|◀ 13 - 24 of 40 ▶|
View:

IBI RT-PCR Certified and Nuclease-Free Water is ideal for all applications in a molecular biology lab including PCR, RT-PCR, restriction enzyme
assays, modifying enzyme assays, transfection, cloning, transformation, and all general molecular biology lab procedures.


IBI PCR Grade water is manufactured under stringent conditions. The purification process includes continuous deionization, reverse osmosis,
UV-treatment, 0.2µm filtration, followed by steam sterilization in an autoclave.

IB42300

PCR Grade Water,nuclease free,1.8 mL vial

IB42301

PCR Grade Water,nuclease free,(20)x 1.8 mL vial

IB42302

PCR Grade Water,nuclease free,(50) x 1.8 mL vial

IB42303

PCR Grade Water,nuclease free,(100) x 1.8 mL vial

Item#:
ASPCRWATER2


Vion Ultrapure ASTM Type I Water

 

Our ultrapure, ASTM Type I, water meets the strictest standards defined by the American Society for Testing and Materials (ASTM). It is ideal for a wide range of ultra-sensitive laboratory uses include gas chromatography, HPLC, mass spectrometry, atomic absorption spectroscopy, and trace analysis.

 

Specifications
 
Resistivity≥ 18 MΩ
Conductivity≤ 0.056 uS / cm
Total Organic Carbon (TOC)≤ 50 ppb
Silicate (as SiO2)≤ 3 ppb
Chloride (Cl)≤ 1 ppb
Sodium (Na)≤ 1 ppb
Endotoxin≤ 0.03 EU / mL
Heterotrophic BacteriaCount (HBC)≤ 10 CFU / L
 

Proudly made in the USA! Click here for more made in America products!
 

Item#:
ASASTMWATER


Vion ACS Reagent Grade Water

 

Vion ACS Reagent grade water is guaranteed to meet the purity standards set by the American Chemical Society (ACS). It is a high-quality, highly purified water with minimal contaminants, and is ideal for use in laboratory settings for sensitive chemical analyses, like liquid chromatography and UV-Visible spectrophotometry, and reactions where extreme purity is required.

 

Specifications
 
Conductivity≤ 2.0 uS / cm
Silicate (as SiO2)≤ 0.01 ppm
Heavy Metals (as Pb)≤ 0.01 ppm
Substances Reducing PermanganatePasses Test
Chloride (Cl)≤ 0.4 ppm
Nitrate (NO3)≤ 0.4 ppm
Phosphate (PO4) ≤ 1 ppm
Sulfate (SO4)≤ 1 ppm
UV A300 nm≤ 0.005
UV A254 nm≤ 0.005
UV A210 nm≤ 0.010
UV A200 nm≤ 0.010
LC AbsorbancePasses Test
LC Gradient ElutionPasses Test
 

Proudly made in the USA! Click here for more made in America products!
 

Item#:
ASACSWATER


Sodium Bicarbonate

  • Appearance: White Crystalline Powder
  • Purity: 99.0 - 100.5%
  • pH (5% Aqueous): 7.9 - 8.4
  • Water: ≤ 0.25%
  • Lead: ≤ 5 ppm
  • Arsenic: ≤ 2 ppm
  • Chloride: ≤ 150 ppm
  • Sulfate: ≤ 150 ppm
  • RNase: None Detected
  • DNase: None Detected

*Custom sizes available upon request.

 

DOT Information: Non-regulated.   
 

Item#:
ASBICARBSODIUM

IBI Cell Culture Grade, Pyrogen/Endotoxin Free Water is prepared for nuclear transfer, transfection, transformation, cell and tissue culture,
LAL testing, and all other aqueous solution preparations that require stringent quality control.


IBI Cell Culture Grade Water is tested for use in critical assays and applications. The water is endotoxin-free (to the maximum detection
limit of <0.005EU/ml by turbidimetric assay). The purification process of our Cell Culture Grade Water includes distillation, continuous
deionization, reverse osmosis, 0.1µm filtration, followed by steam sterilization in an autoclave.


IB42010

Cell Culture Grade Water, Pyrogen and Endotoxin Free, 1L

IB42011

Cell Culture Grade Water, Pyrogen and Endotoxin Free, 6 x 1L

IB42012

Cell Culture Grade Water, Pyrogen and Endotoxin Free, 12 x 1L

IB42020

Cell Culture Grade Water, Pyrogen and Endotoxin Free, 2L

IB42021

Cell Culture Grade Water, Pyrogen and Endotoxin Free, 6 x 2L

IB42030

Cell Culture Grade Water, Pyrogen and Endotoxin Free, 10L

Item#:
ASMOLWATER
  • RNase & DNase Free Water A new process of purifying large quantity of DNase and RNase free water enables us to offer Molecular Grade Water at a price that any laboratory can afford. 

  • No toxic agents such as DEPC are used in making the Molecular Grade Water; therefore, there is no chance of DEPC interfering with enzymatic reactions. 

  • The Molecular Grade Water is suitable for use in molecular biology applications which demand a high quality of water and assurance that the water is free from DNase and RNase contamination. 

  • Molecular Grade Water can be used for making reagents and rinsing glass/plastic wares for DNA and RNA research. 

