View:

Solid Door Built-In Vaccine Refrigerator


These premier built-in undercounter refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.
The ADA compliant, solid door refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, and probe access ports with included probes. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency.
 

REFRIGERATION SYSTEM


 COMPRESSOR HERMETIC, HIGH PERFORMANCE
 REFRIGERANT EPA SNAP COMPLIANT, R600A,   ISOBUTANE
 CONDENSER HYBRID FIN AND TUBE WITH LOW NOISE   FAN
 EVAPORATOR PLATE WALL
 DEFROST CYCLE OPTIMIZED, ZERO ENERGY
 
PERFORMANCE
 UNIFORMITY¹ (CABINET AIR) +/- 0.8°C
 STABILITY² (CABINET AIR) +/- 1.2°C
 MAXIMUM TEMPERATURE   VARIATION (CABINET AIR) +/- 1.4°C
 TEMPERATURE RISE AFTER AN   AFTER 8 SEC DOOR OPENINGS TEMPERATURE DID NOT EXCEED 6.4°C   AT ANY PROBE FOR ALL REQUIRED   NSF/ANSI 456 TESTING PROTOCOLS
 RECOVERY AFTER 3 MIN DOOR   OPENING ALL PROBES RECOVER TO UNDER 8°C   WITHIN 4.8 MIN.
 ENERGY CONSUMPTION 1.15 KWH/DAY
 AVERAGE HEAT REJECTION 1.57 KWH/DAY (224 BTU/H)
 NOISE PRESSURE LEVEL (DBA) 43 OR LESS INSTALLED
 PULL DOWN TIME TO NOMINAL   OPERATING TEMP 35 MIN



PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
  1. UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
  2. STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
  3. TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
  4. DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION.  HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION.  PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
 CONTROLLER TECHNOLOGY PARAMETRIC, MICROPROCESSOR, LED DISPLAY   WITH 0.1°C RESOLUTION
 TEMPERATURE SETPOINT RANGE 1°C TO 10°C (SETPOINT MUST REMAIN   UNALTERED FROM THE FACTORY SETTING TO   REMAIN COMPLIANT WITH NSF/ANSI   PERFORMANCE REQUIREMENTS)
 DISPLAY PROBE CALIBRATED, STAINLESS STEEL
 EXTERNAL ALARM CONNECTION STATE SWITCHING REMOTE ALARM CONTACTS
 ALARMS VISUAL AND AUDIBLE INDICATORS
 HIGH / LOW TEMPERATURE, COMPLIANT WITH   ALARM REQUIREMENTS DEFINED IN THE   NSF/ANSI STANDARD FOR VACCINE STORAGE
 SIMULATOR BALLAST 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA

Glass Door Freestanding Vaccine Refrigerator


These premier undercounter refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.

These glass door freestanding refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, LED interior lighting, and probe access ports with included probes. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency.
The acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C and 8°C) in the refrigerator and -58°F and 5°F (or -50°C and -15°C) in freezers.
*-one or more of these certifications may apply to this unit.

REFRIGERATION SYSTEM

 COMPRESSOR HERMETIC, HIGH PERFORMANCE
 REFRIGERANT EPA SNAP COMPLIANT, R600A,   ISOBUTANE
 CONDENSER TUBE AND GRID CONSTRUCTION,   FANLESS
 EVAPORATOR PLATE WALL
 DEFROST CYCLE OPTIMIZED, ZERO ENERGY
 
PERFORMANCE
 UNIFORMITY¹ (CABINET AIR) +/- 1.4°C
 STABILITY² (CABINET AIR) +/- 1.3°C
 MAXIMUM TEMPERATURE   VARIATION (CABINET AIR) +/- 1.7°C
 TEMPERATURE RISE AFTER AN   AFTER 8 SEC DOOR OPENINGS TEMPERATURE DID NOT EXCEED 6.4°C   AT ANY PROBE FOR ALL REQUIRED   NSF/ANSI 456 TESTING PROTOCOLS
 RECOVERY AFTER 3 MIN DOOR   OPENING ALL PROBES RECOVER TO UNDER 8°C   WITHIN 6 MIN.
 ENERGY CONSUMPTION 1.15 KWH/DAY
 AVERAGE HEAT REJECTION 1.67 KWH/DAY (224 BTU/H)
 NOISE PRESSURE LEVEL (DBA) 41 OR LESS INSTALLED
 PULL DOWN TIME TO NOMINAL   OPERATING TEMP 36 MIN


PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
  • UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
  • STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
  • TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
  • DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION.  HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION.  PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.

 CONTROLLER TECHNOLOGY PARAMETRIC, MICROPROCESSOR, LED DISPLAY   WITH 0.1°C RESOLUTION
 TEMPERATURE SETPOINT RANGE 1°C TO 10°C (SETPOINT MUST REMAIN   UNALTERED FROM THE FACTORY SETTING TO   REMAIN COMPLIANT WITH NSF/ANSI   PERFORMANCE REQUIREMENTS)
 DISPLAY PROBE CALIBRATED, STAINLESS STEEL
 EXTERNAL ALARM CONNECTION STATE SWITCHING REMOTE ALARM CONTACTS
 ALARMS VISUAL AND AUDIBLE INDICATORS
 HIGH / LOW TEMPERATURE, COMPLIANT WITH   ALARM REQUIREMENTS DEFINED IN THE   NSF/ANSI STANDARD FOR VACCINE STORAGE
 SIMULATOR BALLAST 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA

Solid Door Freestanding Vaccine Refrigerator Certified to NSF/ANSI 456


These premier undercounter refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.
These solid door freestanding refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, LED interior lighting, and probe access ports with included probes. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency.
\The acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C and 8°C) in the refrigerator and -58°F and 5°F (or -50°C and -15°C) in freezers.

REFRIGERATION SYSTEM

 COMPRESSOR HERMETIC, HIGH PERFORMANCE
 REFRIGERANT EPA SNAP COMPLIANT, R600A, PROPANE
 CONDENSER TUBE AND GRID CONSTRUCTION,   FANLESS
 EVAPORATOR PLATE WALL
 DEFROST CYCLE OPTIMIZED, ZERO ENERGY
 
PERFORMANCE
 UNIFORMITY¹ (CABINET AIR) +/- 1.4°C
 STABILITY² (CABINET AIR) +/- 1.3°C
 MAXIMUM TEMPERATURE   VARIATION (CABINET AIR) +/- 1.7°C
 TEMPERATURE RISE AFTER AN   AFTER 8 SEC DOOR OPENINGS TEMPERATURE DID NOT EXCEED 6.5°C   AT ANY PROBE FOR ALL REQUIRED   NSF/ANSI 456 TESTING PROTOCOLS
 RECOVERY AFTER 3 MIN DOOR   OPENING ALL PROBES RECOVER TO UNDER 8°C   WITHIN 6 MIN.
 ENERGY CONSUMPTION 1.15 KWH/DAY
 AVERAGE HEAT REJECTION 1.67 KWH/DAY (315 BTU/H)
 NOISE PRESSURE LEVEL (DBA) 41 OR LESS INSTALLED
 PULL DOWN TIME TO NOMINAL   OPERATING TEMP 42 MIN


PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
  • UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
  • STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
  • TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
  • DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION.  HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION.  PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.

