racks
- Stackable
- Class 3.1 independent temperature safety device (DIN 12880) with visual temperature alarm
- Computer interface: RS 422
Order number |
9010-0189 |
Performance Data Temperature |
|
Heating-up time to 37 °C [min] |
59 |
Recovery time after 30 seconds door open at 37 °C [min] |
20 |
Temperature fluctuation at 37 °C [± K] |
0.2 |
Temperature range 5 °C above ambient temperature to [°C] |
100 |
Temperature variation at 37 °C [± K] |
0.5 |
Electrical data |
|
Nominal power [kW] |
0.2 |
Phase (Nominal voltage) |
1~ |
Power frequency [Hz] |
60 |
Rated Voltage [V] |
120 |
Unit fuse [A] |
12.5 |
Doors |
|
Unit doors |
1 |
Internal Dimensions |
|
Depth [in] |
10.91 |
Height [in] |
13 |
Width [in] |
8.75 |
Measures |
|
Interior volume [cu.ft.] |
0.7 |
Load per rack [lbs] |
26 |
Net weight of the unit (empty) [lbs] |
60 |
permitted load [lbs] |
55 |
Outer dimensions |
|
Depth net [in] |
20.49 |
Height net [in] |
19.5 |
Wall clearance back [in] |
6.3 |
Wall clearance sidewise [in] |
3.94 |
Width net [in] |
17.14 |
Environment-specific data |
|
Energy consumption at 37 °C [Wh/h] |
11 |
Fixtures |
|
Number of shelves (std./max.) |
2/4 |
With its wide temperature range and extensive program functions, a BINDER cooling incubator ensures reproducible conditions in the microbiology laboratory.
Features:
- Temperature range: 4 °C to 100 °C
- preheating chamber technology
- Adjustable fan speed
- Electric cooling with Peltier module
- Controller with time-segment and real-time programming
- Display via LCD monitor
- Input via pushbutton/rotary knob
- Inner door made of tempered safety glass
- 2 stainless steel racks
- Units up to 115 liters are stackable
- Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
- Computer interface: Ethernet
- Data recording and USB interface
Series KT Specifications:
Description |
KT 53 |
KT 115 |
KT 170 |
Part # |
9020-0312 |
9020-0314 |
9020-0310 |
Basic data |
|||
Interior volume [L] |
53 |
102 |
163 |
Housing dimensions not incl. fittings and connections |
|||
660 x 635 x 630 |
860 x 715 x 655 |
860 x 1.025 x 655 |
|
Interiors dimensions |
400 x 400 x 334 |
600 x 455 x 355 |
600 x 765 x 355 |
Technical data: Temperature |
|||
Temperature range [°C] |
4...100 |
4...100 |
4...100 |
Temperature variation at 37 °C [± K] |
0,3 |
0,3 |
0,4 |
Temperature fluctuation max. [± K] |
0,1 |
0,1 |
0,1 |
Recovery time after door was opened for 30 sec. at 37 °C [min] |
2 |
3 |
3 |
Item No. |
Series |
9010-0314 |
Series BF - Incubators Avantgarde.Line with forced convection |
9010-0316 |
Series BF - Incubators Avantgarde.Line with forced convection |
9010-0320 |
Series BF - Incubators Avantgarde.Line with forced convection |
Important characteristics
- Temperature range: room temperature plus 5 °C to 100 °C
- APT.line preheating chamber technology
- Adjustable fan speed
- Adjustable exhaust air flap
- Controller with timer functions
- Inner door made of tempered safety glass
- 2 chrome-plated racks
- Class 3.1 independent temperature safety device (DIN 12880) with visual temperature alarm
- Computer interface: RS 422
Order number |
9010-0242 |
Performance Data Temperature |
|
Heating-up time to 37 °C [min] |
12 |
Recovery time after 30 seconds door open at 37 °C [min] |
5 |
Temperature fluctuation at 37 °C [± K] |
0.1 |
Temperature range 5 °C above ambient temperature to [°C] |
100 |
Temperature variation at 37 °C [± K] |
0.4 |
Electrical data |
|
Nominal power [kW] |
0.85 |
Phase (Nominal voltage) |
1~ |
Power frequency [Hz] |
60 |
Rated Voltage [V] |