  • Each lot is quality tested for the absence of RNase and DNase contamination. Test reports are attached with each container as an added assurance.
Item#:
ASMOLWATER2


Sucrose

  • Appearance (Color): White
  • Appearance (Form): Crystalline Powder
  • Purity: ≥ 99.0%
  • Identity (FTIR): Conforms to Structure
  • Solubility (1M Aqueous): Clear and Colorless
  • pH (1M Aqueous): 5.5 - 7.5
  • Conductivity (1M Aqueous): ≤ 35 uS / cm
  • Specific Rotation: 65.5° to 67.5°
  • Water: ≤ 0.2%
  • A260 (1M Aqueous): ≤ 0.09
  • A280 (1M Aqueous): ≤ 0.07
  • RNase: None Detected
  • DNase: None Detected

*Custom sizes available upon request.

 

DOT Information: Non-regulated.

 

Item#:
ASUSROSE1


Sodium Sulfate

  • Appearance: White Crystalline Powder
  • Purity: ≥ 99.0%
  • pH (5% Aqueous): 5.2 - 9.2
  • Identification (FTIR): Conforms to Structure
  • Water: ≤ 0.5%
  • Insoluble Matter: ≤ 0.01%
  • Loss on Ignition: ≤ 0.05%
  • Chloride: ≤ 10 ppm
  • Nitrogen: ≤ 5 ppm
  • Phosphate: ≤ 10 ppm
  • Lead: ≤ 5 ppm
  • Iron: ≤ 10 ppm
  • DNase: None Detected
  • RNase: None Detected

*Custom sizes available upon request.

 

DOT Information: Non-regulated.   
 

Item#:
ASODIUMSULF
Discontinued, Contact us for more options!

IBI DEPC-Treated, Nuclease-Free Water is ideally suited for all applications in molecular biology lab including PCR, RT-PCR, restriction enzyme
assays, modifying enzyme assays, transfection, cloning, transformation, and specifically for all RNA assays.


IBI DEPC-Treated Water is manufactured under stringent conditions. The purification process for this product includes continuous
deionization, reverse osmosis, UV-treatment, 0.1µm filtration, followed by steam sterilization in an autoclave. The product is re-autoclaved
to ensure the breakdown of DEPC and release of carbon dioxide that may cause the pH to shift.


IB42200

DEPC Treated Water, nuclease free, 125mL

IB42201

DEPC Treated Water, nuclease free, 24 x 125mL

IB42202

DEPC Treated Water, nuclease free, 48 x 125 mL

IB42210

DEPC Treated Water, nuclease free, 500 mL

IB42211

DEPC Treated Water, nuclease free, 10 x 500 mL

IB42212

DEPC Treated Water, nuclease free, 20 x 500 mL

IB42220

DEPC Treated Water, nuclease free, 1L

IB42221

DEPC Treated Water, nuclease free, 6 x 1L

IB42222

DEPC Treated Water, nuclease free, 12 x 1L

IB42230

DEPC Treated Water, nuclease free, 2L

IB42231

DEPC Treated Water, nuclease free, 6 x 2L

IB42240

DEPC Treated Water, nuclease free, 10L

Item#:
ASPCRWATER1


Dextrose (D-Glucose)

  • Appearance (Color): White to Off-White
  • Appearance (Form): Crystalline Powder
  • Purity: ≥ 99.5%
  • Solubility (2 g / 15 mL): Clear and Colorless
  • Identity (FTIR): Conforms to Structure
  • Conductivity: ≤ 20 uS / cm
  • Specific Rotation: 52.6° to 53.2°
  • Water: ≤ 1.0%
  • Lead: ≤ 0.5 ppm
  • Sulfates: ≤ 200 ppm
  • Chloride: ≤ 125 ppm
  • Sulfated Ash: ≤ 0.1%
  • Calcium: ≤ 200 ppm
  • Endotoxins: ≤ 1.25 EU/g
  • RNase: None Detected
  • DNase: None Detected

*Custom sizes available upon request.

 

DOT Information: Non-regulated.   
 

Item#:
ASDEXANHY


PR1MA bis-Acrylamide, 2% Solution

CAS Number: 110-26-9
Storage Temp: 2-8°C

A 2% (w/v) bis-Acrylamide solution.

Research or further manufacturing use only, not for food or drug use.

  • Appearance: Clear, colorless liquid
  • Conductivity of Solution: Report µmhos
  • Electrophoresis: Pass Test
  • pH: Report

Proudly made in the USA! Click here for more made in America products!
 
 


PR1MA Acrylamide/bis-Acrylamide, Premixed Powder 29:1 Ratio

Storage Temp: Room Temperature

Pre-measured powder blend of acrylamide and bis-acrylamide for simple stock solution preparation.

WARNING!
This product can expose you to Acrylamide, a chemical which is known to the State of California to cause cancer, developmental and reproductive harm. For more information go to www.P65Warnings.ca.gov.

Research or further manufacturing use only, not for food or drug use.

  • Appearance: White Powder
  • Conductivity of Solution: ≤ 10.0 µmhos
  • Electrophoresis: Pass Test
  • Solubility: Pass Test

Proudly made in the USA! Click here for more made in America products!
 
 

|◀ 13 - 24 of 40 ▶|
View: