S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
PCR/qPCR
MIDSCI can supply almost every needed product for PCR/qPCR: tubes, plates, strips, caps, taq, Mastermixes, dNPTs, dye and probe for qPCR, sealing film and much more. If you are looking for any of these things, we can match almost all needs to all cyclers. If you don’t find it easily contact us at tech@midsci.com and we will find it for you.
96 or 384 we have it. Non-Skirted, semi-skirted or full skirted, we have it. 0.1, 0.2, or 0.5 mL we have it. A1, A12, H12, A24, P24 cuts, we have them. Sybr© Green or probe alternative, we have it.
Pro Tip: Colored plastics do not have any impact on DNA amplification. But when setting up qPCR it is often recommended to use white plastics. This will limit or prevent fluorescence refraction. Light refraction can minimize sensitivity and consistency.
Pro Tip 2: If you are seeing inconsistencies in PCR/qPCR try PR1MA Pipette Tips. This will help optimize and reduce variance in the reactions. Simple test, see the residual liquid left in tips? This means some of the taq, dNTPs, sample, etc is left in the tip. PR1MA tips help reduce that significantly and improve your consistency.
Pro Tip 3: Seeing evaporation in the outer wells of a PCR/qPCR plate? Sometimes it’s the plate, sometimes it the seal, and sometimes it’s the cycler. Call us we have solutions.
ig-Fusion Cloning Kit
Intact Genomics propriety ig-Fusion cloning technology is a simple, rapid and highly efficient cloning kit which allows to directly clone any PCR product(s) to any linearized expression vector at any site. The PCR fragments can be generated by Intact Genomics high fidelity Pfu DNA polymerase or other high-fidelity DNA polymerases, with primers having 15 to 18 bases of homology at their linear ends to where the product need to fuse. The linearized vector can be generated by PCR or restriction enzymes. The kit is so robust that multiple DNA fragments can be assembled simultaneously and cloned into one construct in a single reaction step within short times (usually 10-30 min) with more than 95% cloning efficiency.
Benefits
- Clone any insert at any site within any vector
- Restriction enzyme and phosphatase free system
- Joining multiple large fragments at once
- Precise insertion at a desired orientation
- Rapid and high efficiency with > 95% positive clones
Quality Control
Quality control is performed following the production of each new lot of product to ensure that it meets the quality standards and specifications designated for the product. Each lot is repeatedly compared side-by-side with leading competitors to ensure our products outperform the competitor before product launching.
Contents & Storage
- 5x ig-Fusion enzyme premix: -20 °C
- 2x PCR premix: -20 °C
- High efficiency competent cells: -80 °C
- Recovery medium:4 °C or -20 °C
Protocol
1. Linearize the vector by restriction enzyme digestion or inverse PCR and purify the product with spin column.
2. Design PCR primers for the gene of interest with 15 to 20 bp at 5'-extensions that are complementary to the ends of the linearized vector.
3. Amplify the gene of interest with Intact Genomics 2x PCR premix or any other high-fidelity DNA polymerase. Run the PCR product on an agarose gel to determine the integrity of the PCR product.
4. Purify the PCR product with spin column.
5. Set up the ig-Fusion cloning reaction as follows: Insert and vector molar ratio 3:1 produce the highest number of colonies.
Linearized vector |
x µl (50-100 ng) |
Insert |
x µl (50-100 ng) |
5x ig-Fusion enzyme premix |
2.0 µl |
H2O up to |
10.0 µl |
6. Mix the reaction mixture thoroughly.
7. Incubate the reaction mixture at 50 °C for 10-30 min, then place on ice. Number of colonies depend on the incubation time, insert size and number of inserts need to clone.
8. Use 2.0 µl of the reaction mixture and transform into high efficiency ig 10B chemical or electroporation competent cells (included). To get the maximum number of colonies, we recommend to use ig 10B electrocompetent cells (Cat # 1212).
ENDURO™ Semi Dry Blotter
- Western, Southern, and Northern Blots
- Rapid transfer times
- Uniform head dispersion
- Variable gel thickness
- Minimal buffer volume
The ENDURO™ Semi-Dry Blotter provides great flexibility in a lab since it can be used for all types of blotting: Western, Southern, and Northern. Blotting with the ENDURO™ Semi Dry Blotter typically can be done in 15 to 30 minutes making it a fast and easy way to do all your blotting applications. Set up procedures are easy and economical with little buffer needed. The screw down lid adjusts to varying gel thicknesses and sizes while the platinum coated electrodes provide uniform pressure ensuring even transfers. To provide your lab with total blotting solutions use with our ENDURO™ 250V, 3000mA high current power supply.
Specifications
|
Dimensions |
32.5
x 25 x 5.5 cm | 12.8 x 9.8 x 2.2 in |
|
Buffer Volume |
20 mL |
|
Sample Capacity |
4
Blots: 8 x 8.5 cm | 2 Blots: 16 x 8.5 cm | 1 Blot: 16 x 17.5 cm |
Semi-Dry Blotting Systems, 10cm x 10cm
Choose Galileo Insight™ semi-dry sytems for rapid and efficient molecular transfer.
- This unique, new design for the Life Science Laboratory allows crosslinking
and hybridization at one location - Hybridizer and Crosslinker portions of the HL-2000 operate independently of each other
- The Crosslinker is also available as a stand-alone unit
- Temperature control (ambient to 99.9°C)
- Variable speed control (10 to 18 RPM) enabling consistent saturation of samples, whether it be for washing or hybridizing
- Large LED display
- Stainless steel internal construction
- Multiple bottle sizes, arrangements and off-set bottle positions (three bottle sizes available)
- Optional rocker plate
In addition to the hybridization oven features mentioned above, the Crosslinker features: - Preset and manual controls for ultraviolet or time exposures
- Preset exposure delivers 120,000 microjoules or five minutes of exposure
- Shortwave 254nm, 8 watt, ultraviolet tubes
- Microprocessor measures and controls UV output, ensuring maximum energy efficiency
- Large LED display continuously displays time or energy settings
- Tactile membrane switch keypad
- Window on the door allows viewing of the process yet blocks out the UV radiation
- Dimensions: 17.5W x 24H x 15D in. (445 x 610 x 381 mm)
- 1 year warranty
Specification
|
|||||||||||||||||||||||||||||||||||||||
- Small footprint for benchtop use
- Preset and manual controls for ultraviolet or time exposures. Preset exposure delivers 120,000 microjoules or five minutes of exposure
- Microprocessor measures and control UV output, ensuring maximum energy efficiency
- Large LED display and touch panel which displays time or energy settings
- Window on the door allows viewing of the process yet blocks out the UV radiation
- Select from models with 302nm midrange UV, 365nm longwave UV or 254nm shortwave UV Interior: 12 deep x 10 wide x 5 high inches (305 x 254 x 127mm)
- Overhead UV supplies uniform UV
- Shortwave UV model is available with choice of door (CL-1000) or drawer (CX-2000) styles
- Built-in UV sensor is calibrated at the UVP factory to ensure accuracy and reliability
- Crosslinking for attaching nucleic acids to a membrane takes seconds as compared to oven baking
CL-1000 Dimensions: Exterior: 13.7 deep x 15.6 wide x 8.75 high inches (248 x 396 x 222mm)
CX-2000 Dimensions:
Exterior: 17.5"W x 15"D x 9.75"H (445 x 381 x 248mm)
Interior: 11.4"W x 11.3"D x 3.6"H (290 x 287 x 91mm)
Depth of sample tray 11.25 Width of sample tray 11.5
Sample surface to lamp approximately 3.5 in. (89mm)
1 year warranty
|
||||||||||||||||||||||||
- Lamps are lightweight.
- Models available include shortwave, longwave UV or a combination shortwave/longwave version
- Combination version comes with a snap-on wavelength selector for switching between wavelengths
- Use these lamps with the J-129 Lamp Stand (pictured) or the C-10 Cabinet
- 1 year warranty
Handheld Lamp Dimensions:
14.9"L x 3.2"W x 2.5"H
Lamp Stand Dimensions: 9.5"H x 13"L
Shortwave XX Series Lamps use ultraviolet radiation as a reliable and effective tool for sterilization and sanitation applications in hospitals, laboratories, pharmaceutical companies, and clinics. Work surfaces and equipment can become contaminated with bacteria which may be passed through the air or by hand infecting research projects and workers. In addition to bacteria, yeast, mold spores, germs, and viruses may also be present. Shortwave XX Series UV Lamps can kill up to 99% of these organisms. Decontaminate work surfaces with UV prior to PCR to reduce air-borne contamination during DNA sequencing. UV sterilization is particularly useful for temperature sensitive applications due to low operating lamp temperatures.
Shortwave Lamps can be used in an upward facing position for purifying the air or in a downward position for sanitizing work surfaces. Hanging the lamp (brackets provided) reduces the space required on laboratory benchtops. Longwave UV Bulbs (365nm) also available for all models. 1 year warranty
Dimensions
XX-15: 19.75"L x 6"W x 4.25"H
XX-20: 24"L x 6"W x 4.25"H
XX-40: 49.6"L x 6"W x 4.25"H
Exposure Stand: 20"L x 6"W x 13"H
Large Tank Blotter with two cassettes, 20 x 20cm
- Designed to optimally transfer very large and difficult proteins.
- Reproducible transfer results thanks to the plate electrodes made
- of platinum-plated titanium (anode) and stainless steel (cathode).
- Efficient cooling system: Water circulation system with alumina
- ceramic wall located at the chamber base for effective heat
- removal.
- Safety lid: asymmetrical configuration of electrical contacts
- prevents mismatching of electrodes.
UltraSlim® LED Illuminator
- Safer to use that standard UV transillumiators
- NO UV hazard to skin and eyes.
- NO DNA damage inherent to UV - No worries when cutting out bands for elution.
- Easy for use and gel cutting
- NO need to wear amber glasses.
- The THINNEST blue LED illuminator in the world.
- Strong blue LED for excitation.
- Uniform: <10% coefficient of variance (CV) in the central viewing area.
- Compact and Light: 30 mm in height
- Wide applications other than DNA/RNA gel visualization, such as fluorescent proteins.
- Sensitive for a wide range of fluorphores: DNA SafeStain, GelGreen, GelRed, EthBr, SYBR® Safe, SYBR Gold, SYBR Green I® & II, SYPRO® Rudy, SYPRO® Orange, Coomassie Fluor Orange stains, and Lumitein Protein Gel Stain.
The UltraSlim® LED Illuminator is designed for viewing stained gels on the laboratory bench, or within gel documentation systems. Safer lighting from the LED source inside the instrument produces blue light with a narrow emission peak centered at approximately 470 nm, which is more effective for the excitation of most nucleic acid and protein stains. Viewing surface is 120mm x 70mm.
Semi-Dry Blotting Systems, 20cm x 20cm
The larger format 2020 system is ideal for transfer of larger gels or simultaneous transfer of multiple smaller gels. System is supplied complete with power leads and a sample pack of our ultra-pure cotton fiber filter paper.