120 |
Unit fuse [A] |
12.5 |
Doors |
|
Unit doors |
2 |
Internal Dimensions |
|
Depth [in] |
19.7 |
Height [in] |
31.52 |
Width [in] |
39.4 |
Measures |
|
Interior volume [cu.ft.] |
14.1 |
Load per rack [lbs] |
77 |
Net weight of the unit (empty) [lbs] |
320 |
permitted load [lbs] |
198 |
Outer dimensions |
|
Depth net [in] |
30.14 |
Height net [in] |
40.4 |
Wall clearance back [in] |
6.3 |
Wall clearance sidewise [in] |
3.94 |
Width net [in] |
48.7 |
Environment-specific data |
|
Energy consumption at 37 °C [Wh/h] |
56 |
Fixtures |
|
Number of shelves (std./max.) |
9-Feb |
Item No. |
Series |
9010-0242 |
Series BF - Incubators Classic.Line with forced convection |
STAT FAX 3300 Biochemistry Analyzer
Stat Fax® 3300 is designed for the processing of biochemistries, tube method immune assays, and drug assays from human serum, plasma, or urine. A removable flowcell installs in the read well to provide extremely rapid fluid sampling with low carryover. A builtin vacuum pump and an external waste bottle with level sensing are supplied standard. When the Flowcell is removed, the instrument accepts standard 12 mm round tubes as well as 1 cm square cuvettes. The design of the instrument includes many features to minimize operator error, such as stable factory calibration, automatic zeroing, complete operator prompting, detailed labeling, pre-programmed calculations, visual and audible
feedback, flags and error messages, minimal maintenance requirements. Test parameters, and standard curves are stored in memory for later recall. The Stat Fax® 3300 will store up to 120 tests in memory to be recalled for later use and allows for creation of Levey-Jennings plots for QC. In addition, it will store 512 Patient Results, 512 Control Results, 20 Patients on Worklist, and 15 tests per patient.
SPECIFICATIONS: |
|
Photometric |
|
Linear Measurement Range: |
0.0 to 3.5 (flow-cell mode) |
|
|
Photometric Accuracy: |
+/- (1% +/- 0.010) 0.0 through 1.5 ABS |
+/- (2% +/- 0.010) 1.5 through 3.0 ABS |
|
|
|
Stability: |
Drift of no more than 0.005A in 8 |
hours/bichromatic |
|
|
|
Light Source: |
Tungsten Halogen, 10 Watt, with |
automatic lamp saver |
|
|
|
Standard Wavelengths: |
340, 405, 505, 545, 580, and 630nm |
alternate filters available from 330 to |
|
750nm; an eight position filter wheel is optional |
|
|
|
Filter Type: |
IAD hardcoat interference, 10nm half |
Bandpass |
|
|
|
Tube Size: |
12mm round is standard |
|
|
Minimum Sample Volume: |
1mL for 12mm round tube |
250uL for flowcell |
|
|
|
Display: |
240x128 Graphic LCD w/ Backlight |
|
|
Printer: |
Thermal dot matrix with graphic capability |
Power Requirements: |
Auto-Switching Power Supply |
|
|
Voltage source: |
90 – 264 VAC |
|
|
Certifications: |
CE |
|
|
Speed: |
Reads, calculates and prints results, 3 |
seconds per tube |
|
|
|
Calculation Modes: |
Factor, Single Standard, Point-to-Point, |
Regression, Index Mode |
|
|
|
Test Storage: |
Stores 120 tests. Stores all parameters |
including wavelengths, calculations, unit |
|
codes, linear and normal ranges rate |
|
timing, standard values, test names, and |
|
previous standard curve. |
|
|
|
Dimensions: |
40cm (L) x 37 cm (W) x 14 cm (H) lid |
closed (30 cm lid opened), 14 lbs (6.4 kg) |
Bead sample pack with 8 types of beads for homogenizing soft tissues: 0.5 and 1.0 mm glass beads (GB05, GB10), 0.5, 1.0, and 2.0 mm zirconium silicate beads (ZRSB05, ZRSB10, and ZRSB20), and 0.5, 1.0, and 2.0 mm zirconium oxide beads (ZROB05, ZROB10, and ZROB20). 10 mL of each.