S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Hoefer® Mighty Small Transfer Tank
The TE22 Mighty Small Transfer Tank quickly and efficiently transfers proteins and nucleic acids from small gels to nylon, nitrocellulose or PVDF membranes. Maximum Gel Size 9 x 10 cm.
- Transfer as many as four small gels, up to 9 x 10 cm in less than an hour
- Uniform and strong electric field—supports efficient and even transfers
- Color-coded, easy to assemble and load cassettes—ensures proper orientation during transfer
- Superior tank design allows the cassettes to apply equal pressure across the stack - prevents gel distortion
- Built-in ceramic heat exchanger—provides excellent temperature control when used with an external cooling water bath
- Built-in alumina-covered cooling channel provides excellent temperature control with no more than a 5°C temperature increase during a typical run
Hoefer® Mighty Small Transfer Tank Includes
- Lower Chamber with Heat Exchanger, 1/ea
- Safety Lid with High Voltage Leads, 1/ea
- Electrode Panels, 2/pk
- Cassettes, 4/pk
- Foam Sponges, 6 mm thick, 4/pk
- Foam Sponges, 3 mm thick, 8/pk
- Cassette Hook, 1/ea
- Blotter Paper (9 x 10.5 cm), 25 sheets/pk
Hoefer® Mini Electrophoresis and Western Blot Package
Save time and money with a combination package.
- SE260-10A-75 Mighty Small II Mini Deluxe Vertical Unit
- TE22 Mighty Small Mini Transfer Tank
- PS300B 300 V, 500 mA, 90 W Power Supply
Specifications
| Capacity | Up to four 9 x 10 cm gels |
| Max. Power | 100 V, 500 mA, 50 W |
| Max. Temp. | 113ºF | 45°C |
| Indoor Use | 39.2 to 104ºF | 4 to 40°C |
| Humidity | Up to 80% |
| Dims (D x W x H) | 6.50 x 5.51 x 9.45 In. | 16.5 x 14 x 24 cm |
| Weight | 4.441 lb | 2.00 kg |
Proudly made in the USA! Click here for more made in America products!
Hoefer® Standard Transfer Tank
The TE42 Standard Transfer Tank quickly and evenly transfers proteins and nucleic acids from polyacrylamide or agarose gels onto nylon, nitrocellulose, or PVDF membranes. The four slot design of the TE42 enables either cooled or non-cooled protein or nucleic acid transfers. The optional heat exchange module is easily incorporated into the TE42 enabling transfer of up to 2 gels simultaneously. When used without the optional heat exchange module, up to four gels can be transferred at one time.
- Uniform and strong electric field—supports efficient and even transfers
- Color-coded, easy to assemble cassettes—ensures proper orientation during transfer
- Superior tank design allows the cassettes to apply equal pressure across the stack - prevents gel distortion
- Optional TE47 heat exchanger—provides excellent buffer temperature control when used with an external cooling water bath
- Heat exchanger from an SE600 series electrophoresis unit can be substituted for the TE47 heat exchanger.
Hoefer® Standard Transfer Tank Includes
- Lower Chamber, 1/ea
- Safety Lid with High Voltage Leads, 1/ea
- Electrode Panels, 2/pk
- Cassettes, 2/pk
- Foam Sponges, 6 mm thick, 2/pk
- Foam Sponges, 3 mm thick, 4/pk
- Cassette Hook, 1/ea
- Blotter Paper (14.5 x 21.5 cm), 25 sheets/pk
Specifications
| Capacity | Up to four 15 x 21 cm gels (w/out cooling) Up to two 15 x 21 cm gels (w/ cooling) |
| Max. Power | 100 V, 2 A, 200 W |
| Max. Temp. | 113ºF | 45°C |
| Indoor Use | 39.2 to 104ºF | 4 to 40°C |
| Humidity | Up to 80% |
| Dims (D x W x H) | 12.01 x 3.15 x 5.12 In. | 30.5 x 8 x 13 cm |
Proudly made in the USA! Click here for more made in America products!
Hoefer® Standard Transfer Tank with Cooling Chamber
TE62 Standard Transfer Tank with Cooling Chamber quickly and evenly transfers proteins and nucleic acids from polyacrylamide or agarose gels onto nylon, nitrocellulose, or PVDF membranes while providing excellent temperature control.
The TE62 is designed to accept up to four cassettes simultaneously with cooling. Each cassette holds a 15 x 21 cm gel, or as many as four 7 x 10 cm mini gels.
- Uniform and strong electric field—supports efficient and even transfers
- Color-coded, easy to assemble cassettes - ensures proper orientation during transfer
- Superior tank design allows the cassettes to apply equal pressure across the stack - prevents gel distortion
- Built-in ceramic heat exchanger - provides excellent temperature control when used with an external cooling water bath
Hoefer® Standard Transfer Tank with Cooling Chamber Includes
- Lower Chamber with Heat Exchanger, 1/ea
- Safety Lid with High Voltage Leads, 1/ea
- Electrode Panels, 2/pk
- Cassettes, 4/pk
- Foam Sponges, 6 mm thick, 4/pk
- Foam Sponges, 3 mm thick, 8/pk
- Cassette Hook, 1/ea
- Blotter Paper (14.5 x 21.5 cm), 25 sheets/pk
Specifications
| Capacity | Up to four 15 x 21 cm gels Up to sixteen 7 x 10 cm gels |
| Max. Power | 100 V, 2 A, 200 W |
| Max. Temp. | 113ºF | 45°C |
| Indoor Use | 39.2 to 104ºF | 4 to 40°C |
| Humidity | Up to 80% |
| Dims (D x W x H) | 12.60 x 11.02 x 6.50 In. | 32 x 28 x 16.5 cm |
Proudly made in the USA! Click here for more made in America products!
Azure Aqua Transfer Cell
Perform a quick 1 hour transfer or transfer overnight at a lower voltage
Aqua Transfer Cell is used for transferring two mini gels to membranes for Western blotting experiments (wet transfer). The transfer cassettes and electrode core are colored for directionality which makes transferring easy and straightforward.
Includes:
- 2 transfer cassettes
- 6 sponges
- 2 Azure Aqua cooling units
- Tank and upper lid with power cables
- Transfer Electrode Cores
Features
The transfer cassettes and electrode core are colored for directionality, making transferring easy and straightforward.
Chemical reagent compatibility
Keep all components of the Azure Aqua Transfer Cell away from chloroform, arenes (such as methylbenzene benzene), and acetone. Any damage caused by these reagents is not covered by the warranty policy.
Cleaning Instructions
Before using, wash all components with a neutral detergent and rinse well with ultra pure water.
Wash the electrode assembly, transfer cassettes, and buffer tank with a neutral detergent and warm water. Be careful to avoid damaging the platinum electrodes. Use warm water to rinse the sponges, and then rinse all components with distilled or ultra-pure water.
Specifications
| Parameters | Azure Aqua Transfer Cell Specs |
| Number of cassettes | 2 |
| Buffer requirement | 1100 mL |
| Electrode distance | 4 cm |
| Electrode assembly size ( L x W x H) | 17.5 cm x 13.5 cm x 19 cm |
| Transfer time | 60 minutes |
| Cooling | Azure Aqua cooling unit |
| Blotting area | 7.5 cm x 10 cm |
| Buffer volume (with cooling unit) | 650 mL |
| Buffer volume (without cooling unit) | 850 mL |
| Unit dimensions (W x L x H) | 13.5 cm x 17.5 cm x 19 cm |
| Tank buffer volume | 1100 mL |
| Maximum gel size | 7.5 cm x 10 cm |
| Gel capacity | 2 precast or handcast gels |
| Weight | 1.8 lbs |
| Recommended power supply | Azure Aqua Power Supply 600V |
Hoefer® Semi-Dry Transfer Units
Hoefer® Semi-Dry Transfer Units are efficiently designed to use minimal buffer to transfer proteins from polyacrylamide gels onto membranes (either nitrocellulose or PVDF) in less than an hour. They support as many as two layers of gels being transferred simultaneously. The TE70XP has a 14 x 16 cm maximum transfer area, which can handle up to four mini gels using the stacked format. The TE77X and TE77XP have a 21 x 26 cm transfer area for a capacity of up to 12 mini gels at one time.
- Included safety circuit breaker—limits voltage and current from the user's power supply, preventing electrical damage to the transfer unit
- Requires minimal current—does not generate the excessive heat that can dry out the transfer stack and halt transfer or damage transfer units
- Durable iridium oxide and stainless steel electrodes—allow for contamination free, consistent transfer
- Vented electrodes—prevent buildup of bubbles which may impair transfer
- Minimal buffer requirements—reagent cost and preparation time are reduced
- The TE70XP and TE77XP Semi-Dry Transfer Units have an intelligent built-in power supply that prevents the stack from overheating by monitoring the transfer status
All units include
- Molded Base with Platinum-Coated Titanium Anode and High Voltage Leads
- Hinged Lid with Stainless Steel Cathode
TE77X includes
- Blotting Paper (21 x 26 cm), 25/pk
- Porous Cellophane (20 x 35.5 cm), 50/pk
- Mylar® Masks (23 x 27.5 cm), 2/pk
- Hinged Lid with Stainless Steel Cathode, 1/ea
TE70XP includes
- Blotting Paper (14 x 16 cm), 25/pk
- Porous Cellophane (20 x 35.5 cm), 50/pk
- Mylar® Masks (16.5 x 18.5 cm), 2/pk
TE77XP includes
- Blotting Paper (21 x 26 cm), 25/pk
- Porous Cellophane (20 x 35.5 cm), 50/pk
- Mylar® Masks (23 x 27.5 cm), 2/pk
Specifications
| Item # | TE77X | TE70XP | TE77XP |
| Transfer Area | Up to 21 x 26 cm Up to 8.27 x 10.24 In. | Up to 14 x 16 cm Up to 5.51 x 3.60 In. | Up to 21 x 26 cm Up to 8.27 x 10.24 In. |
| Max. Power | 30 V, 500 mA, 15 W | ||
| Max. Temp. | 113ºF | 45°C | ||
| Indoor Use | 39.2 to 104ºF | 4 to 40°C | ||
| Humidity | Up to 80% | ||
| Dims (D x W x H) | 3.54 x 14.96 x 18.11 In. | 9 x 38 x 46 cm | ||