S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
ActionsSureAir™ PCR Workstation
SureAir™ PCR Workstation
The SureAir is designed to keep your workspace clean easy-to-use, and organized. An included germicidal UVC light eliminates any stray DNA that may contaminate samples, and is programmed to automatically shut off after 15 minutes. To protect users, the UVC light is only operational when the
Specifications
UV Light: | 8W UVC |
UV Auto-Shutoff Timer: | 15 minutes |
Materials: | UV-Resistant Polycarbonate |
Outer Dimensions (W x D xH): | 21.7x15.7x23.3in. |
Inner Dimensions (WxDxH): | 197x154×15.7in. |
Hand Access Dimensions (W xH): | 197×6.3 in. |
Filter: | 0.3 um 99.97% HEPA |
Air Velocity: | 0.2 m/s |
Electrical: | 115V or 230V. 50/60 Hz |
Power Consumption: | TOW |
Weight: | 44 lbs |
Warranty: | 2 years |
Mystaire® PCR Prep Stations
They are compact laminar flow enclosures that reduce the risk of sample contamination while performing polymerase chain reaction experiments.
Airborne contaminants are prevented from entering into the work zone through constant positive pressure HEPA filtered air. Each PCR prep station is equipped with a built-in 254 nanometer shortwave lamp to effectively decontaminate the work area between amplifications. Safety interlocks are included on all PCR prep stations to prevent operator exposure to potentially harmful UV radiation.
MY-PCR prep stations are bench-top personal clean zones allowing the operator to amplify RNA and DNA while minimizing the potential for background from airborne contaminants.
Note: MY-PCR and FE-PCR are not biological safety cabinets. They are designed to provide process protection only from potential airborne contaminants found in the laboratory space.
MY-PCR WORKSTATIONS FEATURES
- Class 100 vertical laminar flow air
- 15-Minute UV light timer
- Clear polycarbonate construction with chemically impervious polypropylene work surface
- UV shelf with integrated pipette holder
- Electrical cord pass-through port
Sash position switch and overlap to prevent UV light exposure
Specs |
MY-PCR24 |
MY-PCR32 |
MY-PCR48 |
Width |
24" |
32" |
48" |
Depth |
24" |
||
Height |
30" |
||
Noise Level |
<45 DBA |
<49 DBA |
<56 DBA |
Voltage |
110 V or 220 V |
||
Power |
200 Watts |
400 Watts |
|
UV Light |
15 W/254 mm |
15 W/254 mm (2) |
|
Blower |
Sparkless Brushless |
||
UV Light Timer |
0-15 min. |
||
Safety Interlock |
Yes |
||
Air Velocity |
60 LFM |
HEPA Filters, Pre-Filters, UV bulbs, additional ports and shelves also available.
Mystaire® CleanPrep™ dead air boxes are circulation-free enclosures that establish an ideal work area to protect against contamination in sensitive PCR amplification reactions. CleanPrep™ workstations are constructed from thermally-fused polypropylene that offers exceptional chemical resistance, does not adsorb moisture and can be easily cleaned and decontaminated between amplifications using a variety of disinfectant solutions.Seamless polypropylene design for easy decontamination between amplifications.
FEATURES:
- Clear polycarbonate access with overlap and safety position switch
- UV shelf with integrated pipette holder - accommodates four pipettors
- High intensity fluorescent lamps and shortwave UV light
- Available in 36 and 48 inch widths with nominal 24 inch depth
- Circulation-free enclosure for PCR applications
Technical Specifications |
|||||
Specifications |
MY-DB24 |
MY-DB36 |
MY-DB48 |
||
Physical Dimensions (W x H x D inches) |
|||||
Outside Dimensions |
24 x 30 x 24 |
36 x 30 x 24 |
48 x 30 x 24 |
||
Inside Dimensions (usable work area) |
23 x 20 x 23 |
35 x 20 x 23 |
47 x 20 x 23 |
||
Weight |
45 lb. |
60 lb. |
80 lb. |
||
Airflow Characteristics |
|||||
Low Airflow Alarm |
N/A |
N/A |
N/A |
||
Volume of Filtered Air |
N/A |
N/A |
N/A |
||
Linear Face Velocity, Sash Closed |
N/A |
N/A |
N/A |
||
Linear Face Velocity |
N/A |
N/A |
N/A |
||
Electrical |
|||||
Voltage |
110 V or 220 V |
110 V or 220 V |
110 V or 220 V |
||
Current |
1.4 A/0.7 A |
1.4 A/0.7 A |
2.8 A/1.4 A |
||
Power Consumption |
115 W |
115 W |
115 W |
||
Operation |
|||||
Speed Selection |
N/A |
N/A |
N/A |
||
Construction |
|||||
Chamber |
Structural Polypropylene |
Structural Polypropylene |
Structural Polypropylene |
||
Front Panel |
Polycarbonate |
Polycarbonate |
Polycarbonate |
||
Prefilter (On top housing) |
|||||
Type (particulate) |
N/A |
N/A |
N/A |
||
Weight |
N/A |
N/A |
N/A |
||
Dimensions |
N/A |
N/A |
N/A |
||
Requirements |
N/A |
N/A |
N/A |
||
Filter |
|||||
Type (Provides HEPA Clean Work Area) |
N/A |
N/A |
N/A |
||
Weight |
N/A |
N/A |
N/A |
||
Dimensions |
N/A |
N/A |
N/A |
||
Requirements |
N/A |
N/A |
N/A |
||
HEPA Filters, Pre-Filters, UV bulbs, additional ports and shelves also available.
