View:


Please email tech@midsci.com or call 800-227-9997 to request a quote.


Airstream® Class II Type A2  Biosafety Cabinet, AR2 Models

 

The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet

 

Zero Volt Relay Contact to turn ON/OFF exhaust blower and signal the building alarm

 

Rocker Switches and Pressure Gauge

  • Easy-to-use switches
  • Displays filter loading status
  • Manually adjustable UV timer

Adjustable UV Timer

  • Easily adjustable to desired minutes or hours
  • Prolongs UV lamp life, for not turning it ON overnight

One-Piece Interior Wall

  • Double-layer side walls with negative pressure
  • Easy-to-reach service fixture and outlets
  • Large radius corner for easy cleaning

Dished Work Tray

  • Contains spillage
  • Angled edge for easy cleaning
  • V-shaped grille to prevent blocking

Raised Ergonomic Armrest

  • Helps prevent grille blocking
  • Comfortable working posture

Removable Paper Catch

  • Easy-to-clean
  • Optional pre-filter can be fitted

Airflow Sensor

  • Monitors real-time airflow for safety
  • Alerts the user if airflow is insufficient

Energy-efficient DC ECM Blower

  • The leading energy-efficient Class II Type A2 Biosafety Cabinet in the world with 70% energy savings compared to AC motor
  • Stable airflow despite building voltage fluctuations & filter loading
  • Standby mode to further reduce power consumption by 60%

ULPA Filter

  • 10x Filtration efficiency of HEPA filter
  • Creates ISO Class 3 work zone instead of industry-standard ISO Class 5
  • Same 10 years filter life and replacement cost as HEPA filters

Dynamic Chamber™

  • Blower plenum and side walls are surrounded by negative pressure
  • Prevents contaminants from escaping outside
  • Steel plenum with Isocide™ _coating, instead of flexible bag plenum, to prevent contamination leak

Angled Sash

  • 10° angled front to optimize user comfort, reduce glare, and maximize reach into the work area

ISOCIDE™ Powder Coat

  • Silver-ion-impregnated powder coat
  • Inhibits microbial growth to improve safety
  • Prevents the plenum from becoming a biohazard landfill

 

 

Item#:
ASAIRSTRMAR2

CelCulture® CO2 Incubators

  • Contamination control with long life ULPA filters and 90°C moist heat decontamination cycle.
  • Direct heat & air jacket design with gentle yet effective forced convection.
  • Intuitive interfaces and intelligent data and event logger.

The CelCulture® CO2 Incubator is designed and manufactured using the accumulated expertise and knowledge that Esco has developed with over 35 years of world class equipment for laboratory usage. Designed with sample safety, energy efficiency and user-friendliness in mind, the system achieves precise parameter controls, highly effective contamination control and intuitive user interfaces all--supported by Esco's solution-based sales and service representatives worldwide.


Key Benefits

  • CelSafe Contamination Control System provides unparalleled protection to your precious samples
  • SteriSafe ULPA filtration enables the chamber air to be maintained at ISO class 5 conditions.
  • All input gases are filtered by in-line filters before they enter the chamber to remove impurities and contaminants.
  • The incubator's main body is made from electro-galvanized steel with Esco's unique ISOCIDE antimicrobial coating.
  • SwiftCon moist heat 90°C decontamination cycle operates overnight to eradicate contamination in the unlikely event it occurs. At the end of the cycle, the chamber is dry and ready to use.
  • CelAlert Alarm System reminds users of important tasks needed to protect their cultures
  • CO2 tank depletion reminder in addition to CO2 tank-low alarm.
  • ULPA-reminder will alert user to replace ULPA filter


VivoCell Precise Temperature, CO2 Control and High Humidity

  • Best uniformity and control among available CO2 Incubators
  • Fast CO2, temperature, and humidity recovery without overshoot.
  • Direct heat design for rapid recovery, with 8 heaters grouped into 3 zones.
  • Air jacket provides isolation against ambient temperature fluctuations.
  • Filtered air circulates across water pan accelerating humidifying process and flows gently around culture plates, causing no disturbance to cell culture.
  • Blower automatically stops when door is opened, to minimize mixing of chamber and room air. VentiFlow forced convection. accelerates recovery of chamber air to ISO Class 5 Cleanliness after door closing to prevent contamination.


Easy-to-Clean

  • Chamber is made of stainless steel chamber with rounded corners enabling efficient and rapid cleaning.
  • Ductwork, plenums and shelves are removable without tools for faster and easier operator maintenance.
  • Glass door and inner gasket are removable without tools
Item#:
ASCELCULTURECO2

Rephile NuZar Q

 

NuZar water system set, Q produces ultrapure water (Type I water) from RO, distilled or deionized water. The quality of ultrapure water meets or exceeds ASTM, CLSI, CAP, and ISO Type I water standards.


The NuZar water purification systems are compact and powerful. They are specifically designed for laboratories that demand a balance between cost of ownership and exceeding their purified water requirements. 


The system is CE/RoHS certified. RephiLe provides full documents support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.


General Specifications
Operating voltage24 VDC
Input voltage100 - 240 VAC
Main system power< 190 W

 
Feed Water Requirements
Feed waterEDI water, RO water, Distilled water, Deionized water
Operating temperature5 – 35 °C
Feed water pressure0 - 1 bar (0 - 15 psi)*
  
Product Water Quality
Ultrapure water dispensing rateUp to 2 L/min
Ultrapure water resistivity (@25°C)18.2 MΩ­·cm
Ultrapure water TOC< 5 ppb**
Particles in ultrapure waterNo Particles with size > 0.22 μm
(with a 0.2 μm final filter or RephiBio filter)
Microorganisms in ultrapure water< 0.01 cfu/ml (with a 0.2 μm final filter or RephiBio filter)
Pyrogens (endotoxins) in ultrapure water< 0.001 Eu/mL (with a RephiBio filter)
RNase in ultrapure water< 0.5 pg/mL (with a RephiBio filter)
DNase in ultrapure water< 10 pg/mL (with a RephiBio filter)
  
Dimensions & Weight
Dimensions (W x D x H)414 x 310 x 624 mm (16.3 x 12.2 x 24.5 in)
Weight (Approximate)Net 18 kg  |  Gross 27 kg
**When TOC Level of feed water is < 50 ppb. 

*It’s recommended to use a pressure regulator if feed water pressure is above 15 psi (1 bar)

 

Item#:
ASREPHILENUZARQ
View: