Lab Ovens and Incubators

Your work is important. That’s why every incubator and laboratory oven from MIDSCI is reliably engineered and stringently tested.

MIDSCI has the incubator oven for your research applications. Manufactured by respected names like Labnet, Shel Lab, Lab Companion, BINDER, Benchmark, and more, these lab incubators deliver performance you can rely on. 
  
Features include excellent temperature uniformity and accuracy, rapid temperature recovery after opening, and over-temperature protection. 
  
And if you’re looking for a lab oven, then you’ll have a wide selection to choose from. 
  
We have gravity and forced convection ovens, hybridization ovens, and vacuum ovens. 

MIDSCI also provides two options for hybridization ovens with shaking: Shake ‘n’ Bake hybridization oven from Boekel and Problot 12S hybridization oven from Labnet.

|◀ 13 - 24 of 56 ▶|
View:
Economy Gravity Convection Ovens
  • Used for drying, baking, sterilizing, evaporating, heat treating, annealing and testing
  • Quick run-up and recovery times
  • Exterior has a hard, scratch-resistant hammer finish on a heavy steel double-wall construction
  • Temperature is controlled by an automatic hydraulic or a bi-metal thermostat
  • UL and CSA recognized
  • Warranty: 18 months

Order #

Capacity (Cu. Ft.)

Max Temp
(°C)

Wattage

Amps

Inside Dimensions (in.)(WxHxD)

Outside Dimensions (in.)(WxHxD)

Shipping Weight (lbs.)

10GC

0.7

225

600

5.22

12x10x10

14x17x12

44

20GC

1.27

225

800

6.95

13x13x13

15x21x15

61

30GC

2.0

225

1200

10.43

18x16x12

20x25x14

78

40GC

3.0

225

1600

13.91

18x21x14

20x30x16

94

Item#:
ASGRVCONOV1

The HB-500 Minidizer is a personal, desktop hybridization oven that is ideal for use in laboratories with low use and limited space requirements. Microprocessor controls allow for consistent, repeatable results and the chamber interior is stainless steel with a 3/8" beta-blocking acrylic cover. The cover swings down for direct access to the bottle carousel, which can be removed from the chamber for the easy insertion or removal of bottles.

In addition to the hybridization oven features mentioned above, the Crosslinker In 95-0031-01 features:
·  Preset and manual controls for ultraviolet or time exposures
·  Preset exposure delivers 120,000 microjoules or five minutes of exposure
·  Shortwave 254nm, 8 watt, ultraviolet tubes
·  Microprocessor measures and controls UV output, ensuring maximum energy efficiency
·  Large LED display continuously displays time or energy settings
·  Tactile membrane switch keypad
·  Window on the door allows viewing of the process yet blocks out the UV radiation
·  Dimensions: 17.5W x 24H x 15D in. (445 x 610 x 381 mm)
·  1 year warranty


Variable Speed

10 to 18 RPM

Heating Element

1200 Watts

Operation Range

Ambient to 99.9oC

Temperature Controller Accuracy

+0.1OC

Temperature Display

LED

Temperature Stability

Inside Oven: +0.3oC to 68oC
Inside Bottles: +0.1oC to 68oC

Temperature Uniformity

Inside Oven: +0.1oC to 68oC
Inside Bottles: +0.1oC to 68oC

Interior Dimensions

14"W x 10.75"H x 10.75:D 
(356 x 273 x 273mm)

Bottle Capacity

Twenty (20) 35 x 150 mm
Ten (10) 35 x 300 mm
Four (4) 70 x 300 mm 
(with separate Carousel Kit)

Power

12V AC/DC from 115V/60Hz or 230V/50Hz

Crosslinker Specifications (HL-2000 HybriLinker only)

Pre-set or user-selected UV energy or UV time exposure settings

Maximum UV energy setting of 999,900 microjoules per cm2

LED displays time or energy

Internal interlocking safety system

Tactile membrane switch keypad

Five 8-watt, 254nm shortwave dual bipin discharge type tubes

Interior Dimensions: 11"W x 3.7"H x 11.5" D (280 x 95 x 292mm)

