Heathrow Scientific® Lab Dial Thermometers
Accurate temperature measurement.
Heathrow Scientific® Lab Dial Thermometers are designed for precision and durability in laboratory and industrial applications. Featuring an 8 In. stainless steel stem, a large glass dial face, and a secure attachment clip, this thermometer ensures reliable temperature readings across a wide range of scales.
Ideal for food and beverage quality control, general laboratory use, and asphalt/concrete testing, this thermometer combines robust construction with ease of use. Choose from multiple temperature scales to meet your specific requirements.
Main Attributes
- 8 In. stainless steel stem for durability and accuracy
- Large glass dial face for easy reading
- Includes attachment clip for secure placement
- Available in a wide range of temperature scales
Specifications
| Item # | Temperature Range | Subdivisions | Accuracy | Dial Diameter |
| 82110 | -10 to 110°C | 1°C | ±1°F | 1.75 In. |
| 82125 | 25 to 125°F | 1°F | ±1°C | 1.75 In. |
| 82220 | 0 to 220°F | 2°F | ±2°F | 1.75 In. |
| 82550 | 50 to 550°F | 5°F | ±5°F | 1.75 In. |
| 82550DG | 50 to 550°F / 10 to 290°C | 2.5°F / 5°C | ±2.5°F / ±5°C | 2 In. |
Heathrow Scientific® Pocket Dial Thermometers
Compact and accurate.
Heathrow Scientific® Pocket Dial Thermometers are the perfect solution for on-the-go temperature measurement in food and beverage quality control, general laboratory use, and asphalt/concrete testing. Its compact design features a small stem and dial face that fit easily into a shirt pocket or holder, making it convenient for field and lab work.
Each thermometer includes a protective stem cover for safe transport and storage. Built with a durable polycarbonate lens, it withstands frequent use and harsh conditions. Available in a wide range of temperature scales to meet diverse application needs.
Main Attributes
- Small stem fits into cover for secure pocket attachment
- Compact design for portability and ease of use
- Durable polycarbonate lens for long-lasting performance
- Includes stem cover for safe transport and storage
- Wide variety of temperature ranges available
Specifications
| Item # | Temp. Range | Temp. Resolution | Dial Diameter | Stem Length | Stem Cover |
| 81070 | -40 to 70°C | 1°C | 1 In. | 25 mm | 5 In. | 127 mm | Yes |
| 81110 | -10 to 110°C | 1°C | 1 In. | 25 mm | 5 In. | 127 mm | Yes |
| 81125 | 25 to 125°F | 1°F | 1 In. | 25 mm | 5 In. | 127 mm | Yes |
| 81550 | 50 to 550°F | 5°F | 1 In. | 25 mm | 5 In. | 127 mm | Yes |
Heathrow Scientific® Hydrometer Cases
Durable PVC protection for your hydrometers.
Keep your hydrometer safe and secure with Heathrow Scientific® Hydrometer Cases. Crafted from high-quality polyvinyl chloride (PVC), these protective cases are designed to prevent damage during storage or transport. Each case features a foam or felt padded insert, plus a padded bottom and cap for extra cushioning. Ideal for laboratories, breweries, and any environment where hydrometers are used, these cases ensure long-lasting protection and convenience when your hydrometer is not in use.
Specifications
| Item # | Material | Style | Length |
| 66CS-8 | PVC | Standard | 8.5 In. | 216 mm |
| 66CS-8F | PVC | Short | 8.5 In. | 216 mm |
| 66CS-13 | PVC | Standard | 13.5 In. | 343 mm |
| 66CS-13J | PVC | Wide Body | 13.5 In. | 343 mm |
| 66CS-16 | PVC | Standard | 16.5 In. | 420 mm |
Enterprise 350 pH Meter
- Simultaneous pH and temperature display
- Storage of up to 32 results
- Automatic or manual calibration 500 hours battery life
- Application specific electrodes and consumables
The 350271 is a general purpose portable pH meter offering 1 or 2 point pH calibration and automatic buffer recognition with manual override. It simultaneously displays both the temperature compensated pH readings and the manually set temperature.
Specifications
| 350271 | 370271 | |
| pH range | -2 to 16 | -2 to 16 |
| pH resolution | 0.01 | 0.01 |
| pH accuracy | ± 0.02 | ± .02 |
| Automatic buffer recognition | 4, 7, 9.22, 10 (with manual override) | 4, 7, 9.22, 10 (with manual override) |
| Calibration | User selectable 1 or 2 point | User selectable 1 or 2 point |
| mV range | ----- | ± 1999 mV (absolute or relative) |
| mV resolution | ----- | 1 mV |
| mV accuracy | ----- | ± 1 mV |
| Temperature range | ---- | -10 to 105°C |
| Temperature resolution | ----- | 0.1°C |
| Temperature accuracy | ---- | ± 0.5°C |
| Manual temperature range | 0 to 100 ° C | 0 to 100°C |
| Connector | BNC | BNC |
| Power | 2 AA batteries | 2 AA batteries |
| Battery life | 500 hours (typical) | 500 hours (typical) |
| Size (l X w x d) | 175 x 75 x 35 mm | 175 x 75 x 35 mm |
| Weight | 250 g | 250 g |
Jenway pH Meter 3510
The 3510 is a versatile, simple to use pH, mV and temperature meter that is ideal for routine analysis. With up to three decimal place resolution and a choice of up to three calibration points the 3510 provides the user with added flexibility where future demands for enhanced performance may be required. A choice of pH calibration buffers to DIN, JIS and NIST standards can be used for automatic calibration, as well as manually entered buffer values.
Specifications include:
- Simultaneous readout of pH and temperature
- pH resolution to 3 decimal places
- 1, 2 or 3 point calibration
- Automatic or manual buffer selection
- Storage of up to 32 results
- RS232 connection to printer or PC via optional DataWay PC software
- Warranty: 2 years
3510 pH/mV meter supplied with glass combination pH electrode, electrode stand and holder, ATC probe, BNC shorting plug, pH 4, 7 and 10 buffers and US power supply
Specifications:
| Parameter | 3510 |
| pH range | -2.000 to 19.999 |
| pH resolution | 0.001 / 0.01 / 0.1 |
| pH accuracy | ± 0.003 |
| Calibration | User selectable 1, 2 or 3 point |
| Automatic buffer recognition | Jenway (2.00, 4.00, 7.00, 9.20 and 10.00), DIN, NIST, JIS |
| mV range | ± 1999.9 mV |
| mV resolution | 0.1 / 1 mV |
| mV accuracy | ± 0.2 mV |
| Temperature range | -10 to 105°C |
| Temperature resolution | 0.1°C |
| Temperature accuracy | ± 0.5°C |
| ATC range | 0 to 100°C |
| Alarm points | - |
| GLP | - |
| Outputs | Analogue and RS232 |
| Connector | BNC |
| Power | 9VAC (adaptor included) |
| Size (L x W x D) | 210 x 250 x 55 mm / 8.3 x 10 x 2.2 in. |
| Weight | 850g / 2 lbs. |
Chromate Microplate Reader
- Compact and economical
- Reads absorbances of 96-wells in under 10 seconds
- Streamlined design to fit any lab bench
- Ready to "plug and play" with your PC
Specifications:
| Photometric: | |
| Linear Measurement Range: | -0.20 to 4.0 absorbance units (A) |
| Photometric Accuracy: | ±1% |
| Stability: | Drift of no more than 0.005A in 8 hours |
| Light Source: | Remote halogen lamp source with lamp saver feature |
| Wavelengths: | Standard: 405, 450, 492, and 630nm |
| Filter options from 405nm to 700nm | |
| Filter Type: | IAD hardcoat interference, 10nm half bandpass |
| Vessel: | Standard 96-well microtiter plates, or strip trays |
| Electronic: | |
| Power Requirements: | 115V or 230V, 50-60Hz (auto-sensing) |
| PC Connection | USB port |
| Speed | Reads absorbances of 96 wells in about 8 seconds |
| Software: | |
| Calculation Modes: | Single-point calibration, point-to-point curve fit, polynomial regression, linear and sigmoidal regression (log & linear), cutoff absorbance, multipoint % absorbance |
| Additional Features: | User-programmable open system, selectable plate formatting, alphanumeric test naming, automatic interpretation options, duplicate well options, curve plotting and editing, flags and error messages |
| Dimensions: | 7.25 x 7.25 x 16.5 inches |
| Weight: | 10 lbs. |
| Warranty | 1 year |
This Item has been discontinued.
See the Azure Biosystems Cielo qPCR System instead!
MyGo Pro ESR
The MyGo Pro real-time PCR instrument provides unmatched performance in a convenient format. Novel Full Spectrum Optics deliver 120 optical channels of fluorescence data from every tube in parallel, with no moving parts, for reliable multiplex PCR.
Precision And Performance
The MyGo Pro demonstrates superior intra-run and inter-run analytical precision in DNA quantification and melting point analysis.
Users can now address biological phenomena with subtle effects on gene expression, or pathogen levels, for example discriminating 10% differences in transcript concentrations.
For users performing HRM-based analysis of genetic variants, the combination of thermal control, optical data quality, and HRM data analysis of the MyGo Pro system provides compelling functionality. The system can discriminate all classes of SNP, including Class 4 SNPs via HRM.
Multiplex With Full Spectrum Optics
Novel Full Spectrum Optics provide 120 channels of wavelength-dependent optical data from every well every time. No other qPCR system offers this number of optical channels.
Full Spectrum Optics, combined with advanced matrix deconvolution technology, enable the simultaneous analysis of at least 7 different targets in a single reaction, each monitored with a different color of fluorescent label.
The MyGo Pro comes pre-calibrated for 20 different fluorescent labels, and the software enables users to use any dye with an emission maximum between 510nm and 750nm. No other qPCR system provides the user with this level of flexibility.
Easy Analysis
The MyGo Pro system comes with easy-to-use software, and robust, high-performance algorithms provide accurate results from complex data.
Automated analysis of complex HRM data makes this powerful technique more accessible to non-experts and minimizes operator-dependent variability in data analysis.
Automated report generation makes life easier for service providers, and users operating within GLP quality systems.
Reliability
The MyGo Pro has been designed to last, with very few moving parts, made and tested to exacting standards. The result is a highly reliable instrument, which comes with the option of a 5-year extended warranty.
Speed
With heating rates of 5°C per second and cooling rates of 4°C per second the MyGo Pro is one of the fastest systems available. No other system matches this speed with convenient-to-use disposables. The system demonstrates excellent quantitative precision and speed, with 45 cycles of PCR in 33 minutes. Typical qPCR systems take much longer than this to deliver results.
Compatibility
The MyGo Pro software can be installed on Mac OS X, Windows, and Linux operating systems. Use your computer and your choice of operating system.
Connectivity
The MyGo Pro software does not require a dedicated computer, so users do not need to find the space or money, for an additional computer to run the system. In addition, the software enables the user to control multiple instruments, and simultaneously analyze multiple runs, with one computer.
Accuris SmartReader™ UV-Vis Microplate Reader
The Accuris SmartReader™ UV-Vis Microplate Reader (model
MR9610) has been designed with ease-of-use and fast results in mind. This
instrument brings extensive capabilities to the lab bench and is designed for
the busy lab with multiple users. The large touch screen command center is
extremely user-friendly and allows for fast set up of new protocols, as well as
modifying and running existing protocols.
- Intuitive, 10-inch color
touch screen control panel
- Accepts both 96 & 384-well
plates
- Monochromator-based
system
• No filters required
• Wavelength range from 200 to 1000 nm - Stand-alone design
• No PC or special software required
• USB port for flash drive data transfer
Monochromator technology … no filters needed
The monochromator-based optical system allows for precise
selection of wavelengths from 200nm to 1000nm, with no filters required. This
range makes the SmartReader UV-Vis™ useful not only for typical ELISA ,
Bradford Lowry, and turbidity assays but also for more advanced applications
such as quantitation of nucleic acids and proteins. The SmartReader™ UV-Vis can
be set for Endpoint, Kinetic and Spectral Scanning assays.
High Throughput Capability
The MR9610 is designed for efficient processing of multiple
samples and
accepts standard 96 well plates as well as 384 well plates for high density
screening. The plate layout interface allows for a quick and intuitive setup of
a plate well’s contents. Users can highlight and label multiple wells to save
time. The display shows a graphical representation of the plate. Users can
label each well as required for: “known standard”, “unknown sample”, “blank
well” , “QC Control well”, “positive control”, “negative control”, and “empty”.
Optimized results with plate shaking and incubation
Controllable plate shaking and incubation allow for optimization of assay results. The shaking speed can be controlled at different intensities with options for timed and pulsed shaking before a reading, or in between readings when performing a kinetic assay. The linear motion efficiently and uniformly mixes all samples in both 96 and 384 well plates. Temperature can be controlled from ambient +5C up to 45C, allowing for the processing of enzyme kinetics, and bacterial growth assays.”
SmartDrop™ Accessory Plate
Absorbance measurements of exceptionally small volumes
(<0.5ul) can be achieved using the SmartDrop™ Accessory Plate. The
SmartDrop™ plate accommodates up to 16 samples and is ideal for checking
nucleic acid concentrations and purity for Next Gen Sequencing, or protein
concentrations.
SmartReader™ UV-Vis Microplate Reader Specifications
|
Model |
Accuris SmartReader™ UV-Vis |
|
Plates Accepted |
96-well and
384-well flat bottom |
|
Display |
10-inch color
touch screen |
|
Controls |
Touch screen
and mouse |
|
Light Source |
Xenon Flash
Lamp |
|
Wavelength range |
200-1000nm |
|
Wavelength Precision |
± 2 nm |
|
Wavelength Accuracy |
± 2 nm |
|
Wavelength selection |
Monochromator |
|
Read-out range |
0 – 4.0 OD |
|
Detector |
Dual silicon photoelectric
detectors for measurement and reference |
|
Linearity @ 450nm |
R2 ≥
0.999, [0.0 – 3.0] |
|
Accuracy @ 450nm |
1.0% + 0.003
Abs (0 – 2.0] |
|
Precision@450nm |
CV < 0.5% or
SD<0.003 (Precision mode); CV < 1.0% (Fast mode) |
|
Stability@450nm |
< 0.005A ,
(0.0 – 2.0] |
|
Measurement speed |
96 well
plate: <6 seconds (fast mode); <25 seconds (precision mode) |
|
Plate shaking |
Linear; three
levels of shaking speed |
|
Incubator |
From ambient +
5°C to 45°C |
|
Temperature Uniformity |
± 0.5°C @ 37°C |
|
Storage |
16G memory,
more than 10,000 test records can be stored |
|
Connection Ports |
3 USB ports,
for PC, printer and USB-flash drive |
|
Power supply |
DC24V
6.5A |
|
Dimensions (WxDxH) |
300 x 500 x 260mm |
11.8 x 19.7 x 10.25 inches |
|
Weight |
15.5kg | 34 Lbs |
We are no longer distributing Cerillo Stratus Plate Readers.
For more information or to explore alternative options, please contact us or visit here.
Available units while supplies last.
Cerillo Stratus Plate Readers
A plate reader designed by anaerobic researchers, for anaerobic researchers.
The Stratus plate reader is small enough to fit in the palm of your hand and allows for measurement collection in small spaces, on shared or modular benchtops, and even in restrictive environments, like anaerobic or microaerophilic chambers. Its uniquely simple, standalone interface and on-board data storage allow it to be placed anywhere, with or without a computer.
- Withstands heating, shaking, and anaerobic conditions
- Small footprint allows for use (and storage) in the smallest of spaces
- Can be used with or without a computer
- Affordable!
The Stratus plate reader has new and improved capabilities to optimize
flexibility for sample data collection in multiple standard plate formats
to serve the wide-ranging needs of scientific researchers.
- Continuous real-time measurements of optical density
- Available in Standard 600 nm or customized wavelength
- Standard 6-, 12-, 24-, and 96-well plates
- Small footprint and stackable
- No moving parts; minimal maintenance
- Functional in a broad range of environments
- User-friendly software
Applications Include
- Bacterial Growth/Density
- Protein Quantification
- Enzyme-linked Immunosorbent Assay
- Reporter Gene Assays
- Cell Proliferation
- Cytotoxicity/Apoptosis
Plate Reader Product Description:
The Stratus plate reader is small enough to fit in the palm of your hand
and allows for measurement collection in small spaces, on shared or modular
benchtops, and even in restrictive environments, like anaerobic or
microaerophilic chambers and incubators.
Its uniquely simple, standalone interface and on-board data storage allow
it to be placed anywhere, with or without a computer.
Overall, the Stratus exploits the best of modern technology to reduce labor
and allow you to spend your efforts where they matter most. Cerillo has
been uncompromising in the Stratus's design and performance; all that's
left is for you to try it yourself.
|
Wavelength |
600nm
(Note: Customized wavelengths available)
|
|
Dimensions |
Width: 14.4 cm (5.7 in.) Depth: 13.0 cm (5.1 in.) Height: 6.8 cm (2.7 in.)
|
|
Weight |
580 g (20.5 oz.) |
|
Ambient Atmospheric Tolerance |
Temperature: 0° to 50°C (32° to 122°F) Humidity: 0 to 99% O2 concentration: Any CO2 concentration: Any
|
|
Sterilization Techniques |
Chemical surface treatment
(recommended)
EtO Gas Sterlization
|
|
Plate Formats |
96 -well, 24-well, 12-well, 6-well, |
|
Temporal Resolution |
Up to 30 plate reads per hour (user-defined)
|
|
OD Resolution |
±0.005 at OD600 |
|
Data Storage |
microSD-compatible memory slot, |
|
Power Supply |
5V, 500 mA USB Supply |
Adapter
The Cerillo Stratus adapter is precision-manufactured out of a high-quality, durable material designed to stand up to rigorous use in the lab. It allows a Stratus be secured to a universal shaker plate via screws, and also features high-friction silicone strips and powerful neodymium magnets. The adapter features a plate-size extrusion allowing it to fit securely to small shakers designed for a microplate.
Adapter Product Description
The adapter is designed for use with orbital shakers, microplate shakers, and shaking incubators. Unique attachment method allows for either magnetic attachment, screw attachment, or via silicone rubber footing on rubber mats. The adapter is reusable.
Additional Adapter Information
- Material: Thermoset Epoxy Resin
- Screws: #10-24 × 5/8 inch (15.875 mm) flat Philips head for aluminum, captive mounting screws
- Ratings up to 500 RPM in beta test cases.
- Item Weight: 125 g (4.5 oz)
SmartReader™ MultiMode Plate Reader
- Intuitive, 10-inch color touch screen
- Stand-alone system with optional PC software (FDA CFR Part 11)
- Monochromator-based system for UV through visible absorbance
- Filter module system for fluorescence assays
- Advanced PMT detector for luminescence assays
- Optional automatic injection modules for flash luminescence
- ELISA Assays
- Colorimetrics Assays (Bradford, Lowry, etc.)
- Enzyme Kinetics
- Spectral Scanning
- DNA & RNA Analysis
- …and more
STAT FAX 4200 Microplate Reader
The Stat Fax 4200 Microplate Reader is a compact, microprocessor-controlled, multi-purpose
photometer system designed to read and calculate the results of assays, which are read in 96
well microtiter plates or strip trays. The microplate reader may be used for in-vitro diagnostics. It is a user-programmable open system with selectable plate formatting, alphanumeric test naming, automatic interpretation options, duplicate well options, curve plotting and editing, flags and error messages from which the user can create a menu of pre-programmed assays for instant recall. This instrument is intended to be used as a stand-alone instrument without a PC but it has a connection in the event a user wishes to download results.
Stat Fax 4200 reads monochromatically (optional) or bichromatically (optional) and has two
models:
- Four-filter model (405, 450, 492, and 630 nm)
- Six-filter VIS model (405, 450, 492, 545, 600, and 630 nm)
Substitute filters in the range of 405 nm – 750 nm are available on special order
models.
Stat Fax 4200 accepts all standard microplates. Trays containing microstrips may also be read
whether they are 12 wells in length, 8 wells or even partial strips.
The software allows the operator to create, edit and store assays. Standard
curves are also stored in this memory. Test protocols remain stored until either changed or
deleted by the user.
TheStat Fax 4200’s optical system provides an economical and low maintenance design which reads 8 wells simultaneously. A 96 well plate can be read and printed in the absorbance mode in approximately ten seconds. Light from a lamp installed in a sealed light-tight compartment is filtered using a rotating filter wheel. The filtered light is then divided into 8 channels using a fiber optic bundle. The plate carrier precisely positions each row of 8 wells into the optical path for reading. Light passing through the 8 wells is directed to 8 photo-detectors. The filter wheel moves to a second position to read the 8 wells at a second wavelength. Using bichromatic differential absorbance values corrects for optical imperfections in the plastic wells and removes the effects of meniscus and turbidity.
