View:


Disposable Cuvettes and Caps

 

MTC Bio's disposable cuvettes are compatible with most popular spectrophotometers. Manufactured from high-quality, optically clear polystyrene. They are intended for determinations in the 340 to 800 nm (visible) wavelength range. Available in 3 sizes: 1.5 mL micro, 2.5 mL semi-micro, and 4.5 mL macro. All sizes are 12.5 mm square and 45 mm height and are compatible with various spectrophotometer models, including Carolina®, Spectronic®200, Spectronic®20 and 20D, Spectronic®Educator, Genesys, and Accuris SmartDrop.

Caps are available and can be ordered separately.

  • Fits most spectrophotometers and photometers
  • Polystyrene for use in visible range (340-800 nm)
  • Dust-proof, non-scratch protective packaging
  • Absorption reproductivity error of ≤1%

Specifications 
 
Path Length0.39 In. | 10 mm
Dimensions (D x W x H)0.49 x 0.49 x 1.77 In. | 12.5 x 12.5 x 45 mm
Wavelength Range340 to 800nm (Visible)
MaterialPolystyrene
Temp Range4°C to 70°C
AbsorptionLess than + / - 1%
 

Item#:
ASMTCDISPOCUV

VIS and UV-VIS Cuvettes

Polystyrene (VIS) and Methacrylate (UV-VIS) Cuvettes. Optically superior designs specifically for fluorimetry make this an excellent choice for nephelometry and spectrophotometry. A negligible variation in absorbance between the 4 optical sides allows readings from any side. The polystyrene cuvettes are accurate in the 340 to 750 nm visible spectral range. The methacrylate cuvettes are accurate throughout the 285 to 750 nm UV-VIS spectral range. Standard 1 cm light path.

Item#:
ASBASELCT2

Disposable VIS and UV-VIS cuvettes 

Cuvettes, UV-VIS Range Semi-Micro, 1.5 mL (Item 302225-0002)

Injection molded from a superior grade of methacrylate designed for accuracy throughout the VIS-UV spectral range from 300 nm to 750 nm. Excellent optical qualities throughout the spectral range make these cuvettes perfect for scanning small volumes, enzyme rate reactions, and standard curve determinations. Windows: 5 x 23 mm.

Cuvettes, Visible Range Semi-Micro, 1.5 mL (Item 302205-0002)

These exceptionally fine-quality polystyrene cuvettes are designed for assays throughout the 340 nm to 750 nm visible spectral range. A standard 1 cm light path and recessed windows provide maximum light transmission. Scale down your assay volumes to save on costly reagents using these specially designed cuvettes that have a minimum filling volume of 1.2 mL. Windows: 5 x 23 mm.

Cuvettes, Visible Range Macro, 4.5 mL (Item 302195-0002)

Designed for assays throughout the 340 nm to 750 nm visible spectral range. These specially designed cuvettes handle up to 4.5 mL total volume with a minimum filling volume of 2.5 mL and a maximum of 4.5 mL. Molded arrow indicates the direction of transmission for optimal signal and reproducibility. Windows: 10 x 35 mm   
 

Item#:
ASBASELCT1
for the Implen OD600


DiluCell™ Disposable Cuvettes

 

DiluCell provides automatic dilution of higher concentrated samples for standard 1 cm cuvette-compatible spectrophotometers. DiluCell 10 allows automatic 1/10 dilutions. Combined with small sample volume requirements and bubble-free filling, the DiluCell allows for convenient spectrophotometric analysis from 340 – 1100 nm.

 

Previously it was necessary to use standard cuvettes with a volume of at least 1 ml and additionally to dilute the sample manually. DiluCell from Implen allows for lower sample volume requirements and provides automatic virtual sample dilution. Due to the unique design of DiluCell cuvettes, the light-path is reduced from the standard 10 mm to 1.0 mm (DC 10). According to the Lambert Beer Law, this shortened pathlength results in an automatic sample dilution by factor 10 (DC 10). Automatic dilution with DiluCell saves time and excludes dilution errors and cross contaminations.  
 

Item#:
ASSPECTORP2


Electroporation Cuvette

 

These cuvettes are compatible with most electroporation systems. The cap has been designed to improve aseptic handling techniques, while the lip and positive seal reduce potential aerosol and contamination issues. Available in 1 mm, 2 mm, and 4 mm gap sizes with individual color caps. Every cuvette is guaranteed sterile, packed using gamma irradiation, and has a simple tear wrapper for easy access when you need it. All 1 mm and 2 mm cuvettes have a tapered V bottom so that reduced sample volumes can be used while aiding sample pick up and minimizing dead volumes.

 

The Cell Projects range of HiMaX Electroporation cuvettes is designed to maximize molecular electroporation and electrofusion efficiencies for Bacteria, Yeast, Insects, Plants, and mammals. Each batch of cuvettes must undergo rigorous testing at several stages during the manufacturing process for engineering tolerances, biocompatibility, and sterility before being Quality tested for optimal and reproducible impedance measurements.

 

All batches are checked to optimize bio- and Transfection compatibility. Stringent use of high-quality polycarbonate and chemicals ensures consistent, uniform pulse generation and improved gene transfer.

 

The molding process ensures extremely high tolerances so that the electrodes have a consistent gap and parallel configuration. The electrodes are also cleaned chemically and physically to fully optimize the cuvette for high transformation efficiencies.
 

Item#:
ASSPECTORP

Visable and UV Cuvettes

  • Visible Range Cuvettes
  • Designed for high reproducibility
  • Disposable
  • Include optical windows for optimum transmittance
  • Variations within range of 1% absorption
Item#:
ASVIANDUVCUV

Semi-Micro Cuvette 1.5 mL

Cuvette, four clear sided, macro, PS or UV-transparent, assorted by one cavity number, minimum filling volume 2,5 ml.

Suitable for fluorescence spectroscopy. The UV-transparent cuvette can be used from a wavelength of 230 nm and shows no autofluorescence. Specially designed for photometric determination of proteins, ssDNA, RNA and oligonucleotides in the UV range.

Usable starting from 220 nm. Ideally suited for measurement at 260 nm, 280 nm and in the visible range.
  • Standard 10 mm light path
  • Sample volumes as small as 70 μL are sufficient
  • Two center heights available
  • Fits most photometers without adapter
  • Clear, clean optical path
  • Manufactured under controlled room conditions and packaged fully automatically, without human contact
  • Packed grouped by mold cavity number to ensure lowest variation of extinction coefficient
  • The UV-transparent cuvettes replace sensitive and expensive glass or quartz cuvettes in many areas
Item#:
ASSEMIMICUV1