S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Hoefer® Spacers for Dual and Air Cooled Vertical Systems
Gel Spacers for SE400 and SE600 Series Vertical Electrophoresis Systems.
Engineered for consistent gel casting, these precision-machined spacers are made from high-strength, chemically resistant plastics. Available in three lengths (8, 16, and 24 cm) and multiple thicknesses (0.75 mm, 1.0 mm, 1.5 mm) to accommodate various gel formats.
All 1.0 mm spacers are white for quick identification during setup.
Specifications
| Item # | Thickness | Length | Width |
| SE6419-2-75 | 0.030 In. | 0.75 mm | 3.15 In. | 8 cm | 0.79 In. | 2 cm |
| SE6419-2-10 | 0.039 In. | 1 mm | 3.15 In. | 8 cm | 0.79 In. | 2 cm |
| SE6419-2-15 | 0.059 In. | 1.5 mm | 3.15 In. | 8 cm | 0.79 In. | 2 cm |
| SE6119-2-75 | 0.030 In. | 0.75 mm | 6.30 In. | 16 cm | 0.79 In. | 2 cm |
| SE6119-2-10 | 0.039 In. | 1 mm | 6.30 In. | 16 cm | 0.79 In. | 2 cm |
| SE6119-2-15 | 0.059 In. | 1.5 mm | 6.30 In. | 16 cm | 0.79 In. | 2 cm |
| SE6619-2-75 | 0.030 In. | 0.75 mm | 9.45 In. | 24 cm | 0.79 In. | 2 cm |
| SE6619-2-10 | 0.039 In. | 1 mm | 9.45 In. | 24 cm | 0.79 In. | 2 cm |
| SE6619-2-15 | 0.059 In. | 1.5 mm | 9.45 In. | 24 cm | 0.79 In. | 2 cm |
| SE6118-2-10 | 0.039 In. | 1 mm | 6.30 In. | 16 cm | 0.39 In. | 1 cm |
| SE6118-2-15 | 0.059 In. | 1.5 mm | 6.30 In. | 16 cm | 0.39 In. | 1 cm |
Proudly made in the USA! Click here for more made in America products!
Hoefer® T-Spacers for Mini Vertical Systems
Compatible with SE300 MiniVE, SE260, and the SE250 Series Vertical Electrophoresis Systems.
Ensure accurate gel thickness and leak-free casting with precision-milled T-spacers. All spacers are precision-machined from durable plastics for high chemical resistance and optimum tensile strength. These spacers provide consistent alignment and long-term durability for mini vertical systems.
Available in multiple lengths (8 cm and 10.5 cm) and thicknesses (0.75 mm, 1.0 mm, and 1.5 mm) to suit your specific gel requirements.
Specifications
| Item # | Thickness | Length | Width |
| SE2119T-2-75 | 0.030 In. | 0.75 mm | 3.15 In. | 8 cm | 0.39 In. | 1 cm |
| SE2119T-2-10 | 0.039 In. | 1 mm | 3.15 In. | 8 cm | 0.39 In. | 1 cm |
| SE2119T-2-15 | 0.059 In. | 1.5 mm | 3.15 In. | 8 cm | 0.39 In. | 1 cm |
| SE2619T-2-75 | 0.03 In. | 0.75 mm | 4.13 In. | 10.5 cm | 0.39 In. | 1 cm |
| SE2619T-2-10 | 0.039 In. | 1 mm | 4.13 In. | 10.5 cm | 0.39 In. | 1 cm |
| SE2619T-2-15 | 0.059 In. | 1.5 mm | 4.13 In. | 10.5 cm | 0.39 In. | 1 cm |
Proudly made in the USA! Click here for more made in America products!
LabValues 2025 Promo!
For a limited time, enjoy special pricing on select Labnet Enduro™ Power Supplies!
(E0303, E0203)
Offer cannot be combined with other discounts or institutional pricing.
Offer not valid on previous purchases. Promo valid from 7/15/25 to 12/31/25 or while supplies last.
All terms and conditions apply.
ENDURO™ Power Supply
- Two models (300V and 250V) available
- For DNA, RNA, or protein electrophoresis, and blotting applications
- Constant voltage or constant current with automatic crossover
- 250 V model also offers a constant power operating mode
- Timed or continuous operation
- Short circuit and over current/ over voltage protection
- No load and load change detection system
- Programming includes option for automatic recovery after power failure
- 3 year warranty
The new Enduro™ Power Supplies meet a wide range of applications including DNA, RNA, and protein electrophoresis, blotting, and many others. Two models are available with voltage ranges to 300 V and current ranges to 3000 mA. Operating modes include constant voltage or constant current with automatic crossover. In addition, the 250V model offers a constant power operating mode.
All parameters, including voltage, current, power (250 V model only), and time are easily set using the membrane keypad and displayed digitally on the back lit LCD. Compact in design with a small footprint, the Enduro™ Power Supplies are also stackable to save space. For easy viewing and setting of parameters on the bench or on a shelf, the front of the power supply can be raised with the integral folding feet.
Specifications
| Model | 300V | 250V |
| Output Voltage Range/Increments | 2-300V/1V | 5-250V/1V |
| Output Current Range/Increments | 4-500mA/1mA | 10-3000mA/10mA |
| Output Power Range/Increments | 90 watts max/n.a. | 1-300W/1W |
| Operating Constant Modes | current or voltage | current, voltage, or power |
| Timer | 1 -99 min, or continuous | 1min. to 99h 59min or continuous |
| Programmable | no | Yes (20 program capacity) |
| Dimensions (W x D x H) | 19 x 25 x 8 cm | 19 x 25 x 8 cm |
| Weight | 2.6 lbs | 5.7 lbs |
| Input Voltage | 110-230 V | 110-230 V |
LabValues 2025 Promo!
For a limited time, enjoy UP TO 65% OFF select
Labnet Enduro™ GDS II Gel Documentation Systems!
(GDS2-1302, GDS2-1365, GDST2-1302)
Offer cannot be combined with other discounts or institutional pricing.
Offer not valid on previous purchases. Promo valid from 7/15/25 to 12/31/25 or while supplies last.
All terms and conditions apply.
ENDURO™ GDS II Gel Documentation System - GDS II & GDS Touch II
Product Features
- Region of interest (ROI) function allows optimal exposure in less than 30 seconds. No more multiple exposures to get good images!
- Transilluminator good for 30,000 hours so you won't need to buy replacement UV bulbs
- Save photo files as jpeg or 16bit Tiff files ideal for publication
- Made in U.S.A.
- Included fully-featured qualitative software ideal for creating publication and notebook-quality images
ENDURO™ GDS II Applications
- Visible protein stains like Coomassie blue or silver stain
- Designed for DNA
- Ethidium bromide
- Safe Dyes such as GelGreen® and SYBR™ Safe
ENDURO™ GDS II and GDS Touch II are the next-generation Gel Documentation Systems from Labnet International. These gel documentation systems are used for visualization of DNA and protein stained within a gel and provide photo documentation of these gels in a laboratory setting.
The GDS II comes in either a 302 nm or 365 nm version and runs on a Windows-based PC (not included).
The GDS Touch II comes in either a 302 nm or 365nm wavelength version with 470 nm epi-blue lights for use with Safe Dyes that eliminate the need for ethium bromide.
Both versions now come with a storage location on top to help maximize bench space and provide a place for accessories.
Specifications
| GDS II | GDST II | |
| Image Resolution | 3.2 MP | 3.2 MP |
| Field of View | 15 x 20 cm | 15 x 20 cm |
| Standard Illumination | UV (302 or 365nm), epi white | UV (302 or 365nm), epi-white, epi-blue |
| System Controls | Windows 10 PC or laptop (not included) | Windows 10 tablet (built-on) |
| USB 2.0 Ports | 2 | 2 |
| Dimensions | 12 x 15 inches (31 x 38 cm) | 12 x 15 inches (31 x 38 cm) |
| Certifications | cTUVus; CE | cTUVus; CE |
| Computer Specifications | PC or laptop* (not included) | Tablet included |
*PC or Laptop must meet the following minimum specifications
- Windows 10
- Intel® processor
- 1.4 GHz processor speed
- 2 GB RAM
- 16 GB free hard disk space
- 2 USB 2.0 or higher
Proudly made in the USA! Click here for more made in America products!
LabValues 2025 Promo!
For a limited time, enjoy special pricing on Labnet Enduro™ UV Transilluminators!
Offer cannot be combined with other discounts or institutional pricing.
Offer not valid on previous purchases. Promo valid from 7/15/25 to 12/31/25 or while supplies last.
All terms and conditions apply.
- Compact size with 21 x 26 cm viewing area
- Available in single or dual wavelength models
- Unique heavy duty hinge design can be held in place at any angle for gel cutting
- UV shield fully protects user from UV light
- Uniform UV Black Glass provides improved imaging contrast
ENDURO™ Semi Dry Blotter
- Western, Southern, and Northern Blots
- Rapid transfer times
- Uniform head dispersion
- Variable gel thickness
- Minimal buffer volume
The ENDURO™ Semi-Dry Blotter provides great flexibility in a lab since it can be used for all types of blotting: Western, Southern, and Northern. Blotting with the ENDURO™ Semi Dry Blotter typically can be done in 15 to 30 minutes making it a fast and easy way to do all your blotting applications. Set up procedures are easy and economical with little buffer needed. The screw down lid adjusts to varying gel thicknesses and sizes while the platinum coated electrodes provide uniform pressure ensuring even transfers. To provide your lab with total blotting solutions use with our ENDURO™ 250V, 3000mA high current power supply.
Specifications
|
Dimensions |
32.5
x 25 x 5.5 cm | 12.8 x 9.8 x 2.2 in |
|
Buffer Volume |
20 mL |
|
Sample Capacity |
4
Blots: 8 x 8.5 cm | 2 Blots: 16 x 8.5 cm | 1 Blot: 16 x 17.5 cm |
Semi-Dry Blotting Systems, 10cm x 10cm
Choose Galileo Insight™ semi-dry sytems for rapid and efficient molecular transfer.
Large Tank Blotter with two cassettes, 20 x 20cm
- Designed to optimally transfer very large and difficult proteins.
- Reproducible transfer results thanks to the plate electrodes made
- of platinum-plated titanium (anode) and stainless steel (cathode).
- Efficient cooling system: Water circulation system with alumina
- ceramic wall located at the chamber base for effective heat
- removal.
- Safety lid: asymmetrical configuration of electrical contacts
- prevents mismatching of electrodes.
Semi-Dry Blotting Systems, 20cm x 20cm
The larger format 2020 system is ideal for transfer of larger gels or simultaneous transfer of multiple smaller gels. System is supplied complete with power leads and a sample pack of our ultra-pure cotton fiber filter paper.
Electrophoresis System Bundle
Package Includes:
- Complete PR1MA™ myGel™ Mini system (E1101; includes gel box, power supply, and casting sets)
- SmartDoc™ 2.0 Gel Viewing and Smart Phone Imaging System (E5001-SDB)
- SmartGlow DNA Stain, 1.0 mL (BE4500-PS or BE4500-LD)
- Agarose LE, 100 grams
Uniform white light diffusion for viewing negative and film positives. X-ray film, autoradiographs, microtiter plates, and stained gels can be viewed on the white light transmitting glass surface. This surface, permanently double-safety sealed into the unit for durability, provides a scratch and chemical resistant work area which can be cleaned easily. Durable transilluminator housing is scratch resistant, epoxy powder paint finish for easy cleaning. 2 year warranty
| Model | Order No | Description | Filter Size | Dimensions |
| TW-26 | 95-0208-01 | White Light Transilluminator, 115V | 21 x 26cm | 9.5"D x 13.25"W x 4.25"H |
| TW-43 | 95-0214-01 | White Light Transilluminator, 115V | 36 x 43cm | 19.13"D x 16"W x 4.25"H |
Safety Certifications: ETL, ETL/c on all 115V models.
- Increased ultraviolet output and intensity
- No light flicker
- Wider intensity range with variable selection (select models)
- Fast lamp start up
- Universal power supply
- Reduced electrical consumption
- Longer tube life
- Lighter weight
- Improved gel visualization and gel documentation
- 2 year warranty
Visi-Blue Transilluminators are designed for use with GFP stains. As compared to UV, the blue light will transmit through almost any transparent (plastic, glass, etc.) laboratory equipment. This is essential when monitoring and detecting DNA migration and protein expression in real time.
- Two models are available with surface areas as follows: 21x26cm or 20x40cm
- Select from models with 8-watts or 25-watts
- Amber cover (included) blocks blue light transmission and allows visualization of media above 500nm