- The CleanSpot is designed to fulfill a very important laboratory need...control of PCR contamination.
- Just 25 - 30 minutes of UV irradiation in the CleanSpot can prevent unwanted PCR contamination.
- The combination of a special light reflector and two powerful overhead UV bulbs generate Pyrimidine Dimers (T,C) and other photo defects in contaminating target sequences, thus eliminating falsely primed products that result in countless lost time and expense.
- The CleanSpot is designed to prevent unwanted contaminant DNA in amplification mixtures, thereby saving many lost hours and expensive samples.
- The UV resistant acrylic enclosure provides a contained, dead air space in which to set up your reactions and permits safe 254nm UV irradiation of solutions and supplies. This powerful UV wavelength renders DNA contaminants biologically inactive in 30 minutes or less.
- The thick front panel is an effective beta irradiation shield as well as acting as a breath guard. An overhead fluorescent light illuminates the work area.
- Dimensions: 18"L x 24"W x 28"H
- 1 year warranty
Eye and face protection are essential for anyone working with ultraviolet light sources. UV radiation can cause delayed reactions of sunburn to unprotected eyes and skin. Choose from three styles of comfortable eye/face protection: spectacles, goggles, or faceshield. Spectacles are made of impact resistant polycarbonate. The top and side shield design provide full UV protection for the eyes. Goggles are constructed of specially-formulated plastic giving optimum viewing contrast and lessened eye fatigue. The lightweight design and flexible rubber trim of the goggles fit comfortably on the face, even over prescription glasses. Air vents are located on each side of the goggles to allow air flow while blocking UV. The faceshield covers the face and neck area.
Eyewear complies with ANSI-Z87.1 specifications for safety eyewear and NIOSH Document HSM-83-1109. Criteria for a Recommended Standard - Occupational Exposure to Ultraviolet Radiation.
Eye and face protection are essential for anyone working with ultraviolet light sources. UV radiation can cause delayed reactions of sunburn to unprotected eyes and skin. Choose from three styles of comfortable eye/face protection: spectacles, goggles, or faceshield. Spectacles are made of impact resistant polycarbonate. The top and side shield design provide full UV protection for the eyes. Goggles are constructed of specially-formulated plastic giving optimum viewing contrast and lessened eye fatigue. The lightweight design and flexible rubber trim of the goggles fit comfortably on the face, even over prescription glasses. Air vents are located on each side of the goggles to allow air flow while blocking UV. The faceshield covers the face and neck area.
Eyewear complies with ANSI-Z87.1 specifications for safety eyewear and NIOSH Document HSM-83-1109. Criteria for a Recommended Standard - Occupational Exposure to Ultraviolet Radiation.
Eye and face protection are essential for anyone working with ultraviolet light sources. UV radiation can cause delayed reactions of sunburn to unprotected eyes and skin. Choose from three styles of comfortable eye/face protection: spectacles, goggles, or faceshield. Spectacles are made of impact resistant polycarbonate. The top and side shield design provide full UV protection for the eyes. Goggles are constructed of specially-formulated plastic giving optimum viewing contrast and lessened eye fatigue. The lightweight design and flexible rubber trim of the goggles fit comfortably on the face, even over prescription glasses. Air vents are located on each side of the goggles to allow air flow while blocking UV. The faceshield covers the face and neck area.
Eyewear complies with ANSI-Z87.1 specifications for safety eyewear and NIOSH Document HSM-83-1109. Criteria for a Recommended Standard - Occupational Exposure to Ultraviolet Radiation.