 CONTROLLER TECHNOLOGY PARAMETRIC, MICROPROCESSOR, LED DISPLAY   WITH 0.1°C RESOLUTION
 TEMPERATURE SETPOINT RANGE 1°C TO 10°C (SETPOINT MUST REMAIN   UNALTERED FROM THE FACTORY SETTING TO   REMAIN COMPLIANT WITH NSF/ANSI   PERFORMANCE REQUIREMENTS)
 DISPLAY PROBE CALIBRATED, STAINLESS STEEL
 EXTERNAL ALARM CONNECTION STATE SWITCHING REMOTE ALARM CONTACTS
 ALARMS VISUAL AND AUDIBLE INDICATORS
 HIGH / LOW TEMPERATURE, COMPLIANT WITH   ALARM REQUIREMENTS DEFINED IN THE   NSF/ANSI STANDARD FOR VACCINE STORAGE
 SIMULATOR BALLAST 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA

Stainless Steel Built-In Vaccine Refrigerator


These premier built-in undercounter refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.
The stainless steel Refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, and probe access ports with included probes. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency.

REFRIGERATION SYSTEM

 COMPRESSOR HERMETIC, HIGH PERFORMANCE
 REFRIGERANT EPA SNAP COMPLIANT, R600A,   ISOBUTANE
 CONDENSER HYBRID FIN AND TUBE WITH LOW NOISE   FAN
 EVAPORATOR PLATE WALL
 DEFROST CYCLE OPTIMIZED, ZERO ENERGY
 
PERFORMANCE
 UNIFORMITY¹ (CABINET AIR) +/- 0.8°C
 STABILITY² (CABINET AIR) +/- 1.2°C
 MAXIMUM TEMPERATURE   VARIATION (CABINET AIR) +/- 1.4°C
 TEMPERATURE RISE AFTER AN   AFTER 8 SEC DOOR OPENINGS TEMPERATURE DID NOT EXCEED 6.4°C   AT ANY PROBE FOR ALL REQUIRED   NSF/ANSI 456 TESTING PROTOCOLS
 RECOVERY AFTER 3 MIN DOOR   OPENING ALL PROBES RECOVER TO UNDER 8°C   WITHIN 4.8 MIN.
 ENERGY CONSUMPTION 1.15 KWH/DAY
 AVERAGE HEAT REJECTION 1.57 KWH/DAY (224 BTU/H)
 NOISE PRESSURE LEVEL (DBA) 43 OR LESS INSTALLED
 PULL DOWN TIME TO NOMINAL   OPERATING TEMP 35 MIN


PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
  • UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
  • STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
  • TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
  • DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION.  HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION.  PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.

 CONTROLLER TECHNOLOGY PARAMETRIC, MICROPROCESSOR, LED DISPLAY   WITH 0.1°C RESOLUTION
 TEMPERATURE SETPOINT RANGE 1°C TO 10°C (SETPOINT MUST REMAIN   UNALTERED FROM THE FACTORY SETTING TO   REMAIN COMPLIANT WITH NSF/ANSI   PERFORMANCE REQUIREMENTS)
 DISPLAY PROBE CALIBRATED, STAINLESS STEEL
 EXTERNAL ALARM CONNECTION STATE SWITCHING REMOTE ALARM CONTACTS
 ALARMS VISUAL AND AUDIBLE INDICATORS
 HIGH / LOW TEMPERATURE, COMPLIANT WITH   ALARM REQUIREMENTS DEFINED IN THE   NSF/ANSI STANDARD FOR VACCINE STORAGE
 SIMULATOR BALLAST 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA

 

Glass Door Built-in Vaccine Refrigerator


These premier built-in undercounter refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.
The glass door refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, LED interior lighting, and probe access ports with included probes.

REFRIGERATION SYSTEM

 COMPRESSOR HERMETIC, HIGH PERFORMANCE
 REFRIGERANT EPA SNAP COMPLIANT, R600A,   ISOBUTANE
 CONDENSER HYBRID FIN AND TUBE WITH LOW NOISE   FAN
 EVAPORATOR PLATE WALL
 DEFROST CYCLE OPTIMIZED, ZERO ENERGY
 
PERFORMANCE
 UNIFORMITY¹ (CABINET AIR) +/- 0.8°C
 STABILITY² (CABINET AIR) +/- 1.2°C
 MAXIMUM TEMPERATURE   VARIATION (CABINET AIR) +/- 1.4°C
 TEMPERATURE RISE AFTER AN   AFTER 8 SEC DOOR OPENINGS TEMPERATURE DID NOT EXCEED 6.4°C   AT ANY PROBE FOR ALL REQUIRED   NSF/ANSI 456 TESTING PROTOCOLS
 RECOVERY AFTER 3 MIN DOOR   OPENING ALL PROBES RECOVER TO UNDER 8°C   WITHIN 4.8 MIN.
 ENERGY CONSUMPTION 1.15 KWH/DAY
 AVERAGE HEAT REJECTION 1.57 KWH/DAY (224 BTU/H)
 NOISE PRESSURE LEVEL (DBA) 43 OR LESS INSTALLED
 PULL DOWN TIME TO NOMINAL   OPERATING TEMP 35 MIN


PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
  • UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
  • STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
  • TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
  • DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION.  HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION.  PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.

 CONTROLLER TECHNOLOGY PARAMETRIC, MICROPROCESSOR, LED DISPLAY   WITH 0.1°C RESOLUTION
 TEMPERATURE SETPOINT RANGE 1°C TO 10°C (SETPOINT MUST REMAIN   UNALTERED FROM THE FACTORY SETTING TO   REMAIN COMPLIANT WITH NSF/ANSI   PERFORMANCE REQUIREMENTS)
 DISPLAY PROBE CALIBRATED, STAINLESS STEEL
 EXTERNAL ALARM CONNECTION STATE SWITCHING REMOTE ALARM CONTACTS
 ALARMS VISUAL AND AUDIBLE INDICATORS
 HIGH / LOW TEMPERATURE, COMPLIANT WITH   ALARM REQUIREMENTS DEFINED IN THE   NSF/ANSI STANDARD FOR VACCINE STORAGE
 SIMULATOR BALLAST 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA

Built-In Vaccine Refrigerator NSF/ANSI 456 Certified


These premier built-in undercounter refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.
The solid door refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, and probe access ports with included probes. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency.

REFRIGERATION SYSTEM

 COMPRESSOR HERMETIC, HIGH PERFORMANCE
 REFRIGERANT EPA SNAP COMPLIANT, R600A,   ISOBUTANE
 CONDENSER HYBRID FIN AND TUBE WITH LOW NOISE   FAN
 EVAPORATOR PLATE WALL
 DEFROST CYCLE OPTIMIZED, ZERO ENERGY
 
PERFORMANCE
 UNIFORMITY¹ (CABINET AIR) +/- 0.8°C
 STABILITY² (CABINET AIR) +/- 1.2°C
 MAXIMUM TEMPERATURE   VARIATION (CABINET AIR) +/- 1.4°C
 TEMPERATURE RISE AFTER AN   AFTER 8 SEC DOOR OPENINGS TEMPERATURE DID NOT EXCEED 6.4°C   AT ANY PROBE FOR ALL REQUIRED   NSF/ANSI 456 TESTING PROTOCOLS
 RECOVERY AFTER 3 MIN DOOR   OPENING ALL PROBES RECOVER TO UNDER 8°C   WITHIN 4.8 MIN.
 ENERGY CONSUMPTION 1.15 KWH/DAY
 AVERAGE HEAT REJECTION 1.57 KWH/DAY (224 BTU/H)
 NOISE PRESSURE LEVEL (DBA) 43 OR LESS INSTALLED
 PULL DOWN TIME TO NOMINAL   OPERATING TEMP 35 MIN


PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
  • UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
  • STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
  • TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
  • DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION.  HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION.  PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.