Specifications: |
|
Photometric |
|
Linear Measurement Range: |
0.0 to 4.0 Absorbance Units (A) |
Photometric Accuracy: |
+/- (1% +/- 0.010) 0.0 through 1.5 ABS |
+/- (2% +/- 0.010) 1.5 through 3.0 ABS |
|
Stability: |
Drift of no more than 0.005A in 8 hours |
Light Source: |
Halogen lamp with lamp saver feature |
Standard Wavelengths: |
405, 450, 492, and 630nm. 6-filter: 405, |
450, 492, 545, 600, and 630nm. Filter |
|
options from 405nm to 700nm |
|
Filter Type: |
IAD hardcoat interference, 10nm half bandpass |
Vessel: |
Standard 96-well microplates, or strip trays |
Electronic |
|
Display: |
Interactive touch screen 5.7” (14.5cm) |
LCD, color graphic display |
|
Printer: |
Thermal 64 characters per line, plus graphics |
Power Requirements: |
100-240V AC, 1.2A, 50-60Hz (universal |
input, auto sensing) |
|
Interface: |
USB mouse; USB port used for thumb |
drive interface for firmware updates |
|
(mouse not included; thumb drive not |
|
Speed: |
Reads absorbance of 96 wells in about |
10 seconds |
|
Calculation Modes: |
Factor, Single Standard, Point-to-Point, |
Regression, Cubic Spline, Cut Off Mode |
|
Test Storage: |
Stores 120 tests; stores all parameters |
including wavelengths, calculations, unit |
|
codes, linear and normal ranges, |
|
standard values, test names, and |
|
previous standard curve |
|
Dimensions: |
Approximately 13.5”Wx17”Dx8-1/4”H |
(34.3cmx43.2cmx21cm) weight 12 lbs |
|
(5.5kg) | |
STAT FAX 3300 Biochemistry Analyzer
Stat Fax® 3300 is designed for the processing of biochemistries, tube method immune assays, and drug assays from human serum, plasma, or urine. A removable flowcell installs in the read well to provide extremely rapid fluid sampling with low carryover. A builtin vacuum pump and an external waste bottle with level sensing are supplied standard. When the Flowcell is removed, the instrument accepts standard 12 mm round tubes as well as 1 cm square cuvettes. The design of the instrument includes many features to minimize operator error, such as stable factory calibration, automatic zeroing, complete operator prompting, detailed labeling, pre-programmed calculations, visual and audible
feedback, flags and error messages, minimal maintenance requirements. Test parameters, and standard curves are stored in memory for later recall. The Stat Fax® 3300 will store up to 120 tests in memory to be recalled for later use and allows for creation of Levey-Jennings plots for QC. In addition, it will store 512 Patient Results, 512 Control Results, 20 Patients on Worklist, and 15 tests per patient.
SPECIFICATIONS: |
|
Photometric |
|
Linear Measurement Range: |
0.0 to 3.5 (flow-cell mode) |
|
|
Photometric Accuracy: |
+/- (1% +/- 0.010) 0.0 through 1.5 ABS |
+/- (2% +/- 0.010) 1.5 through 3.0 ABS |
|
|
|
Stability: |
Drift of no more than 0.005A in 8 |
hours/bichromatic |
|
|
|
Light Source: |
Tungsten Halogen, 10 Watt, with |
automatic lamp saver |
|
|
|
Standard Wavelengths: |
340, 405, 505, 545, 580, and 630nm |
alternate filters available from 330 to |
|
750nm; an eight position filter wheel is optional |
|
|
|
Filter Type: |
IAD hardcoat interference, 10nm half |
Bandpass |
|
|
|
Tube Size: |
12mm round is standard |
|
|
Minimum Sample Volume: |
1mL for 12mm round tube |
250uL for flowcell |
|
|
|
Display: |
240x128 Graphic LCD w/ Backlight |
|
|
Printer: |
Thermal dot matrix with graphic capability |
Power Requirements: |
Auto-Switching Power Supply |
|
|
Voltage source: |
90 – 264 VAC |
|
|
Certifications: |
CE |
|
|
Speed: |
Reads, calculates and prints results, 3 |
seconds per tube |
|
|
|
Calculation Modes: |
Factor, Single Standard, Point-to-Point, |
Regression, Index Mode |
|
|
|
Test Storage: |
Stores 120 tests. Stores all parameters |
including wavelengths, calculations, unit |
|
codes, linear and normal ranges rate |
|
timing, standard values, test names, and |
|
previous standard curve. |
|
|
|
Dimensions: |
40cm (L) x 37 cm (W) x 14 cm (H) lid |