Item#:
ASHYBRIOVEN3
Operational Features Microprocessor PID control Simple calibration and auto-tuning function Temperature control: 15°C above ambient to 220°C Delayed ON/OFF digital timer range: 1 min ~ 99 hr 59 min Intuitive and easy-to-operate control panel with bright LED display (1°C resolution) and touch-sensitive keypad High temperature limit setting and open door alert Convenient presetting function for 3 most commonly used temperature settings Corrosion-resistant incoloy sheath heating element and stainless steel interior Adjustable dual slide vents for controlling inner vapor circulation (diameter: 38mm/1.5") Model ON-01E ON-11E ON-21E Chamber Vol (L/cu ft) 52 / 1.8 100 / 3.5 150 / 5.3 Temp Range(°C/°F) Amb. +15 to 220 / Amb. +27 to 428 Fluctuation1)(±°C/°F)at 100°C 0.3 / 0.54 0.4 / 0.72 0.5 / 0.9 Variation1)(±°C/°F)at 100°C 6.5 / 11.7 4.1 / 7.38 7.3 / 13.14 Dimension Interior dimensions (W x D x H) (mm/inch) 375x370x370 / 14.8x14.6x14.6 455x430x510 / 18.0x17.0x20.0 585x460x555 / 23.0x18.1x21.9 Exterior dimensions (W x D x H) (mm/inch) 530x535x737 / 20.9x21.1x29.0 610x595x877 / 24.0x23.4x34.5 740x625x922 / 29.1x24.6x36.3 Net weight(Kg/lbs) 34 / 75 46 / 101.4 59 / 130 Electrical Requirements (230V) 50/60Hz, 4.3A 50/60Hz, 6.0A 50/60Hz, 7.4A Cat. No. AAH15015K AAH15025K AAH15035K Electrical Requirements (120V) 50/60Hz, 6.7A 50/60Hz, 8.3A 50/60Hz, 10.0A Cat. No. AAH15016U AAH15026U AAH15036U 1) Technical data (according to DIN 12880)
Item#:
ASNATCONOVEN

BENEFITS

  • Uniform drying conditions thanks to APT.line technology
  • Identical test conditions throughout the chamber interior independent of sample size and quantity
  • Outstanding thermal insulation saves operation costs

IMPORTANT CHARACTERISTICS:

  • Temp Range: room temperature plus 5 °C to 300 °C
  • APT.line preheating chamber technology
  • Free convection
  • Adjustable exhaust air flap
  • Controller with timer functions
  • 2 chrome-plated racks
  • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
  • Other voltages available upon request.

 

Technical Data of the Series ED

9010-0192

9010-0334

9010-0336

Description

ED 23

ED 56

ED 115

Basic data

Housing dimensions not incl. fttings and connections

20

57

114

W x H x D [mm]

435 x 495 x 520

560 x 625 x 565

710 x 735 x 605

Interiors dimensions W x H x D [mm]

222 x 330 x 300

360 x 420 x 380

510 x 530 x 425

Performance Data Temperature

Temp Range ... [°C] above ambient temperature to [°C]

300

15-300

8-300

Temperature uniformity at 150 °C [± K]

2.8

2.5

2.0

Temperature fluctuation at 150 °C [± K]

0.5

0.4

0.4

Heating-up time to 150 °C [min]

28

45

60

Recovery time after 30 seconds door open at 150 °C [min]

28

25

20

Energy consumption at 150 °C [Wh/h]

180

250

Item#:
ASOVEN

The CE Oven Series incorporates the Sure Load shelf system, triple wall construction, easy to read microprocessor controls. Adjust the air exhaust from the chamber without putting your fingers near the heat source. Even at temperatures of 225°C the outer skin of this unit meets all CE requirements, meaning your application will stay hot but your workspace will not. The CE series ovens are CE approved.

This gravity convection oven provides a degree of uniformity comparable to most forced air ovens on the market. The 99 min 59 hr digital timer has an independent control so its use is optional. Once the timer expires the power is cut to only the heating elements. The CE family is our lastest installment of a product of Constant Thinking.

These units include:

  • Sure Load Shelf Design
  • Non-Tip Shelves
  • Microprocessor Controls
  • Suberb Temperature Control
  • Cool Touch Damper
  • Digital Timer to 99hr and 59 min
  • CE Approved
  • Warranty: 2 years

Specifications:

CE3G

CE5G

Chamber Capacity (cu.ft.):

3.4

5.4

Temp Range:

Ambient +15°C to 240°C

Ambient +15°C to 240°C

Temp Uniformity:

±2.0°C at 110°C

±2.0°C at 110°C

Interior Dimensions
(WxDxH) inch.

16.5 x 19.5 x 16.5

21 x 19.5 x 21

Exterior Dimensions
(WxDxH) inch.