 CONTROLLER TECHNOLOGY PARAMETRIC, MICROPROCESSOR, LED DISPLAY   WITH 0.1°C RESOLUTION
 TEMPERATURE SETPOINT RANGE 1°C TO 10°C (SETPOINT MUST REMAIN   UNALTERED FROM THE FACTORY SETTING TO   REMAIN COMPLIANT WITH NSF/ANSI   PERFORMANCE REQUIREMENTS)
 DISPLAY PROBE CALIBRATED, STAINLESS STEEL
 EXTERNAL ALARM CONNECTION STATE SWITCHING REMOTE ALARM CONTACTS
 ALARMS VISUAL AND AUDIBLE INDICATORS
 HIGH / LOW TEMPERATURE, COMPLIANT WITH   ALARM REQUIREMENTS DEFINED IN THE   NSF/ANSI STANDARD FOR VACCINE STORAGE
 SIMULATOR BALLAST 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA

PERFORMANCE PHARMACY-VACCINE REFRIGERATORS

Designed and purpose-built for pharmacy, medication, and vaccination applications to support meeting CDC/VFC vaccine storage guidelines.

FEATURING:

  • Built-in readout for current and high/low temperature
  • Audible and visual high/low temperature alarms
  • Optimized efficient performance for stable temperature
  • Eco-friendly natural refrigerants for a greener footprint

 

ADVANCED TEMPERATURE CONTROL

  • Intelligent microprocessor digital temperature controller
  • Improved temperature accuracy with a buffered probe in glycol-filled bottle to simulate temperature of stored product
  • Additional sensor reads interior air temperature for superior temperature control
  • Adjustable operating control range from +2°C to +8°C (+35.6°F to +46.4°F)
  • Digital display of the min/max temperature (updated in 15 minute increments)
  • Temperature viewable in Celsius and Fahrenheit to the nearest tenth of a degree
  • Password protection of control parameters beyond setpoint
  • Optimized forced air cooling for excellent temperature stability and uniformity with rapid recovery after door openings and product loading

 

MULTIPLE ALARMS FOR SAFER MONITORING

  • Audible/visual alarms for high/low temperature excursions
  • Open door alarm sounds if the door is left ajar (default 4 minutes with selectable 1-99 minute range)
  • Audible power failure and sensor failure alarms
  • Mute function for alarms
  • Remote alarm contacts in rear of the unit

 

FULLY FEATURED INTERIOR FOR CONVENIENT STORAGE

  • Energy efficient LED lighting with internal on/off switch
  • Adjustable plastic-coated wire shelves for improved circulation
  • Multiple shelf positions spaced at ½ to allow flexible adjusting to support smaller items
  • Adjustable cycle defrost operation
  •  probe port included to accept user-provided monitoring equipment

 

QUALITY DESIGN FOR RELIABLE PERFORMANCE

  • Self-closing door offers added storage protection
  • User-reversible door swing (self-closing function compatible with RHD position only)
  • Environmentally-friendly natural hydrocarbon refrigerant for reduced global warming potential
  • Meets EPA and SNAP requirements
  • Convenient security with a top-mounted door lock (2 keys included)
  • Magnetic gaskets to ensure a positive seal
  • Pyxis®, Omnicell® and AcuDose RX® compatible

 

TECHNICAL SPECIFICIATIONS:

Model

Capacity

Height [in]

Width [in]

Depth [in]

Door

Cabinet

Shelves

Internal Fans

ARS1PV

1 Cu. Ft.

21.5

17.5

19.5

White

White

3

1

ARG1PV

1 Cu. Ft.

21.5

17.5

20

Glass

White

3

1

ARS3PV

3 Cu. Ft.

33.75

18.5

19

White

White

4

1

ARG3PV

3 Cu. Ft.

33.75

18.5

19.5

Glass

White

4

1

ARS6PV

6 Cu. Ft.

32.5

23.5

24.5

White

White

4

1

ARG6PV

6 Cu. Ft.

32.5

23.5

25

Glass

White

4

1

ARS8PV

8 Cu. Ft.

50

23.38

24.5

White

White

7

2

ARG8PV

8 Cu. Ft.

50

23.38

25

Glass

White

7

2

ARS12PV

12 Cu. Ft.

61.75

23.38

24.5

White

White

7

2

ARG12PV

12 Cu. Ft.

61.75

23.38

25

Glass

White

7

2

ARS15PV

15 Cu. Ft.

72

23.5

24.5

White

White

7

2

ARG15PV

15 Cu. Ft.

72

23.5

25

Glass

White

7

2

 

