S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Pall® PTFE
Membrane Disc Filters
- Strong, Chemically Resistant Membranes for Air Monitoring and Sampling in Aggressive Environments
- Low chemical background permits highly sensitive, interference-free determinations.
- Ensures accurate gravimetric determinations with low tare mass.
- Ideal for filtration of gas and/or organic solvents.
We suggest purchasing PR1MA Microtubes.
Contact your rep or email tech@midsci.com for more information.
- Low binding to protect sample integrity
- -80°C to 121°C, 24,000 x g
- 100% Virgin Polypropylene
- Side Gated - No More Sore Thumbs!
- DNase/RNase-Free, non-sterile, natural
Acrylic Serological Pipet Racks
PR-40
- Four angled compartments hold pipettes securely
- Notched shelves allow easy access to shorter pipettes
- Durable ¼-inch acrylic construction
- Flat top for additional storage of pipettors, tips, etc.
- Non-skid rubber feet
- Overall Dimension: 11.75"D x 3.75"W x 16"H
- Compartment Dimensions: 11.5"D x 3.25"W x 3"H
PR-42
- Same features as the PR-40, but twice as big
- Overall Dimension: 11.75"D x 7"W x 16"H
- Compartment Dimensions: 11.5"D x 6.5"W x 3"H
Pall® Biodyne®
Nylon Transfer Membranes
- High sensitivity and low background for enhanced detection and resolution.
- Will not crack, shrink, or tear when subjected to multiple cycles of hybridization, stripping, and reprobing
- Membranes are intrinsically hydrophilic for easy wetting
- Offers superior performance with radioactive (Biodyne B membrane) and non-radioactive (Biodyne A membrane) detection systems
Four Chemistries Provide Versatile Adsorption Properties:
- Biodyne A Membrane - (Amphoteric Nylon 6,6) Membrane zeta potential can be modulated by changes in pH. Ideal for single probe or multiple rehybridizations, and applications where background is troublesome.
- Biodyne B Membrane - (Positively-charged Nylon 6,6) Pore surfaces are populated by a high density of quaternary ammonium groups. Our highest sensitivity nylon membrane for nucleic acid applications.
- Biodyne C Membrane - (Negatively-charged Nylon 6,6) Can be derivatized by coupling reactions through the carboxyl groups on the pore surfaces.
- Biodyne Plus Membrane - (Positively-charged Nylon 6,6 with an extremely high isoelectric point) With certain nonradioactive detection systems, it is more sensitive than Biodyne A membrane while exhibiting lower background than Biodyne B membrane.
Pall® Macrosep® Advance Centrifugal Devices
- Quickly Concentrates Up To 20 mL of Biological Sample
- Rapidly concentrates 20 mL sample volumes to 0.5 mL
- Achieve 50X concentration and > 90% recovery in just minutes
- Low protein-binding Omega™ membrane and polypropylene housing minimize losses due to non-specific binding
- Versatile Omega membrane is available in a variety of MWCOs
- Built-in deadstop prevents spinning to dryness
- Color-coded and laser etched for easy identification
Sibata Volumetric Pipets
- Class A
- Reusable Glass
- Color-Coded with Colored Markings
- Calibrated To Deliver
Aspirating Pipets
- Ideal for aspiration of media and sample waste removal
- Supplied without graduations or plugs
Wire Grid Racks
This unique steel wire rack allows storage and transport. Heat-cured epoxy coating is unaffected by organic solvents, salts, weak acids and weak alkalis.
Temp. Range: -223ºC (-369ºF) to 121ºC (250ºF); Autoclavable
- Standard thermal cycling and qPCR compatible
- Ultra-thin and consistent wall thickness for precise thermal transfer
- Made from 99.9% virgin polypropylene
- Single notch corner
- 335ul well capacity (working capacity dependent on closure method)
- Fits standard thermal cyclers, ABI Real Time PCR 7300, 7500, 7900, qPCR and ABI Sequencing
- Certified DNAse/RNAse and pyrogen-safe
- Thin-wall for consistent heat transfer
- Ultra-low sample evaporation
- Certified DNAse/RNAse, nucleic acid, PCR-inhibitor, and pyrogen-FREE
- Fits the following ABI Cyclers: 7500 Fast, 7900 Fast, 9800 Fast, StepOne Plus, Veriti Fast
Krystal Plates are available for a variety of applications.
- Ideal for routine flourescence, luminescence and scintillation assays
- 384, 96 or 24 well format
- Clear well bottoms allow for reading above or below the plate
- Available tissue culture treated or high binding
- Sleeved plates with lids available for use in robotic systems
- Bar coding available
The Krystal microplates are supplied white for lumines-cence/ fluorescence or black for fluorescence assays. Clear well bottoms allow for use with instruments that read above or below the plate. |
Three formats are avaiable to meet a range of applica-tions: 384 x 120 µl/well, 96 x 350 µl/well and 24 x 3 ml/ well. All can be ordered tissue culture treated. The 24 well plates are also available with a high binding irradi-ated surface. |
Both the 384 well and 96 well plates are supplied in packages of 100 or in an HTS pack that includes 4 sleeves of 25 tissue culture treated plates with lids. The 24 well plates are supplied 68 plates to a pack with the exception of the tissue culture treated plates which are supplied individually wrapped with lids in packages of 56. |
Bar coding is available for all plates upon request. |
Pall® Acrodisc® One Premium Syringe Filters
The new Acrodisc® One and Acrodisc® PSF premium syringe filters combine the benefits of a multi-layered prefiltration device with an automation-certified filter housing.
- Increased surface area for maximizing throughput
- Heat sealed membrane for reduced breakthrough
- Accurate analysis. HPLC certified for low levels of UV-absorbing extractables
- Available in 0.2 µm for UHPLC applications and with GxF (Glass Fiber) pre-filter for difficult to filter samples
- Automation Certified to ensure smooth operation and worry-free performance 24 hours a day in automated workstations
- The Acrodisc® One offers a Universal Membrane for all your analytical filtration requirements
Acrodisc ONE with water wettable PTFE (wwPTFE) has a Next Generation Universal Membrane for all sample types with fast flow rates, low protein binding, and low levels of UV-absorbing extractables. Avoid the expense and inconvenience of keeping a variety of filters on hand, it is a versatile filter for aqueous and aggressive organic solvent-based solutions.
Other Acrodisc® PSF filter membrane options:
- PVDF membrane has excellent compatibility with aggressive acids and alcohols.
- PES membrane is available in a special Ion Chromatography design or with a GxF prefilter.
- Nylon membrane has excellent compatibility with esters, bases, and alcohols, and requires no prewetting.
- Hydrophobic PTFE membrane offers exceptional chemical and temperature compatibility and is ideal for gas, organic solutions, air filtration, or venting.
The Acrodisc® One and Acrodisc® PSF GxF syringe filters provide two to four times the throughput of standard prefilter devices for particulate-laden samples.
For ion chromatography specific syringe filters, look for the Acrodisc® Ion Chromatography Syringe Filters page.
Packaging: Syringe filters packed in cases of 200 are available in four packs of 50 or in an AutoPack™ format. The AutoPack™ format consists of eight tubes with 25 syringe filters stacked on top of each other.