25.5 x 26.8 x 33.5

30 x 26.8 x 38

Shelves:

2 supplied (8 max)

2 supplied (8 max)

High Limit Control:

yes

yes

Shipping Weight:

160 lbs.

248 lbs.

Item#:
ASGRVCONOV

SHEL LAB Basic CO2

Water-Jacketed Incubator,

The Model SCO6WE was designed and manufactured to accommodate tight budgets, while maintaining the fundamental needs of quality and precision. These units have PID microprocessor controllers, a heated outer door and a tempered-glass inner door. They provide exceptional temperature uniformity, while minimizing cold spots that lead to condensation and ultimately, contamination. Temperature Range Ambient + 8°C t°C. Temperature Uniformity ± 0.2°C at 37°C.

Although they do not have a humidity display, the extremely stable temperature environment maintains constant humidity through evaporation at 95%. Double wall construction reduces this unit's footprint, so they fit in tight spaces as well as tight budgets.

The audible/visual alarms for temperature and CO2 respond to out-of-tolerance conditions. They offer an independent overtemperature safety control to protect samples from overheating, and an optional CO2 tank switch/alarm to prevent prematurely exhausting the gas supply. Features include:

  • Infrared CO2 Sensor
  • Heated Outer Door
  • Independent Overtemperature Protection
  • Quick Clean Shelf System
5 Year Limited Warranty

 

Specifications:

SCO6WE

Chamber Capacity:

6.0 cu.ft

Temp Range:

Ambient + 8°C to 60°C

Temp Uniformity:

+/- 0.2°C at 37°C.  

CO2 Sensor

Infrared (IR)

CO2 Range:

0-20%

CO2 Recovery Rate:

< 5 minutes

Interior Dimensions
(WxDxH) inch.

20.2 x 19.7 x 25.2 (51.4 x 50.1 x 64.1 cm)

Exterior Dimensions
(WxDxH) inch.

26.0 x 26.3 x 40.3 (66.0 x 66.7 x 102.2 cm)

Shelves:

3 supplied (16 max)

Net weight/Shipping Weight:

245/310 lbs.

Item#:
SCO6WE
Your Price:
6210.00
Each

SHEL LAB CO2 High Heat

Decontamination Incubator,

Model SCO6AD features the ultimate in contamination control. This unit is ideal for cell culture labs where contamination can result in significant losses of both time and money. The SCO6AD boasts the most effective decontamination cycle on the market  dry heat for two hours at 180°C. This time/temperature relationship satisfies all global standards for decontamination. Plus, the overall decontamination cycle (heat up to cool down) is the fastest on the market, so users will have minimal downtime on their SCO6AD. In addition, there is no need to remove sensitive components prior to running the decontamination cycle.

Standard Design Features:

  • Infrared (IR) CO2_Sensor is extremely quick to recover CO2 levels after door openings and ensures superior pH stability.
  • Unique air jacket design provides excellent temperature uniformity of +/-0.25°C at 37°C.
  • Humidity levels maintained through evaporation of up to 95%
  • Data logging capabilities
  • Designed to minimize contamination; incudes:
  • The fastest high heat decontamination cycle on the market without having to remove critical components
  • Heated door to ensure superior temperature uniformity and also reduce the potential for condensation to form on the inner glass door
  • Durable stainless steel chamber with coved corners for easy cleaning
  • Exclusive heated copper CO2 inlet not only promotes temperature uniformity but also prevents moisture from being introduced into the chamber
  • Copper shelving option
  • Autoclavable shelving system
  • Industry best warranty  5 years parts and labor in the USA, 7 years on the IR sensor

EXTERIOR DIMENSIONS (W × D × H)

28.5 × 30.8 × 39.5 
(724 mm × 783 mm × 1004 mm)

INTERIOR DIMENSIONS (W × D × H)

20.2 × 20 × 25.5 
(513 mm × 508 mm × 648 mm)

VOLUME

5.9 cu.ft. (167 L)

SHELF DIMENSIONS (W × D)

19.1 × 19.1 (485 mm × 485 mm)

UNIT WEIGHT

238 lbs (108 kg)


INTERIOR METAL

300 SST

EXTERIOR METAL

Painted Cold Roll Steel


OPERATING TEMPERATURE RANGE

Amb +5C - 50C

TEMPERATURE UNIFORMITY - MIDRANGE

0.25 °C

TEMPERATURE STABILITY - MIDRANGE

0.1 °C


CONTROLLER TYPE

Digital

DISPLAY RESOLUTION

0.1 °C


POWER VOLTAGE , FREQUENCY AND CURRENT

110-120 VAC, 50/60 Hz, 12.0 Amps

MAX HVAC LOAD

2354 BTUs/hr


SAFETY CERTIFICATIONS

UL 61010-1EN 61010-1CSA 61010-1, CE

Item#:
SCO6AD
Your Price:
7367.00
Each

SHEL LAB CO2 Water-Jacketed

Incubator, 5.0 cu.ft.,

Model SCO5W water jacketed CO2 incubator and is an ideal unit for cell culture applications. It provides a precisely controlled, accurate, pure environment throughout the culturing process. SHEL LAB CO2 incubators are designed to provide the uniform temperatures and highly stable CO2 environments that are necessary to prevent shocks to cells. Also available in a benchtop 1.5 cu.ft./42 L size (Model SCO2W), and SCO5W units can be stacked with the use of a stacking rack (PN 9751223)

Standard Design Features:

  • Infrared (IR) CO2_Sensor is extremely quick to recover CO2 levels after door openings and ensures superior pH stability
  • Unique water jacket design provides excellent temperature uniformity of +/-0.2°C at 37°C
  • Humidity levels, maintained through evaporation, of up to 95%
  • Data logging capabilities
  • Designed to minimize contamination; includes:
  • Patented copper-caged HEPA filter
  • Heated door to ensure superior temperature uniformity and also reduce the potential for condensation to form on the inner glass door
  • Durable stainless steel chamber with coved corners for easy cleaning
  • Exclusive heated copper CO2 inlet not only promotes temperature uniformity but also prevents moisture from being introduced into the chamber
  • Copper shelving option
  • Autoclavable shelving system
  • Industry best warranty  5 years parts and labor in the USA, 7 years on the IR sensor

MODEL

SCO5W

PART ID

SCO5W


EXTERIOR DIMENSIONS (W × D × H)

26 × 25.5 × 40.3 
(661 mm × 648 mm × 1024 mm)

INTERIOR DIMENSIONS (W × D × H)

19.3 × 19.8 × 23 
(490 mm × 503 mm × 584 mm)

VOLUME

5.1 cu.ft. (144 L)

SHELF DIMENSIONS (W × D)

19.1 × 19.1 (485 mm × 485 mm)

UNIT WEIGHT

254 lbs (115.2 kg)


INTERIOR METAL

300 SST

EXTERIOR METAL

Painted Cold Roll Steel


OPERATING TEMPERATURE RANGE

Amb +5C - 60C

TEMPERATURE UNIFORMITY - MIDRANGE

0.2 °C

TEMPERATURE STABILITY - MIDRANGE

0.1 °C


CONTROLLER TYPE

Digital

DISPLAY RESOLUTION

0.1 °C


POWER VOLTAGE , FREQUENCY AND CURRENT

110-120 VAC, 50/60 Hz, 5.0 Amps

MAX HVAC LOAD

2137 BTUs/hr


SAFETY CERTIFICATIONS

UL 61010-1EN 61010-1CSA 61010-1, CE

Item#:
SCO5W
Your Price:
7458.00
Each

Stainless Steel CO2 incubator

170L, IR Sensor, Control, ULPA

CelCulture® CO Incubators


The CelCulture® CO Incubator is designed and manufactured using the accumulated expertise and knowledge that Esco has developed with over 35 years of world class equipment for laboratory usage. Designed with sample safety, energy efficiency and user-friendliness in mind, the system achieves precise parameter controls, highly effective contamination control and intuitive user interfaces all--supported by Esco's solution-based sales and service representatives worldwide.

  • Contamination control with long life ULPA filters and 90°C moist heat decontamination cycle.
  • Direct heat & air jacket design with gentle yet effective forced convection.
  • Intuitive interfaces and intelligent data and event logger.

KEY BENEFITS

  • CelSafe Contamination Control System provides unparalleled protection to your precious samples
    • SteriSafe ULPA filtration enables the chamber air to be maintained at ISO class 5 conditions.
    • All input gases are filtered by in-line filters before they enter the chamber to remove impurities and contaminants.
    • The incubatorâs main body is made from electro-galvanized steel with Escoâs unique ISOCIDE antimicrobial coating.
    • SwiftCon moist heat 90⁰C decontamination cycle operates overnight to eradicate contamination in the unlikely event it occurs. At the end of the cycle, the chamber is dry and ready to use.
  • CelAlert Alarm System reminds users of important tasks needed to protect their cultures
    • CO tank depletion reminder in addition to CO tank-low alarm.
    • ULPA-reminder will alert user to replace ULPA filter

VivoCell Precise Temperature, CO Control and High Humidity

  • Best uniformity and control among available CO Incubators
    • Fast CO, temperature and humidity recovery without overshoot.
    • Direct heat design for rapid recovery, with 8 heater grouped into 3 zones.
    • Air jacket provides isolation against ambient temperature fluctuations.
  • Filtered air circulates across water pan accelerating humidifying process and flows gently around culture plates, causing no disturbance to cell culture.
  • Blower automatically stops when door is opened, to minimize mixing of chamber and room air. VentiFlow forced convection. accelerates recovery of chamber air to ISO Class 5 Cleanliness after door closing to prevent contamination.

Easy-to-Clean

  • Chamber is made of stainless steel chamber with rounded corners enabling efficient and rapid cleaning.
  • Ductwork, plenums and shelves are removable without tools for faster and easier operator maintenance.
  • Glass door and inner gasket are removable without tools
Item#:
CCL-170B-9
Your Price:
8400.00
Each

Operating features

  • 5°C above room temperature to 70°C
  • Microprocess PID control/ Auto-tuning/ Calibration
  • Digital timer: 1 min to 99 hr 59 min, delayed ON/ OFF
  • Over-temperature limiter/ Door opening alarm
  • 3 different temperature values memorable 
  • Digital LED display (0.1°C resolution) with touch-sensitive keypads
  • RS-232 interface available

    Constructional features

  • Fully insulated dual-wall door with rubber magnetic seal gasket keep setting temperature. 
  • Stackable two high using the stacking kit.(optional)
  • Optimized sample inspection through a tempered inner glass door without affecting chamber temperature.
  • Separable Detachable shelves and rounded inner chamber corners for easy cleaning.
  • Highly durable incoloy heating element with fins that guarantee better radiation.
  • Attach other electric instruments to the inside of the chamber through a side cable port.
  • Cable port allow for control of the amount of airflow in the chamber.
    (dia 38mm/1.5°C, Provided silicon or rubber cap)

     

    Specifications

    Model IB-05G IB-15G IB-25G
    Chamber volume(L/cu ft) 60 / 2.1 102 / 3.6 151 / 5.3
    Temperature Range(°C/°F) Amb. +5 to 70 / Amb. +9 to 158
    Fluctuation1)(±°C/°F)at 37°C
    0.1 / 0.18
    0.1 / 0.18
    0.2 / 0.36
    Variation1)(±°C/°F)at 37°C
    0.6 / 1.08
    0.2 / 0.36
    0.6 / 1.08
    Dimension Interior dimensions
    (W x D x H) (mm/inch)
    400x360x420
    / 15.7x14.2x16.5
    480x410x520
    / 18.9x16.1x20.5
    610x460x540
    / 24.0x18.0x21.3
    Exterior dimensions
    (W x D x H) (mm/inch)
    595x555x745
    / 23.0x22.0x29.0
    675x605x855
    / 27.0x24.0x34.0
    805x655x885
    / 32.0x26.0x35.0
    Net weight(Kg/lbs) 45 / 99 55 / 121 62 / 136
    Electrical Requirements (230V) 50/60Hz, 1.3A 50/60Hz, 2.2A 50/60Hz, 3.1A
    Cat. No. AAH21162K AAH21172K AAH21182K
    Electrical Requirements (120V) 50/60Hz, 2.8A 50/60Hz, 4.6A 50/60Hz, 6.4A
    Cat. No. AAH21166U AAH21176U AAH21186U
    1) Technical data (according to DIN 12880)

     

Item#:
ASCO2AIR3
  • Digital control of temperature and CO2
  • Compact, fits in most biological safety cabinets
  • 20L capacity, accepts bottles & flasks up to 2L
  • Heats & cools (room temp to -10 to 55 ° C)
  • Dual beam infrared CO2 sensor

At only 13 inches wide, the myTemp Mni CO2 incubator is the smallest and most economical for applications requiring g CO2 as control. The small footprint makes it ideal for use inside biological safety cabinets, isolating sensitive cultures or for any other laboratory simply trying to conserve bench space.


With a thick layer of high efficiency insulation surrounding the chamber, the incubator is ideal for transportation of cells. Once power has been disconnected, the incubator maintains temperature levels within 10% of the set parameter for up to an hour AND each unit includes a 12V vehicle power adapter for operating in a car or other similar connection.


Both temperature and CO2 percentage are digitally adjustable and displayed in real time on the large LED control panel, which also features a "Cal" function for easy in-lab calibration of temp or CO2 level. In addition, humidity can be added to the chamber (up to 80%) by inserting included stainless steel humidity reservoir. CO level is constantly monitored using dual beam infrared sensing technology. In the event of a drop in CO2, audible and visual alarms are triggered, notifying end user of error.


Despite its small size, the incubator features a relatively large 20L chamber with capacity for flasks and bottles up to 2L. Two removable perforated stainless steel shelves are included to improve airflow within the chamber.


Technical Specifications:

 

 

 

Temp Range

Ambient -10° to 55 ° C

 

Temp Accuracy

+/- .25 ° C (at 37 °C)

 

Temp Uniformity

+/- .5 ° C (at 37 ° C)

 

Temp Increments

.1 ° C

 

CO Range

0 to 20%

 

CO Sensor

Dual Beam IR

 

CO Accuracy

.1 at 5%

 

Humidity

70 to 80 %

 

Dimensions

Exterior: 13.2 X 14.5 X 18.7 in.

Interior: 10.3 X 9.3 X 12.8 in

Weight

15 lbs (6.5 kg)

 

Capacity

20L or .8 cu.ft.

 

Electrical

100-240V, 50-60 Hz

12V DC

Item#:
ASCO2AIR2

The new C 170 CO incubator has been designed for standard applications in the cell culture laboratory. It provides a reproducible control for the cell well-being parameters while also ensuring the best possible levels of contamination safety in the incubator thanks to its straightforward design. When stacked, it offers 11.8 cubic feet of incubation space and excellent usability.


BENEFITS:

  • Best Uniformity in Class
  • Increased Volume of 5.9 cubic feet
  • Hot Air Sterilization Cycle at 180°C minimizing the risk of contamination
  • Maximum Saturation Without Condensation
  • Stable pH-values thanks to drift-free CO2 IR sensor technology
  • Easy cleaning thanks to seamless, deep-drawn inner chamber

MAIN FEATURES:

    • Temperature range: room temperature plus 7°C to 50°C
    • Humidity range: up to 95 % RH
    • Auto-sterilization with hot air at 180°C
    • Humidification system with condensation protection
    • CO gas-mixing jet with Venturi effect
    • CO sensor with infrared technology
    • Display with 3-digit, 7-segment LEDs
    • Door hinged right or left
    • Tightly-sealed inner door made of tempered safety glass
    • Seamless, deep-drawn inner stainless steel chamber
    • 3 perforated stainless steel shelves
    • Units are stackable with stacking adapter
    • Troubleshooting system with visual and audible alarms
    • Zero-voltage alarm contact

TECHNICAL DATA:

Description

9040-0113*

9040-0116*

Performance Data Temperature

Temperature range 7°C above ambient temperature to [°C]

50

50

Temperature variation at 37°C [± K]

0.3

0.3

Temperature fluctuation [± K]

0.1

0.1

Recovery time after 30 seconds door open at 5 Vol.-% CO2 [min]

5

5

Recovery time after 30 seconds door open at 37 °C [min]

6

6

Performance Data Climate

Humidity range [% RH]

90â¦95

90â¦95

Gas Data - CO2-Data

CO2 range [Vol.-% CO2]

0â¦20

0â¦20

CO2 measurement

IR

IR

Electrical data

Rated Voltage [V]

120

120

Power frequency [Hz]

60

60

Nominal power [kW]

1.1

1.1

Unit fuse [A]

10

10

Phase (Nominal voltage)

1~

1~

Measures - Outer dimensions

Width net [mm/in]

740 /29.16

740 /29.16

Height net [mm/in]

870/34.28

870/34.28

Wall clearance back [mm/in]

100/3.94

100/3.94

Wall clearance sidewise [mm/in]

50/1.97

50/1.97

Measures â Doors

Inner doors

1

1

Unit doors

1

1

Measures - Internal Dimensions

Width [mm/in]

560/22.06

560/22.06

Height [mm/in]

600/23.64

600/23.64

Depth [mm/in]

500/19.7

500/19.7

Measures

Interior volume [L/cu.ft.]

168/5.9

168/5.9

Net weight of the unit (empty) [kg/lbs]

110/243

110/243

Load per rack [kg/lbs]

10/22

10/22

Environment-specific data

Energy consumption at 37°C

90 Wh/h

90 Wh/h

Fixtures

Number of shelves (standard/ maximum)

3/8

3/8

* All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10%. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series.