TECHNICAL SPECIFICATIONS (ALL UNITS):

  • Defrost: Cycle
  • Thermostat: Intelligent microprocessor digital
  • Temperature Sensors: 2 (air probe and buffered probe)
  • Adjustable Operating Control Range: 2°C to +8°C (+35.6°F to +46.4°F)
  • Preset: 5ºC/41ºF
  • Temperature Variation: +/-1°C
  • Shelving: White plastic coated wire
  • Voltage: 115V/60Hz
  • Cord: NEMA 5-15P
  • Lock: Factory-installed key lock
  • Refrigerant: Eco-friendly R600a
  • Light: LED
  • Access Port: 
  • Door: Reversible
  • Fan: Internal
  • Certifications: ETL, ETL-C
  • Parts & Labor Warranty: 2 years
  • Compressor Warranty: 5 years

 

INCLUDED

  • DO NOT UNPLUG warning sticker
  • DO NOT ADJUST TEMPERATURE warning sticker
  • DO NOT STORE PERSONAL ITEMS warning sticker

 

OPTIONS

  • NIST calibrated temperature readout with 2-year certificate of conformity
  • Digital data logger (DDL) installed or as kit with 2-year certificate of conformity
Item#:
ASPHARVACREF1

PERFORMANCE PHARMACY-VACCINE REFRIGERATORS

Designed and purpose-built for pharmacy, medication, and vaccination applications to support meeting CDC/VFC vaccine storage guidelines.

FEATURING:

  • Built-in readout for current and high/low temperature
  • Audible and visual high/low temperature alarms
  • Optimized efficient performance for stable temperature
  • Eco-friendly natural refrigerants for a greener footprint

 

ADVANCED TEMPERATURE CONTROL

  • Intelligent microprocessor digital temperature controller
  • Improved temperature accuracy with a buffered probe in glycol-filled bottle to simulate temperature of stored product
  • Additional sensor reads interior air temperature for superior temperature control
  • Adjustable operating control range from +2°C to +8°C (+35.6°F to +46.4°F)
  • Digital display of the min/max temperature (updated in 15 minute increments)
  • Temperature viewable in Celsius and Fahrenheit to the nearest tenth of a degree
  • Password protection of control parameters beyond setpoint
  • Optimized forced air cooling for excellent temperature stability and uniformity with rapid recovery after door openings and product loading

 

MULTIPLE ALARMS FOR SAFER MONITORING

  • Audible/visual alarms for high/low temperature excursions
  • Open door alarm sounds if the door is left ajar (default 4 minutes with selectable 1-99 minute range)
  • Audible power failure and sensor failure alarms
  • Mute function for alarms
  • Remote alarm contacts in rear of the unit

 

FULLY FEATURED INTERIOR FOR CONVENIENT STORAGE

  • Energy efficient LED lighting with internal on/off switch
  • Adjustable plastic-coated wire shelves for improved circulation
  • Multiple shelf positions spaced at ½ to allow flexible adjusting to support smaller items
  • Adjustable cycle defrost operation
  •  probe port included to accept user-provided monitoring equipment

 

QUALITY DESIGN FOR RELIABLE PERFORMANCE

  • Self-closing door offers added storage protection
  • User-reversible door swing (self-closing function compatible with RHD position only)
  • Environmentally-friendly natural hydrocarbon refrigerant for reduced global warming potential
  • Meets EPA and SNAP requirements
  • Convenient security with a top-mounted door lock (2 keys included)
  • Magnetic gaskets to ensure a positive seal
  • Pyxis®, Omnicell® and AcuDose RX® compatible

 

