S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Pall® AcroPrep™ Advance 96-well Filter Plates for Ultrafiltration
- Provides rapid, efficient separation of biomolecules
- Omega™ membrane provides high recovery and typically results in > 90% recovery of target biomolecules
- New well design results in faster, more uniform filtration rates across the plate with reduced hold-up volume for maximum sample recovery
- Intrinsic plate and membrane properties prevent target molecules from binding to the plate
|
Item |
Description |
|
8033 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Ultrafiltration - 350 µL, Omega
3K MWCO (10/pkg) |
|
8034 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Ultrafiltration - 350 µL, Omega
10K MWCO (10/pkg) |
|
8035 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Ultrafiltration - 350 µL, Omega
30K MWCO (10/pkg) |
|
8036 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Ultrafiltration - 350 µL, Omega
100K MWCO (10/pkg) |
|
8163 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Ultrafiltration - 1 mL, Omega 3K
MWCO (5/pkg) |
|
8164 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Ultrafiltration - 1 mL, Omega 10K
MWCO (5/pkg) |
|
8165 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Ultrafiltration - 1 mL, Omega 30K
MWCO (5/pkg) |
|
8166 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Ultrafiltration - 1 mL, Omega
100K MWCO (5/pkg) |
Pall® AcroPrep™ Advance 96-well Filter Plates for Lysate Clearance
- Prefilter Provides Efficient Clarification Highly Particulated Samples
- Integrated pre filter yields consistent filtration of samples with high levels of gross particulate
- New well geometry results in faster, more uniform filtration rates across the plate with reduced hold-up volume
- Innovative outlet tip geometry provides direct flow of samples into receiver plate without concerns of cross-contamination
- Manufactured with biologically inert materials that allow clarification of most types of lysates without loss of target molecules
|
Item |
Description |
|
5231 |
Pall®
AcroPrep™ Multi-well plate lids (10/pkg) |
|
8040 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Lysate Clearance - 350 µL, 3.0 µm
Glass Fiber/1.2 µm Supor membrane (10/pkg) |
|
8075 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Lysate Clearance - 350 µL, 3.0 µm
Glass Fiber/0.2 Supor membrane (10/pkg) |
|
8175 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Lysate Clearance - 1 mL, 3.0 µm
Glass Fiber/0.2 µm Supor membrane (5/pkg) |
|
8275 |
Pall®
AcroPrep™ Advance 96-well Filter Plates for Lysate Clearance - 2 mL, 3.0 µm
Glass Fiber/0.2 µm Supor membrane (5/pkg) |
Pall® MicroFunnel™
ST Filter Funnels
- Convenient and Economical Choice for Sterility Testing Within Isolators
- MicroFunnel ST filter funnels offer an alternative to costly closed-system sterility testing when using an isolator or containment suite
- 0.45 μm GN-6 Metricel® membrane or low binding Supor® membrane provides a choice for sterility testing applications in the pharmaceutical industry
- Supor membrane is ideal for testing antibiotic solutions
- Double bagged packaging ensures easy transfer through airlock
- Simple squeeze separation design makes membrane retrieval easy
- Meets requirements of U.S., Japan, and European Pharmacopeias for sterility testing
Pall® Microsep® Advance Centrifugal Devices
- Precise, Quick Recovery of Microliter Volumes
- Rapidly concentrates 0.5-5 mL sample volumes to 65–100 μL.
- Achieve 50X concentration and > 90% recovery in just minutes
- Deadstop feature prevents samples from spinning to dryness
- Versatile Omega™ membrane is available in a variety of MWCOs
- Color-coded and laser etched for easy identification
Pall® 47
mm, In-line Filter Holders
The 47 mm filter holders are designed for in-line liquid or gas filtration. They open and close easily without disturbing the filter disc.
- Designed for in-line liquid or gas filtration
- Easy open and close
- Available in a variety of materials
They are available in polycarbonate and aluminum.
For venting and air monitoring applications, the sturdy plastic construction of the lightweight polycarbonate 47 mm in-line filter holder is ideal.
For stack sampling applications, the 47 mm in-line filter holder in anodized aluminum is a durable and cost-effective choice.
For excellent chemical resistance and continuous processing
of fluids at high pressure, the 47 mm in-line filter holder in stainless steel
is recommended.
Pall® Laboratory Manifold
A unique microbiology manifold that allows you to optimize testing without sacrificing cleanliness. With interchangeable components and coupling devices, the manifold takes direction from you.
- No more “dirty” manifolds: Microbial cross contamination of your sample is a thing of the past. The manifold is designed to fit most laboratory autoclaves by separating into manageable components.
- Double testing capacity: A larger manifold is at your reach with just a coupler. Modular design allows two manifolds to combine yielding a standard 6-place manifold which can be easily separated for disinfection and/or sterilization.
- Manifolds that adapt to you: Whether you are right or left-handed, setting up your test workflow is second nature. The components interchangeable and designed with a simple slip fit to the manifold.
Applications
Bioburden testing of filterable products is performed to determine the number of viable and reproducible microorganisms. By recovering organisms on and in a membrane filter, processing efficiency and the microbial quality of a sample can be evaluated to assure that the product is not harmful to the intended recipient.
Detecting spoilage microorganisms are critical for foods and beverages as they may be responsible for the deterioration of sensory qualities (visual, texture, and taste) and may potentially render the product harmful for consumption. Using membrane filtration, detection of these spoilage microorganisms keep contaminated items from reaching the market.
Monitoring for compliance to drinking water standards using Membrane Filtration Technique, determines if there are levels of pathogenic microorganisms in treated water or wastewater. These microorganisms include coliforms such as Escherichia coli (E. coli) and Legionella which are both classified as pathogens.Pall® Acro®
50 Vent Devices
- 50 mm Filters with Superior Performance for Demanding Applications
- Reusable and autoclavable
- PTFE membrane and polypropylene housing have broad chemical resistance
- Large surface area provides greater throughput and high air flow rate
- Available with a variety of inlet and outlet connectors