S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
ActionsMicroplate Readers and Microplate Washer
MIDSCI carries a line of low cost microplate readers and microplate washers that don’t sacrifice quality, performance, nor reliability.
Are you looking for a microplate reader and washer? You’ve come to the right place. We carry microplate readers and microplate washers that are right for you.
If you need a compact and economical microplate reader that works with your computer without a hitch, then the Chromate microplate reader is a good choice.
Yet if you want some convenient artificial intelligence on your side, then take a look at the Accuris microplate reader instead. It has an intuitive screen and provides measurement data, interpretations, and calculated analyses on the screen after a reading.
Of course if it’s a microplate washer you’re looking for, then the Stat Fax 2600 is superb. Other than the expected features for a microplate washer (and more), it’s also convenient to use and extra quiet!
This is just the tip of the iceberg. We’ve got a lot more to offer.
SmartReader™ 96 Microplate Absorbance Reader
- Intuitive, 7-inch color touchscreen control panel
- Filter-based system with wavelength range from 340 to 750 nm
- Operates as a stand-alone system, with USB flash drive for data transfer
- Absorbance range: 0.0 to 4.0000 Abs
- 8-channel vertical optical path, with zero dispersion
- Integrated, multi-speed plate shaker
- MR9600-T features temperature-controlled plate incubation
The Accuris™ SmartReader™ 96 MR9600 and MR9600-T are welcome additions to any lab that is routinely measuring concentration or absorbance in 96 well plates. The 7-inch touchscreen, intuitive software and graphical interface make these instruments easy to use as a standalone reader (a separate computer and additional software are not required).
The SmartReader™ 96 comes complete with 4 popular filters: 405, 450, 492, 630 nm, and twenty-six additional filters are available separately to cover a full range from 340 to 750 nm. The integrated filter wheel allows up to 8 filters to be loaded at once, and filters can be selected during programming
Use the touchscreen or connect a mouse for programming and operation. The menu interface allows the user to choose the wavelength filter, set shaking parameters, enter details of the plate layout, and choose the details for the reading protocol and data calculations.
Model MR9600-T offers precise temperature control for incubation of plates during processing. Temperature can be maintained at 5°C above ambient to 50°C.
Up to two filters can be used for 2 measurements of the sample plate, for calculated comparisons. Kinetic calculations can be performed by setting multiple readings.
The SmartReader™ 96 is a convenient stand-alone reader, all software and the programing system is incorporated into the electronics. However, a convenient USB port on the side allows quick and easy saving of data files to a USB drive, and the universal .csv files can then be shared or transferred to a computer for storage or further processing. A data port can be used for connecting a computer or basic printer.
The plate layout interface allows for quick and intuitive setup of a plate's well contents. The display shows a graphical representation of the 96-well plate, and the user can label each well as required for: "known standard", "unknown sample", "blank well", "QC control well", "negative control", "positive control", or "empty". The interface allows highlighting and labeling multiple wells to save time.
Measurement data is available immediately on the screen after reading, as well as interpretations, calculated analysis, and curve fittings.
Click here to Watch Specs Video!
Specifications
Precision | CV |
Test Speed | <6 sec. for 96 well plate |
Incubator (MR9600-T) | Temp control from ambient +5°C to 50°C |
Shaking | 3 modes: slow (3.5Hz), medium (4.7Hz), fast (7.0Hz) |
User Interface | Integrated software, touch screen control |
Storage | 200 programs, 100,000 test records |
Ports | USB ports for PC, printer, mouse and flash drive |
Dimensions | 29.5 x 44.0 x 22.5 cm 11.6 x 17 x 8.75 inches |
Weight | 10 kg |
SmartWasher™ 96 Microplate Washer
- Precision Control of Aspiration Needle Position
- Accurate to 0.1 mm
- Minimal residual liquid
- Auto rinse function eliminates cross contamination
- Up to 100 wash protocols can be customized and stored
- Liquid level sensors in wash and waste bottles
- Wash protocols can be transferred via flash drive
The SmartWasher™ 96 provides flexibility by accepting full plates, partial plates, and strips with U, V, C, or flat bottoms. Multiple aspiration point settings allow for minimal residual liquid in the wells after aspiration. All parameters, including dispense volume, suction time, soak and shake cycles, and shaking speed are easily programmed using the large 4.3" LCD display and keypad. Up to 100 wash protocols can be stored on board the SmartWasher™ 96 and recalled when needed or transferred between machines with a flash drive.
The washer comes with 2 wash bottles, 1 rinse bottle and a waste bottle. All have sensors that alert the user when the solutions are low, or in the case of the waste bottle, when it needs to be emptied. An auto-rinse function primes the dispensing tube and wash heads to prevent cross contamination and clogs.
8- and 12-channel wash heads are available separately to accommodate plates in either orientation. A transparent, acrylic shield surrounds the wash area, allowing for visualization of the plate. Should a spill or leak occur, the beveled spill well ensures that the liquid is extracted immediately to avoid cross-contamination.
The SmartWasher™ 96 is the perfect partner for the SmartReader™ 96 Microplate Absorbance Reader as well as other popular readers.
Specifications
Wash Heads | 1 x 8 or 1 x 12 |
Plate Types | Flat, U, V, or C bottom |
Washing Volume | 50-2000 μL, in 50 μL increments |
Dispensing Accuracy | ≤2% @ 300 μL |
Dispensing Precision | CV ≤1.5% @ 300 μL |
Aspiration Modes | Single, two, and three points |
Residual Liquid | ≤1 μL |
Soaking & Shaking Time | 1 second to 99 minutes |
Shaking Speed | Slow, medium, fast |
Bottle Capacity | 4 x 2.5 L, 2 wash, 1 rinse, 1 waste |
Data Connection | USB for flash drive |
Dimensions (W x D x H) | 13.6 x 18.11 x 7.87 In. | 345.44 x 460 x 199.90 mm |
Weight | 12 kg. | 26.4 lbs. |
Electrical | 110-240 VAC, 50 / 60 Hz |
- Compact and economical
- Reads absorbances of 96-wells in under 10 seconds
- Streamlined design to fit any lab bench
- Ready to "plug and play" with your PC
MIDSCI introduces Chromate, a compact 8-channel microplate reader. Its streamlined design with minimal footprint offers superb optics to fit any sized lab bench. Chromate and your PC team up to provide rapid reading and full access to high level software, reporting, curve fitting, and data storage to meet the requirements of modern laboratories. Instrument and software come ready to "plug and play" with your PC.
Photometric: |
|
Linear Measurement Range: |
-0.20 to 4.0 absorbance units (A) |
Photometric Accuracy: |
±1% |
Stability: |
Drift of no more than 0.005A in 8 hours |
Light Source: |
Remote halogen lamp source with lamp saver feature |
Wavelengths: |
Standard: 405, 450, 492, and 630nm |
Filter options from 405nm to 700nm |
|
Filter Type: |
IAD hardcoat interference, 10nm half bandpass |
Vessel: |
Standard 96-well microtiter plates, or strip trays |
Electronic: |
|
Power Requirements: |
115V or 230V, 50-60Hz (auto-sensing) |
PC Connection |
USB port |
Speed |
Reads absorbances of 96 wells in about 8 seconds |
Software: |
|
Calculation Modes: |
Single-point calibration, point-to-point curve fit, polynomial regression, linear and sigmoidal regression (log & linear), cutoff absorbance, multipoint % absorbance |
Additional Features: |
User-programmable open system, selectable plate formatting, alphanumeric test naming, automatic interpretation options, duplicate well options, curve plotting and editing, flags and error messages |
Dimensions: |
7.25 x 7.25 x 16.5 inches |
Weight: | 10 lbs. |
Warranty |
1 year |
This unit can be customized with upgraded filters or more filters. Please contact your Lab Consultant or our Tech Department at 800-227-9997 for more information. The item # would be 4300-CUSTOM and is not available to order on-line. Prices may vary. Lead time is 4-6 weeks on the Custom orders.
Chromate Microplate Reader
- Compact and economical
- Reads absorbances of 96-wells in under 10 seconds
- Streamlined design to fit any lab bench
- Ready to "plug and play" with your PC
Specifications:
Photometric: | |
Linear Measurement Range: | -0.20 to 4.0 absorbance units (A) |
Photometric Accuracy: | ±1% |
Stability: | Drift of no more than 0.005A in 8 hours |
Light Source: | Remote halogen lamp source with lamp saver feature |
Wavelengths: | Standard: 405, 450, 492, and 630nm |
Filter options from 405nm to 700nm | |
Filter Type: | IAD hardcoat interference, 10nm half bandpass |
Vessel: | Standard 96-well microtiter plates, or strip trays |
Electronic: | |
Power Requirements: | 115V or 230V, 50-60Hz (auto-sensing) |
PC Connection | USB port |
Speed | Reads absorbances of 96 wells in about 8 seconds |
Software: | |
Calculation Modes: | Single-point calibration, point-to-point curve fit, polynomial regression, linear and sigmoidal regression (log & linear), cutoff absorbance, multipoint % absorbance |
Additional Features: | User-programmable open system, selectable plate formatting, alphanumeric test naming, automatic interpretation options, duplicate well options, curve plotting and editing, flags and error messages |
Dimensions: | 7.25 x 7.25 x 16.5 inches |
Weight: | 10 lbs. |
Warranty | 1 year |
We are no longer distributing Cerillo Stratus Plate Readers.
For more information or to explore alternative options, please contact us or visit here.
Available units while supplies last.
Cerillo Stratus Plate Readers
A plate reader designed by anaerobic researchers, for anaerobic researchers.
The Stratus plate reader is small enough to fit in the palm of your hand and allows for measurement collection in small spaces, on shared or modular benchtops, and even in restrictive environments, like anaerobic or microaerophilic chambers. Its uniquely simple, standalone interface and on-board data storage allow it to be placed anywhere, with or without a computer.
- Withstands heating, shaking, and anaerobic conditions
- Small footprint allows for use (and storage) in the smallest of spaces
- Can be used with or without a computer
- Affordable!
The Stratus plate reader has new and improved capabilities to optimize
flexibility for sample data collection in multiple standard plate formats
to serve the wide-ranging needs of scientific researchers.
- Continuous real-time measurements of optical density
- Available in Standard 600 nm or customized wavelength
- Standard 6-, 12-, 24-, and 96-well plates
- Small footprint and stackable
- No moving parts; minimal maintenance
- Functional in a broad range of environments
- User-friendly software
Applications Include
- Bacterial Growth/Density
- Protein Quantification
- Enzyme-linked Immunosorbent Assay
- Reporter Gene Assays
- Cell Proliferation
- Cytotoxicity/Apoptosis
Plate Reader Product Description:
The Stratus plate reader is small enough to fit in the palm of your hand
and allows for measurement collection in small spaces, on shared or modular
benchtops, and even in restrictive environments, like anaerobic or
microaerophilic chambers and incubators.
Its uniquely simple, standalone interface and on-board data storage allow
it to be placed anywhere, with or without a computer.
Overall, the Stratus exploits the best of modern technology to reduce labor
and allow you to spend your efforts where they matter most. Cerillo has
been uncompromising in the Stratus's design and performance; all that's
left is for you to try it yourself.
Wavelength |
600nm
(Note: Customized wavelengths available)
|
Dimensions |
Width: 14.4 cm (5.7 in.) Depth: 13.0 cm (5.1 in.) Height: 6.8 cm (2.7 in.)
|
Weight |
580 g (20.5 oz.) |
Ambient Atmospheric Tolerance |
Temperature: 0° to 50°C (32° to 122°F) Humidity: 0 to 99% O2 concentration: Any CO2 concentration: Any
|
Sterilization Techniques |
Chemical surface treatment
(recommended)
EtO Gas Sterlization
|
Plate Formats |
96 -well, 24-well, 12-well, 6-well, |
Temporal Resolution |
Up to 30 plate reads per hour (user-defined)
|
OD Resolution |
±0.005 at OD600 |
Data Storage |
microSD-compatible memory slot, |
Power Supply |
5V, 500 mA USB Supply |
Adapter
The Cerillo Stratus adapter is precision-manufactured out of a high-quality, durable material designed to stand up to rigorous use in the lab. It allows a Stratus be secured to a universal shaker plate via screws, and also features high-friction silicone strips and powerful neodymium magnets. The adapter features a plate-size extrusion allowing it to fit securely to small shakers designed for a microplate.
Adapter Product Description
The adapter is designed for use with orbital shakers, microplate shakers, and shaking incubators. Unique attachment method allows for either magnetic attachment, screw attachment, or via silicone rubber footing on rubber mats. The adapter is reusable.
Additional Adapter Information
- Material: Thermoset Epoxy Resin
- Screws: #10-24 × 5/8 inch (15.875 mm) flat Philips head for aluminum, captive mounting screws
- Ratings up to 500 RPM in beta test cases.
- Item Weight: 125 g (4.5 oz)
SmartReader™ MultiMode Plate Reader
- Intuitive, 10-inch color touch screen
- Stand-alone system with optional PC software (FDA CFR Part 11)
- Monochromator-based system for UV through visible absorbance
- Filter module system for fluorescence assays
- Advanced PMT detector for luminescence assays
- Optional automatic injection modules for flash luminescence
- ELISA Assays
- Colorimetrics Assays (Bradford, Lowry, etc.)
- Enzyme Kinetics
- Spectral Scanning
- DNA & RNA Analysis
- …and more
STAT FAX 4200 Microplate Reader
The Stat Fax 4200 Microplate Reader is a compact, microprocessor-controlled, multi-purpose
photometer system designed to read and calculate the results of assays, which are read in 96
well microtiter plates or strip trays. The microplate reader may be used for in-vitro diagnostics. It is a user-programmable open system with selectable plate formatting, alphanumeric test naming, automatic interpretation options, duplicate well options, curve plotting and editing, flags and error messages from which the user can create a menu of pre-programmed assays for instant recall. This instrument is intended to be used as a stand-alone instrument without a PC but it has a connection in the event a user wishes to download results.
Stat Fax 4200 reads monochromatically (optional) or bichromatically (optional) and has two
models:
- Four-filter model (405, 450, 492, and 630 nm)
- Six-filter VIS model (405, 450, 492, 545, 600, and 630 nm)
Substitute filters in the range of 405 nm – 750 nm are available on special order
models.
Stat Fax 4200 accepts all standard microplates. Trays containing microstrips may also be read
whether they are 12 wells in length, 8 wells or even partial strips.
The software allows the operator to create, edit and store assays. Standard
curves are also stored in this memory. Test protocols remain stored until either changed or
deleted by the user.
TheStat Fax 4200’s optical system provides an economical and low maintenance design which reads 8 wells simultaneously. A 96 well plate can be read and printed in the absorbance mode in approximately ten seconds. Light from a lamp installed in a sealed light-tight compartment is filtered using a rotating filter wheel. The filtered light is then divided into 8 channels using a fiber optic bundle. The plate carrier precisely positions each row of 8 wells into the optical path for reading. Light passing through the 8 wells is directed to 8 photo-detectors. The filter wheel moves to a second position to read the 8 wells at a second wavelength. Using bichromatic differential absorbance values corrects for optical imperfections in the plastic wells and removes the effects of meniscus and turbidity.
Specifications: |
|
Photometric |
|
Linear Measurement Range: |
0.0 to 4.0 Absorbance Units (A) |
Photometric Accuracy: |
+/- (1% +/- 0.010) 0.0 through 1.5 ABS |
+/- (2% +/- 0.010) 1.5 through 3.0 ABS |
|
Stability: |
Drift of no more than 0.005A in 8 hours |
Light Source: |
Halogen lamp with lamp saver feature |
Standard Wavelengths: |
405, 450, 492, and 630nm. 6-filter: 405, |
450, 492, 545, 600, and 630nm. Filter |
|
options from 405nm to 700nm |
|
Filter Type: |
IAD hardcoat interference, 10nm half bandpass |
Vessel: |
Standard 96-well microplates, or strip trays |
Electronic |
|
Display: |
Interactive touch screen 5.7” (14.5cm) |
LCD, color graphic display |
|
Printer: |
Thermal 64 characters per line, plus graphics |
Power Requirements: |
100-240V AC, 1.2A, 50-60Hz (universal |
input, auto sensing) |
|
Interface: |
USB mouse; USB port used for thumb |
drive interface for firmware updates |
|
(mouse not included; thumb drive not |
|
Speed: |
Reads absorbance of 96 wells in about |
10 seconds |
|
Calculation Modes: |
Factor, Single Standard, Point-to-Point, |
Regression, Cubic Spline, Cut Off Mode |
|
Test Storage: |
Stores 120 tests; stores all parameters |
including wavelengths, calculations, unit |
|
codes, linear and normal ranges, |
|
standard values, test names, and |
|
previous standard curve |
|
Dimensions: |
Approximately 13.5”Wx17”Dx8-1/4”H |
(34.3cmx43.2cmx21cm) weight 12 lbs |
|
(5.5kg) |
STAT FAX 3300 Biochemistry Analyzer
Stat Fax® 3300 is designed for the processing of biochemistries, tube method immune assays, and drug assays from human serum, plasma, or urine. A removable flowcell installs in the read well to provide extremely rapid fluid sampling with low carryover. A builtin vacuum pump and an external waste bottle with level sensing are supplied standard. When the Flowcell is removed, the instrument accepts standard 12 mm round tubes as well as 1 cm square cuvettes. The design of the instrument includes many features to minimize operator error, such as stable factory calibration, automatic zeroing, complete operator prompting, detailed labeling, pre-programmed calculations, visual and audible
feedback, flags and error messages, minimal maintenance requirements. Test parameters, and standard curves are stored in memory for later recall. The Stat Fax® 3300 will store up to 120 tests in memory to be recalled for later use and allows for creation of Levey-Jennings plots for QC. In addition, it will store 512 Patient Results, 512 Control Results, 20 Patients on Worklist, and 15 tests per patient.
SPECIFICATIONS: |
|
Photometric |
|
Linear Measurement Range: |
0.0 to 3.5 (flow-cell mode) |
|
|
Photometric Accuracy: |
+/- (1% +/- 0.010) 0.0 through 1.5 ABS |
+/- (2% +/- 0.010) 1.5 through 3.0 ABS |
|
|
|
Stability: |
Drift of no more than 0.005A in 8 |
hours/bichromatic |
|
|
|
Light Source: |
Tungsten Halogen, 10 Watt, with |
automatic lamp saver |
|
|
|
Standard Wavelengths: |
340, 405, 505, 545, 580, and 630nm |
alternate filters available from 330 to |
|
750nm; an eight position filter wheel is optional |
|
|
|
Filter Type: |
IAD hardcoat interference, 10nm half |
Bandpass |
|
|
|
Tube Size: |
12mm round is standard |
|
|
Minimum Sample Volume: |
1mL for 12mm round tube |
250uL for flowcell |
|
|
|
Display: |
240x128 Graphic LCD w/ Backlight |
|
|
Printer: |
Thermal dot matrix with graphic capability |
Power Requirements: |
Auto-Switching Power Supply |
|
|
Voltage source: |
90 – 264 VAC |
|
|
Certifications: |
CE |
|
|
Speed: |
Reads, calculates and prints results, 3 |
seconds per tube |
|
|
|
Calculation Modes: |
Factor, Single Standard, Point-to-Point, |
Regression, Index Mode |
|
|
|
Test Storage: |
Stores 120 tests. Stores all parameters |
including wavelengths, calculations, unit |
|
codes, linear and normal ranges rate |
|
timing, standard values, test names, and |
|
previous standard curve. |
|
|
|
Dimensions: |
40cm (L) x 37 cm (W) x 14 cm (H) lid |
closed (30 cm lid opened), 14 lbs (6.4 kg) |
Lumate Microplate Luminometer
LuMate is a compact microplate glow luminometer. Its streamlined design with minimal footprint offers superb optics to fit any size lab bench. LuMate teams up with your PC to provide full access to high level software for curve fitting, reporting, and data storage to meet the requirements of modern laboratories. Instrument and software come ready to "plug and play" with your PC.
Easy & Automatic
Simply select an assay from the stored menu and load the plate. LuMate automatically reads the plate, precisely measuring and reporting the light output from each well. LuMate runs hormones and many other applications, with on-board calculations for point to point, linear and log regressions, and log logit modes. A built in reference assures continuous calibration.
Specifications
Optical | |
Detection Mode | Glow Luminescence |
Sensitivity/Detection Limit | HRP 1 X 10-18 moles, ALP 1 X 10-21 moles |
Linear Dynamic Range | 106 RLU |
Cross talk | Less than 2.5 X 10-4 |
Detector | Photomultiplier (PMT) |
Spectral Response Range | 300-650 nm |
Peak Wavelength | 400 nm |
Vessel | 96 wells in strip tray or plate |
Electronic | |
PC connection | USB port |
Microprocessor | eZ80 |
Plate Transport | Stepper motor |
Power Requirements | 100V-250 AC, 50-60 Hz (auto-sensing) |
Software | |
PC Interface | LuMate Manager Software |
Calculation Modes | Multipoint calibration with Regression or Point to Point curve fit with Curve storage option; Relative Light units |
Additional Features | User-programmable open system with curve plotting and editing Selectable plate formatting with duplicates and end-reading selections Multiple timed reading options Automatic interpretation options Alphanumeric test naming Flags and error messages |
Other | |
Certifications | NRTL listed, CE marked |
Enclosure | All metal enclosure |
Dimensions | 7.5 X 8 X 16 inches (19 X 20.3 X 42 cm); 11 lbs (5 kg) |
STAT FAX 2600 Microwell Plate Washer
The Stat Fax® 2600 is a microprocessor-controlled automatic microplate washer that accepts many types of standard microplates and micro strip trays. The instrument will accept microwells having flat-, round-, or V-bottom configurations. It automatically accommodates partially filled micro strip trays. Plates may be washed in the A to H direction (8 strips of 12 wells each) or in the 1 to 12 direction (12 strips of 8 wells each) depending upon the plate orientation in the carrier and the number of wash probes on the head. Instruments are available with user changeable wash heads. The 8-wash head is standard; 12-wash head is available as optional accessories.
The instrument is fully programmable to provide multistep combinations of dispense, aspirate, combined aspirate/dispense, and timed soak cycles. Each user-programmed test can have up to 20 steps, and the instrument is capable of storing approximately 50 separate tests in non-volatile memory. As a convenience feature, the instrument can be programmed to automatically perform a rinse operation at a particular time of day. The instrument may also be used in the direct mode whereby wash operations are selected via the built-in keypad. A feature allowing user-assigned well depth may also be used, if preferred to the automatic well sensing feature. For volumes larger than the capacity of the wells, or to reduce bubbles, a top-wash feature is included so the wash solution may be aspirated off the top as it is being dispensed.
In addition to the 8-probe combination dispense/aspirate wash head, each instrument is supplied with wash, rinse, and waste bottles utilizing integral electronic level sensors, and an aerosol shield. A stainless steel bottle rack is available as an optional accessory.
Specifications:
Physical: |
8/12 probe microplate transport accepts flat, |
round, or V-bottom wells, plates & strip trays; |
|
8 probe aspiration and dispense head (12 probe |
|
wash head optional) |
|
Stainless steel plate bed |
|
Transparent acrylic aerosol shield |
|
Dimensions: |
13.5" W x 16" D x 7.5" H (34.3 cm W x 40.6 cm D x 19 cm H) |
Weight 18.5 lbs (8.39 kg) |
|
Bottle Assembly: |
One each Wash, Rinse and Waste bottles with |
electronic level sensing on all bottles (2 Wash |
|
Bottle option available); 13.5" W x 5.5" D x 10.5" |
|
H ( 34.3 cm W x 14 cm D x 26.7 cm H) |
|
Performance: |
|
Residual (double aspiration): |
3 μl per well |
Dispense precision: |
3% C.V. across 96 wells |
Dispense accuracy: |
Mean volume ± 3% from reference |
Test Storage: |
Approximately 50 |
CappWash plate washer is an ideal elisa plate washer for small scale work. Simple, compact and inexpensive. Fitting into even the tightest budget, Capp plate washer is a perfect alternative to dependence on department washers for washing micro plates and strips. Capp elisa plate washer works most effectively with a vacuum source.
Capp elisa plate washer requires no programming nor electrical wiring connections. It is made of a high-grade stainless steel and polypropylene, making it fully autoclavable and highly resistant to aggressive chemicals.
The unique Two-in-One Design of Capp elisa plate washer gives each tube 2 functions - delivery of the washing solution to the well and aspiration of the used solution back to the waste collection bottle. This is possible as each tube of Capp elisa plate washer consists of an inner tube that releases the distilled water washing solution into the wells for rinsing while the outer tube vacuums away the liquid upon completion of the washing procedure.
The washing process with Capp plate washer is as simple as it can be: Simply lower the tubes into the well then push the knob to fill and release the knob to empty. Now repeat for the desired amount of washings and move on to the next row.
Capp elisa plate washer is suitable for all well types. The plate washer can be set to the desired depth very easily by simply adjusting the two screws found on either side of the tubes
- Easy to operate
- Simple & robust design
- Manual ELISA plate washer
- Easy to operate
- Simple and robust design
- Fully autoclavable
W-12 - CappWash plate washer 12-channel
W-12KIT-115V - CappWash Kit including W-12, WP-115V, WB-1, WB-3, WB-4, and W-1000 (3 meters)
CAPPWash Kit includes 12-channel plate washer, vacuum pump, wash-collection bottles and tubing. CAPPWash Microplate Washer is the ideal tool for small scale immune assays. Fitting into even the tightest budget, CAPPWash is a perfect alternative to dependence on department washers for washing microplates and strips.
W-16KIT-115V- CappWash Kit including W-16, WP-115V, WB-1, WB-3, WB-4, and W-1000 (3 meters)
W-16KIT-230V - CappWash Kit including W-16, WP-230V, WB-1, WB-3, WB-4, and W-1000 (3 meters)