| Item | Â | Â |
| MH-10 | Nose Restraint Slide for MH-100 | Fits 1" inner diameter mouse tube. |
| MH-12 | Nose Restraint Slide for MH-125 | Fits 1.25" inner diameter Mouse tube |
| MH-20 | Nose Restraint Slide for MH-200 | Replacement nose restraint and thumb screw for MH-200 |
| MH-30 | Nose Restraint Tube | Replacement nose restraint with thumb screw for MH-300 Large Rat holder |
Mouse restraints from IBI offer the researcher a new, humane method for restraining laboratory mice to administer injections and obtain needed samples. The mouse restrains are available in two sizes.
MH-100Â - The 1" diameter solid acrylic tubular mouse holder features 4 access ports and a full length vertical slot for easy access to specimen. The adjust slide/stop ensures the mouse will not move during experiment.
MH-125Â - The 1.25" diameter solid acrylic tubular mouse holder features 8 access ports and full length vertical slot for easy access to samples. The adjust slide/stop ensures the mouse will not move during experiment.
Rat restraints from IBI offer the researcher a new, humane method for restraining laboratory mice to administer injections and obtain needed samples. The rat restrains are available in three sizes.
MH-200 - The 2" diameter solid acrylic tubular mouse holder features 4 access ports and a full length vertical slot for easy access to specimen. The adjust slide/stop ensures the rat will not move during experiment.
MH-250 - The 2.5" diameter solid acrylic tubular mouse holder features 5 access ports and full length vertical slot for easy access to samples. The adjust slide/stop ensures the rat will not move during experiment.
MH-300 - The 3" diameter solid acrylic tubular mouse holder features 6 access ports and full length vertical slot for easy access to samples. The adjust slide/stop ensures the rat will not move during experiment.
- Holds mouse restraint at 45 degree angle
- Allows for easy access to tail for bleeds
- Holds restraint securely
The MH-550 is designed to hold the MH-100 and MH-125 at a 45 degree angle to allow for easy access to the mouse tail for bleeds or other procedures.
The stand is constructed of cast acrylic for years of reliable service.
Made in the USA
Dynalon's Dura-Cross tank is ideal for breeding of Zebrafish. Manufactured from transparent and autoclavable food grade polycarbonate, it is fully impact resistant and will not chip or break. The tank consists of a tapered tank body, a slotted insert, and lid, and it is stackable to save space.
Dura-Cross easily and effectively optimizes the breeding of zebra fish and is available as single pieces or in cases of 25.
Features include:
- Manufactured from food grade polycarbonate, making it virtually indestructible and with glass-like clarity for maximum viewing of fish and eggs
- Unique slotted insert ensures eggs are separate from adults, maximizing yield; insert can be removed to allow adult fish to be quickly and safely returned to main habitat tank
- Molded lid keeps tank and fish environment clean and is designed for easy stacking; has two ¼" holes for air tubing
- Optional Dividers available in diagonal or straight formats to keep males and females separate as required
- Optional Carrying Tray allows for safe transport of tanks and holds 5 tanks in a single layer or 10 tanks stacked
- Tanks and accessories are dishwasher safe and autoclavable
- Tank dimensions: 8" X 4" X 3"
Notice for U.S. Customers – RWD Consumables
Due to changes in U.S.–China tariffs, we will pause sales of these items after Tuesday, April 22, until further notice.
This is in anticipation of the expected De Minimis rule change on May 2.
For more information or alternative product recommendations, please contact us.
RWD Osmotic Pumps
Â
With competitive prices, RWD miniature infusion pumps are designed for precise and continuous long-term dosing in mice and rats, durations for up to 6 weeks, which relieves researchers who are burdened by multiple injections.
Â
Osmotic Pumps can be implanted subcutaneously or intraperitoneally for systemic administration or connected to a catheter to provide targeted delivery for blood vessels, brain, spinal cord, lung, liver, or other specific areas of infusion.
Â
The Osmotic Pump consists of a robust semi-permeable membrane that allows animals’ fluids to pass through. Built-in high-pressure salt interlayer absorbs animal fluids, causing them to expand and squeeze the drug storage capsule. The liquid stored in the capsule can be delivered to specific tissue areas continuously and accurately at a constant rate.Â
Â
The pump can be implanted directly into the peritoneal cavity or the back of the neck to deliver the drug. The pump rate is stable through in-vivo testing.
Â
*Made of biocompatible material to avoid immune rejection after implantation in rats and mice. Each pump is also sterilized by irradiation to ensure no inflammatory reaction in mice and rats.
Â
Applications include cardiovascular disease model, addiction research, emotion-based research, medication research for diabetes and other metabolic diseases, pain, injury, and other therapeutic drug infusions, and cancer drug screening.
- Predictable dosing minimizes experimental variables to ensure reproducible and consistent results.
- Reduces the stress response by continuous administration without frequent animal handling. Ensures experimental results and animal welfare is guaranteed.
- Wide application, easy to operate. Reduces the need for regular injections at night and on weekends.
Specifications
| Capsule | Item # | 1003D | 1001W | 1002W | 1004W | 1006W | 2003D | 2001W | 2002W | 2004W | 2ML1W | 2ML2W | 2ML4W |
| Capacity | 100 uL | 200 uL | 2 mL | ||||||||||
| Duration | 3 D | 1 W | 2 W | 4 W | 6 W | 3 D | 1 W | 2 W | 4 W | 1 W | 2 W | 4 W | |
| Pump Rt. (uL / hr) | 1 | 0.5 | 0.25 | 0.125 | 0.083 | 2 | 1 | 0.5 | 0.25 | 10 | 5 | 2.5 | |
| Flow Regulator | Cap | Without | PE material | ||||||||||
| Tube | 304 stainless steel material | ||||||||||||
| Infusion | Syringe | Flat head for the injection of liquid | |||||||||||