TECHNICAL SPECIFICIATIONS:

Model

Capacity

Height [in]

Width [in]

Depth [in]

Door

Cabinet

Shelves

Internal Fans

ARS1PV

1 Cu. Ft.

21.5

17.5

19.5

White

White

3

1

ARG1PV

1 Cu. Ft.

21.5

17.5

20

Glass

White

3

1

ARS3PV

3 Cu. Ft.

33.75

18.5

19

White

White

4

1

ARG3PV

3 Cu. Ft.

33.75

18.5

19.5

Glass

White

4

1

ARS6PV

6 Cu. Ft.

32.5

23.5

24.5

White

White

4

1

ARG6PV

6 Cu. Ft.

32.5

23.5

25

Glass

White

4

1

ARS8PV

8 Cu. Ft.

50

23.38

24.5

White

White

7

2

ARG8PV

8 Cu. Ft.

50

23.38

25

Glass

White

7

2

ARS12PV

12 Cu. Ft.

61.75

23.38

24.5

White

White

7

2

ARG12PV

12 Cu. Ft.

61.75

23.38

25

Glass

White

7

2

ARS15PV

15 Cu. Ft.

72

23.5

24.5

White

White

7

2

ARG15PV

15 Cu. Ft.

72

23.5

25

Glass

White

7

2

 

TECHNICAL SPECIFICATIONS (ALL UNITS):

  • Defrost: Cycle
  • Thermostat: Intelligent microprocessor digital
  • Temperature Sensors: 2 (air probe and buffered probe)
  • Adjustable Operating Control Range: 2°C to +8°C (+35.6°F to +46.4°F)
  • Preset: 5ºC/41ºF
  • Temperature Variation: +/-1°C
  • Shelving: White plastic coated wire
  • Voltage: 115V/60Hz
  • Cord: NEMA 5-15P
  • Lock: Factory-installed key lock
  • Refrigerant: Eco-friendly R600a
  • Light: LED
  • Access Port: 
  • Door: Reversible
  • Fan: Internal
  • Certifications: ETL, ETL-C
  • Parts & Labor Warranty: 2 years
  • Compressor Warranty: 5 years

 

INCLUDED

  • DO NOT UNPLUG warning sticker
  • DO NOT ADJUST TEMPERATURE warning sticker
  • DO NOT STORE PERSONAL ITEMS warning sticker

 

OPTIONS

  • NIST calibrated temperature readout with 2-year certificate of conformity
  • Digital data logger (DDL) installed or as kit with 2-year certificate of conformity
Item#:
ASPHARVACREF

Premier Refrigerator With Built-In Pharmacy/Vaccine Undercounter


The Premier Laboratory Refrigerators feature a microprocessor temperature controller and display, allowing for precise temperature control, verification and recovery versus mechanical style thermostats. An interior fan driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings.  Critical samples and supplies are security backed with an extensive package of audible and visual alarms.  A variety of door types and sizes are available  ranging from 10 to 72 cubic feet.

The temperature display and alarm module offers an array of robust security features with a monitoring and alarm system that is 100% independent of a microprocessor temperature controller.
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines

  • Cycle Defrost
  • 115v, 60 Hz, 5.4 Amps, 1/3 Hp, Btu/hr 4932
  • Ul/c-ul Listed
  • Energy Star Certified
  • Shipping Weight: 295 Lbs.
  • Microprocessor Temperature Controller
  • Adjustable Operating Temperature Range: 1°c to 10°c
  • Standard Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
  • Sample Simulated Digital Temperature Display; .1° Resolution
  • Adjustable Temperature Display in Celsius or Fahrenheit
  • Audible and Visual High/low Temperature Alarms
  • Sensor Error Alarm
  • Power Failure Alarm
  • Resettable 1-point Min/max History
  • Remote Alarm Contacts
  • Alarm Validation (Audible, Visual, and Remote Alarm)
  • Alarm Mute With Ring Back
View: