S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
ActionsLab Refrigerators
Our wide range of lab refrigeration equipment is guaranteed to meet your laboratory research, testing, and storage needs thanks to an extensive selection of possible features, such as:
-
Low-E double-pane thermal glass for superior temperature stability.
-
Attention-grabbing alarms and digital displays that mitigate perilous temperature variations.
-
Non-peel/non-chip vinyl exteriors, heavy-duty PVC coated wire shelves, or NSF-approved white aluminum interiors with 300 series stainless steel flooring for augmented durability.
-
Cycle defrost that keeps regular maintenance to a minimum and frees up your time.
-
Energy Star technology that minimizes your power consumption expenses.
-
CFC-free 134A refrigerant for enhanced environmental friendliness
Standard Glass Door Chromatography Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Microprocessor Temperature Controller
- Digital Temperature Display
- Audible and Visual High and Low Temperature Alarms
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Remote Alarm Contacts
- Adjustable Operating Temperature: 1°c to 10°c
Templog Premier Glass Door Chromatography Refrigerator
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°c - 10°c
- Touch Screen Digital Temperature Display and Alarm Module
- Password-protected Control Panel
- Sample Simulated Digital Temperature Display; .1° Resolution, Adjustable Temperature Display in Celsius or Fahrenheit
- Active Temperature Scale Bar Display
- Resettable 1-point Min/max History and Digital 24-hour Temperature Chart Temperature Data Logging
- Usb Port for Data Transfer and Software Updates
- Real-time Operational Display Clock
- 4-20ma Output
- Electronic Troubleshooting Guide
- Electronic Qr Code to Access Owner’s Manual & Technical Support Contact Info Adjustable Alarm Volume
- Audible and Visual High/low Temperature Alarms
Premier Glass Door Chromatography Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Shipping Weight: 283 Lbs. Note: This Unit Requires Two (2) Outlets
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°-10°c
- Digital Temperature Display and Alarm Module
- Sample Simulated Digital Temperature Display; .1° Resolution
- Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- Sensor Error Alarm
- Power Failure Alarm
- Resettable 1-point Min/max History
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Alarm Validation (Audible, Visual, and Remote Alarm)
- Alarm Mute With Ring Back
Solid Door Built-In Vaccine Refrigerator
REFRIGERATION SYSTEM
COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
EVAPORATOR | PLATE WALL |
DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
STABILITY² (CABINET AIR) | +/- 1.2°C |
MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
ENERGY CONSUMPTION | 1.15 KWH/DAY |
AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
ALARMS | VISUAL AND AUDIBLE INDICATORS |
HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Pharmacy Solid Door Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
- Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
- Standard Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
- Sample Simulated Digital Temperature Display; .1° Resolution
- Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- 2 Probes; 1 in Air and 1 in Sample Bottle
Pharmacy Stainless Steel Laboratory Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 6 Amps, 3/8 Hp
- Etl Listed
- Shipping Weight: 295 Lbs.
- Microprocessor Temperature Controller
- Digital Temperature Display With Battery Back-up to Support Temperature Monitoring and Alarms
- Audible and Visual High and Low Temperature Alarms
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
NEW! Haier solid-door pharmacy refrigerators!
Pre-order now to ensure you get yours.
New models (HYC-85FD, HYC-461FD, HYC-1031FD) will be in stock and available starting November 2024.
Haier Pharmacy Refrigerators
Used for storage of medicines, vaccines, reagents, biological products and other items that require a temperature between 2-8°C. Used in hospitals, pharmacies, pharmaceutical factories, clinics and laboratories etc.
- Energy Efficient: Each unit uses eco-friendly refrigerants: R290 (HYC-1031GD) and R600a (HYC-461GD) and offers low power consumption relative to performance
- Temperature Uniformity: Extends the shelf life of stored items and eliminates inconsistent results
- Insulation: Features polyurethane insulation
- Alarm Functions: Comes with multiple alarm functions, including audible/visual alerts for monitoring, and some include remote alarm contacts
- Cooling System: Uses hermetically sealed compressors and forced-air circulation for efficient cooling. Includes auto defrost
- Security: All models have security features, including a unique-key lock for safe storage
- Accessibility: Adjustable wire shelves are standard across all models to improve circulation and flexible storage
- Display and Controls: Integrated digital control panels with microprocessors are used in all models, allowing for precise temperature control and easy monitoring
- Low Noise Operation: All models are designed for quiet operation (35 – 43 dB(A))
Glass Door Freestanding Vaccine Refrigerator
COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
CONDENSER | TUBE AND GRID CONSTRUCTION, FANLESS |
EVAPORATOR | PLATE WALL |
DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
UNIFORMITY¹ (CABINET AIR) | +/- 1.4°C |
STABILITY² (CABINET AIR) | +/- 1.3°C |
MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.7°C |
TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6 MIN. |
ENERGY CONSUMPTION | 1.15 KWH/DAY |
AVERAGE HEAT REJECTION | 1.67 KWH/DAY (224 BTU/H) |
NOISE PRESSURE LEVEL (DBA) | 41 OR LESS INSTALLED |
PULL DOWN TIME TO NOMINAL OPERATING TEMP | 36 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
ALARMS | VISUAL AND AUDIBLE INDICATORS |
HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Built-In Pharmacy Stainless Steel Undercounter Refrigerator
- Width: 23 ¾"
- Depth: 24 ½”
- Height: 33 3/8"
- Cycle Defrost
- 115v, 60 Hz, 1/8 Hp, 1.74 Amps
- Ul/c-ul Listed
- Energy Star Certified
- Shipping Weight: 137lbs.
- Microprocessor Temperature Controller
- Digital Temperature Display
- Audible and Visual High and Low Temperature Alarms
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
- Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
Glass Door Stainless Steel Pharmacy Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Microprocessor Temperature Controller
- Digital Temperature Display With Battery Back-up to Support Temperature Monitoring and Alarms
- Audible and Visual High and Low Temperature Alarms
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Adjustable Operating Temperature Range: 36°f to 46°f
Solid Door Freestanding Vaccine Refrigerator Certified to NSF/ANSI 456
COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
REFRIGERANT | EPA SNAP COMPLIANT, R600A, PROPANE |
CONDENSER | TUBE AND GRID CONSTRUCTION, FANLESS |
EVAPORATOR | PLATE WALL |
DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
UNIFORMITY¹ (CABINET AIR) | +/- 1.4°C |
STABILITY² (CABINET AIR) | +/- 1.3°C |
MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.7°C |
TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.5°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6 MIN. |
ENERGY CONSUMPTION | 1.15 KWH/DAY |
AVERAGE HEAT REJECTION | 1.67 KWH/DAY (315 BTU/H) |
NOISE PRESSURE LEVEL (DBA) | 41 OR LESS INSTALLED |
PULL DOWN TIME TO NOMINAL OPERATING TEMP | 42 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
ALARMS | VISUAL AND AUDIBLE INDICATORS |
HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Standard Pharmacy Glass Door Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Microprocessor Temperature Controller
- Digital Temperature Display
- Audible and Visual High and Low Temperature Alarms
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
- Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm